Encoded hydrogel microparticles for high-throughput molecular diagnostics and personalized medicine

Thesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Chemical Engineering, 2012.

Bibliographic Details
Main Author: Chapin, Stephen Clifford
Other Authors: Patrick S. Doyle.
Format: Thesis
Language:eng
Published: Massachusetts Institute of Technology 2013
Subjects:
Online Access:http://hdl.handle.net/1721.1/76565
_version_ 1811088472633507840
author Chapin, Stephen Clifford
author2 Patrick S. Doyle.
author_facet Patrick S. Doyle.
Chapin, Stephen Clifford
author_sort Chapin, Stephen Clifford
collection MIT
description Thesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Chemical Engineering, 2012.
first_indexed 2024-09-23T14:02:41Z
format Thesis
id mit-1721.1/76565
institution Massachusetts Institute of Technology
language eng
last_indexed 2024-09-23T14:02:41Z
publishDate 2013
publisher Massachusetts Institute of Technology
record_format dspace
spelling mit-1721.1/765652019-04-12T21:33:24Z Encoded hydrogel microparticles for high-throughput molecular diagnostics and personalized medicine Chapin, Stephen Clifford Patrick S. Doyle. Massachusetts Institute of Technology. Dept. of Chemical Engineering. Massachusetts Institute of Technology. Dept. of Chemical Engineering. Chemical Engineering. Thesis (Ph. D.)--Massachusetts Institute of Technology, Dept. of Chemical Engineering, 2012. Cataloged from PDF version of thesis. Includes bibliographical references (p. 141-161). The ability to accurately detect and quantify biological molecules in complex mixtures is crucial in basic research as well as in clinical settings. Advancements in genetic analysis, molecular diagnostics, and patient-tailored medicine require robust detection technologies that can obtain high-density information from a range of physiological samples in a rapid and cost-effective manner. Compared to conventional microarrays and methods based on polymerase chain reaction (PCR), suspension (particle-based) arrays offer several advantages in the multiplexed detection of biomolecules, including higher rates of sample processing, reduced consumption of sample and reagent, and rapid probe-set modification for customizable assays. This thesis expands the utility of a novel hydrogel-based microparticle array through (1) the creation of a microfluidic, flow-through fluorescence scanner for high-throughput particle analysis, (2) the development of a suite of techniques for the highly sensitive and specific detection of microRNA (miRNA) biomarkers, and (3) the investigation of new methods for directly measuring biomolecules at the single-cell level. Graphically-encoded hydrogel microparticles synthesized from non-fouling, bioinert poly(ethylene glycol) (PEG) and functionalized with biomolecule probes offer great promise in the development of high-performance, multiplexed bioassays. To extend this platform to applications in high-throughput analysis, particle design was optimized to ensure mechanical stability in high-velocity flow systems, and a single-color microfluidic scanner was constructed for the rapid fluorescence interrogation of each particle's spatially-segregated "code" and "probe" regions. The detection advantages of three-dimensional, probe-laden hydrogel scaffolds and the operational efficiencies of suspension array technology were then leveraged for the rapid multiplexed expression profiling of miRNA. The graphical encoding method and ligationbased labeling scheme implemented here allowed for scalable multiplexing with a simple workflow and an unprecedented combination of sensitivity, flexibility, and throughput. Through the rolling circle amplification of a labeling oligonucleotide, it was possible to further enhance the system's sensitivity and resolve single-molecule miRNA binding events on particle surfaces, enabling the first direct detection of low-abundance miRNA in human serum without the need for RNA extraction or target amplification. Finally, by arraying cells and gel particles in polydimethylsiloxane (PDMS) microwells, it was possible to dramatically improve the particles' target capture efficiency and thereby move closer to a regime in which miRNAs and other biological molecules may be directly detected without target amplification from single cells. by Stephen Clifford Chapin. Ph.D. 2013-01-23T20:22:44Z 2013-01-23T20:22:44Z 2012 2012 Thesis http://hdl.handle.net/1721.1/76565 822567162 eng M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission. http://dspace.mit.edu/handle/1721.1/7582 161 p. application/pdf Massachusetts Institute of Technology
spellingShingle Chemical Engineering.
Chapin, Stephen Clifford
Encoded hydrogel microparticles for high-throughput molecular diagnostics and personalized medicine
title Encoded hydrogel microparticles for high-throughput molecular diagnostics and personalized medicine
title_full Encoded hydrogel microparticles for high-throughput molecular diagnostics and personalized medicine
title_fullStr Encoded hydrogel microparticles for high-throughput molecular diagnostics and personalized medicine
title_full_unstemmed Encoded hydrogel microparticles for high-throughput molecular diagnostics and personalized medicine
title_short Encoded hydrogel microparticles for high-throughput molecular diagnostics and personalized medicine
title_sort encoded hydrogel microparticles for high throughput molecular diagnostics and personalized medicine
topic Chemical Engineering.
url http://hdl.handle.net/1721.1/76565
work_keys_str_mv AT chapinstephenclifford encodedhydrogelmicroparticlesforhighthroughputmoleculardiagnosticsandpersonalizedmedicine