Characterization of an aerodynamic lens for transmitting particles greater than 1 micrometer in diameter into the Aerodyne aerosol mass spectrometer
We have designed and characterized a new inlet and aerodynamic lens for the Aerodyne aerosol mass spectrometer (AMS) that transmits particles between 80 nm and more than 3 μm in vacuum aerodynamic diameter. The design of the inlet and lens was optimized with computational fluid dynamics (CFD) modeli...
Main Authors: | , , , , , , , , , , , , , , , , , , , , |
---|---|
Other Authors: | |
Format: | Article |
Language: | en_US |
Published: |
Copernicus GmbH
2014
|
Online Access: | http://hdl.handle.net/1721.1/85680 https://orcid.org/0000-0001-7002-1681 |
_version_ | 1826212566258417664 |
---|---|
author | Williams, L. R. Gonzalez, L. A. Peck, J. Trimborn, D. McInnis, J. Farrar, M. R. Moore, K. D. Jayne, John T. Robinson, W. A. Lewis, D. K. Onasch, T. B. Canagaratna, M. R. Trimborn, A. Magoon, G. Deng, R. Tang, D. de la Rosa Blanco, E. Prévôt, A. S. H. Worsnop, D. R. Smith, Kenneth A. Timko, Michael T. |
author2 | Massachusetts Institute of Technology. Department of Chemical Engineering |
author_facet | Massachusetts Institute of Technology. Department of Chemical Engineering Williams, L. R. Gonzalez, L. A. Peck, J. Trimborn, D. McInnis, J. Farrar, M. R. Moore, K. D. Jayne, John T. Robinson, W. A. Lewis, D. K. Onasch, T. B. Canagaratna, M. R. Trimborn, A. Magoon, G. Deng, R. Tang, D. de la Rosa Blanco, E. Prévôt, A. S. H. Worsnop, D. R. Smith, Kenneth A. Timko, Michael T. |
author_sort | Williams, L. R. |
collection | MIT |
description | We have designed and characterized a new inlet and aerodynamic lens for the Aerodyne aerosol mass spectrometer (AMS) that transmits particles between 80 nm and more than 3 μm in vacuum aerodynamic diameter. The design of the inlet and lens was optimized with computational fluid dynamics (CFD) modeling of particle trajectories. Major changes include a redesigned critical orifice holder and valve assembly, addition of a relaxation chamber behind the critical orifice, and a higher lens operating pressure. The transmission efficiency of the new inlet and lens was characterized experimentally with size-selected particles. Experimental measurements are in good agreement with the calculated transmission efficiency. |
first_indexed | 2024-09-23T15:26:36Z |
format | Article |
id | mit-1721.1/85680 |
institution | Massachusetts Institute of Technology |
language | en_US |
last_indexed | 2024-09-23T15:26:36Z |
publishDate | 2014 |
publisher | Copernicus GmbH |
record_format | dspace |
spelling | mit-1721.1/856802022-10-02T02:41:22Z Characterization of an aerodynamic lens for transmitting particles greater than 1 micrometer in diameter into the Aerodyne aerosol mass spectrometer Williams, L. R. Gonzalez, L. A. Peck, J. Trimborn, D. McInnis, J. Farrar, M. R. Moore, K. D. Jayne, John T. Robinson, W. A. Lewis, D. K. Onasch, T. B. Canagaratna, M. R. Trimborn, A. Magoon, G. Deng, R. Tang, D. de la Rosa Blanco, E. Prévôt, A. S. H. Worsnop, D. R. Smith, Kenneth A. Timko, Michael T. Massachusetts Institute of Technology. Department of Chemical Engineering Smith, Kenneth A. Timko, Michael T. We have designed and characterized a new inlet and aerodynamic lens for the Aerodyne aerosol mass spectrometer (AMS) that transmits particles between 80 nm and more than 3 μm in vacuum aerodynamic diameter. The design of the inlet and lens was optimized with computational fluid dynamics (CFD) modeling of particle trajectories. Major changes include a redesigned critical orifice holder and valve assembly, addition of a relaxation chamber behind the critical orifice, and a higher lens operating pressure. The transmission efficiency of the new inlet and lens was characterized experimentally with size-selected particles. Experimental measurements are in good agreement with the calculated transmission efficiency. National Science Foundation (U.S.). Small Business Innovation Research Program (Contract 0216220) United States. Environmental Protection Agency (Small Business Innovation Research Program Contract EP-D-05-057) United States. Dept. of Energy. Office of Science (Small Business Innovation Research Program Contract DE-SC0001673) United States. National Aeronautics and Space Administration. Small Business Innovation Program (Contract NNX10CA32C) 2014-03-17T17:52:24Z 2014-03-17T17:52:24Z 2013-11 2013-10 Article http://purl.org/eprint/type/JournalArticle 1867-8548 http://hdl.handle.net/1721.1/85680 Williams, L. R., L. A. Gonzalez, J. Peck, D. Trimborn, J. McInnis, M. R. Farrar, K. D. Moore, et al. “Characterization of an Aerodynamic Lens for Transmitting Particles Greater Than 1 Micrometer in Diameter into the Aerodyne Aerosol Mass Spectrometer.” Atmos. Meas. Tech. 6, no. 11 (November 28, 2013): 3271–3280. https://orcid.org/0000-0001-7002-1681 en_US http://dx.doi.org/10.5194/amt-6-3271-2013 Atmospheric Measurement Techniques Creative Commons Attribution http://creativecommons.org/licenses/by/3.0/ application/pdf Copernicus GmbH Copernicus GmbH |
spellingShingle | Williams, L. R. Gonzalez, L. A. Peck, J. Trimborn, D. McInnis, J. Farrar, M. R. Moore, K. D. Jayne, John T. Robinson, W. A. Lewis, D. K. Onasch, T. B. Canagaratna, M. R. Trimborn, A. Magoon, G. Deng, R. Tang, D. de la Rosa Blanco, E. Prévôt, A. S. H. Worsnop, D. R. Smith, Kenneth A. Timko, Michael T. Characterization of an aerodynamic lens for transmitting particles greater than 1 micrometer in diameter into the Aerodyne aerosol mass spectrometer |
title | Characterization of an aerodynamic lens for transmitting particles greater than 1 micrometer in diameter into the Aerodyne aerosol mass spectrometer |
title_full | Characterization of an aerodynamic lens for transmitting particles greater than 1 micrometer in diameter into the Aerodyne aerosol mass spectrometer |
title_fullStr | Characterization of an aerodynamic lens for transmitting particles greater than 1 micrometer in diameter into the Aerodyne aerosol mass spectrometer |
title_full_unstemmed | Characterization of an aerodynamic lens for transmitting particles greater than 1 micrometer in diameter into the Aerodyne aerosol mass spectrometer |
title_short | Characterization of an aerodynamic lens for transmitting particles greater than 1 micrometer in diameter into the Aerodyne aerosol mass spectrometer |
title_sort | characterization of an aerodynamic lens for transmitting particles greater than 1 micrometer in diameter into the aerodyne aerosol mass spectrometer |
url | http://hdl.handle.net/1721.1/85680 https://orcid.org/0000-0001-7002-1681 |
work_keys_str_mv | AT williamslr characterizationofanaerodynamiclensfortransmittingparticlesgreaterthan1micrometerindiameterintotheaerodyneaerosolmassspectrometer AT gonzalezla characterizationofanaerodynamiclensfortransmittingparticlesgreaterthan1micrometerindiameterintotheaerodyneaerosolmassspectrometer AT peckj characterizationofanaerodynamiclensfortransmittingparticlesgreaterthan1micrometerindiameterintotheaerodyneaerosolmassspectrometer AT trimbornd characterizationofanaerodynamiclensfortransmittingparticlesgreaterthan1micrometerindiameterintotheaerodyneaerosolmassspectrometer AT mcinnisj characterizationofanaerodynamiclensfortransmittingparticlesgreaterthan1micrometerindiameterintotheaerodyneaerosolmassspectrometer AT farrarmr characterizationofanaerodynamiclensfortransmittingparticlesgreaterthan1micrometerindiameterintotheaerodyneaerosolmassspectrometer AT moorekd characterizationofanaerodynamiclensfortransmittingparticlesgreaterthan1micrometerindiameterintotheaerodyneaerosolmassspectrometer AT jaynejohnt characterizationofanaerodynamiclensfortransmittingparticlesgreaterthan1micrometerindiameterintotheaerodyneaerosolmassspectrometer AT robinsonwa characterizationofanaerodynamiclensfortransmittingparticlesgreaterthan1micrometerindiameterintotheaerodyneaerosolmassspectrometer AT lewisdk characterizationofanaerodynamiclensfortransmittingparticlesgreaterthan1micrometerindiameterintotheaerodyneaerosolmassspectrometer AT onaschtb characterizationofanaerodynamiclensfortransmittingparticlesgreaterthan1micrometerindiameterintotheaerodyneaerosolmassspectrometer AT canagaratnamr characterizationofanaerodynamiclensfortransmittingparticlesgreaterthan1micrometerindiameterintotheaerodyneaerosolmassspectrometer AT trimborna characterizationofanaerodynamiclensfortransmittingparticlesgreaterthan1micrometerindiameterintotheaerodyneaerosolmassspectrometer AT magoong characterizationofanaerodynamiclensfortransmittingparticlesgreaterthan1micrometerindiameterintotheaerodyneaerosolmassspectrometer AT dengr characterizationofanaerodynamiclensfortransmittingparticlesgreaterthan1micrometerindiameterintotheaerodyneaerosolmassspectrometer AT tangd characterizationofanaerodynamiclensfortransmittingparticlesgreaterthan1micrometerindiameterintotheaerodyneaerosolmassspectrometer AT delarosablancoe characterizationofanaerodynamiclensfortransmittingparticlesgreaterthan1micrometerindiameterintotheaerodyneaerosolmassspectrometer AT prevotash characterizationofanaerodynamiclensfortransmittingparticlesgreaterthan1micrometerindiameterintotheaerodyneaerosolmassspectrometer AT worsnopdr characterizationofanaerodynamiclensfortransmittingparticlesgreaterthan1micrometerindiameterintotheaerodyneaerosolmassspectrometer AT smithkennetha characterizationofanaerodynamiclensfortransmittingparticlesgreaterthan1micrometerindiameterintotheaerodyneaerosolmassspectrometer AT timkomichaelt characterizationofanaerodynamiclensfortransmittingparticlesgreaterthan1micrometerindiameterintotheaerodyneaerosolmassspectrometer |