EXERCISE-INDUCED ACUTE CHANGES IN SYSTOLIC BLOOD PRESSURE DO NOT ALTER CHOROIDAL THICKNESS AS MEASURED BY A PORTABLE SPECTRAL-DOMAIN OPTICAL COHERENCE TOMOGRAPHY DEVICE

Purpose: To measure choroidal thickness in patients manifesting an acute change in systemic arterial blood pressure using a portable spectral-domain optical coherence tomography device (iVue). Methods: Fifteen patients (15 eyes) undergoing cardiac exercise stress testing were scanned using a portab...

Full description

Bibliographic Details
Main Authors: Alwassia, Ahmad A., Adhi, Mehreen, Zhang, Jason Y., Regatieri, Caio V., Al-Quthami, Adeeb, Salem, Deeb, Fujimoto, James G., Duker, Jay S.
Other Authors: Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science
Format: Article
Language:en_US
Published: Ovid Technologies (Wolters Kluwer) - Lippincott Williams & Wilkins 2014
Online Access:http://hdl.handle.net/1721.1/86408
https://orcid.org/0000-0002-0828-4357
_version_ 1826206620526313472
author Alwassia, Ahmad A.
Adhi, Mehreen
Zhang, Jason Y.
Regatieri, Caio V.
Al-Quthami, Adeeb
Salem, Deeb
Fujimoto, James G.
Duker, Jay S.
author2 Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science
author_facet Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science
Alwassia, Ahmad A.
Adhi, Mehreen
Zhang, Jason Y.
Regatieri, Caio V.
Al-Quthami, Adeeb
Salem, Deeb
Fujimoto, James G.
Duker, Jay S.
author_sort Alwassia, Ahmad A.
collection MIT
description Purpose: To measure choroidal thickness in patients manifesting an acute change in systemic arterial blood pressure using a portable spectral-domain optical coherence tomography device (iVue). Methods: Fifteen patients (15 eyes) undergoing cardiac exercise stress testing were scanned using a portable spectral-domain optical coherence tomography system (iVue). Two scan protocols were used: cross line scan for measuring choroidal thickness and the retina map scan to measure retinal thickness. Each patient was scanned before and within 3 minutes after the stress test. Blood pressure was measured at the same time as the acquisition of the scans. Choroidal thickness was measured from the posterior edge of the retinal pigment epithelium to the choroid–sclera junction at 500-μm intervals up to 1,000 μm temporal and nasal to the fovea. Retinal thickness was measured by an automated software. All choroidal thickness measurements were performed by two independent observers. Results: Fifteen patients (15 eyes) with a mean age of 60.6 (±10.4 years) were scanned. There was a significant increase in systolic but not diastolic pressure after stress testing (P < 0.05). The mean choroidal thickness measurements showed no significant difference before and after exercise stress testing (P > 0.05). In addition, there was no significant difference in retinal thickness before and after stress testing measurements (P > 0.05). Conclusion: There was no change in choroidal thickness or retinal thickness, despite an acute change in the systemic systolic blood pressure induced by exercise.
first_indexed 2024-09-23T13:35:28Z
format Article
id mit-1721.1/86408
institution Massachusetts Institute of Technology
language en_US
last_indexed 2024-09-23T13:35:28Z
publishDate 2014
publisher Ovid Technologies (Wolters Kluwer) - Lippincott Williams & Wilkins
record_format dspace
spelling mit-1721.1/864082022-10-01T15:52:53Z EXERCISE-INDUCED ACUTE CHANGES IN SYSTOLIC BLOOD PRESSURE DO NOT ALTER CHOROIDAL THICKNESS AS MEASURED BY A PORTABLE SPECTRAL-DOMAIN OPTICAL COHERENCE TOMOGRAPHY DEVICE Alwassia, Ahmad A. Adhi, Mehreen Zhang, Jason Y. Regatieri, Caio V. Al-Quthami, Adeeb Salem, Deeb Fujimoto, James G. Duker, Jay S. Massachusetts Institute of Technology. Department of Electrical Engineering and Computer Science Massachusetts Institute of Technology. Research Laboratory of Electronics Fujimoto, James G. Purpose: To measure choroidal thickness in patients manifesting an acute change in systemic arterial blood pressure using a portable spectral-domain optical coherence tomography device (iVue). Methods: Fifteen patients (15 eyes) undergoing cardiac exercise stress testing were scanned using a portable spectral-domain optical coherence tomography system (iVue). Two scan protocols were used: cross line scan for measuring choroidal thickness and the retina map scan to measure retinal thickness. Each patient was scanned before and within 3 minutes after the stress test. Blood pressure was measured at the same time as the acquisition of the scans. Choroidal thickness was measured from the posterior edge of the retinal pigment epithelium to the choroid–sclera junction at 500-μm intervals up to 1,000 μm temporal and nasal to the fovea. Retinal thickness was measured by an automated software. All choroidal thickness measurements were performed by two independent observers. Results: Fifteen patients (15 eyes) with a mean age of 60.6 (±10.4 years) were scanned. There was a significant increase in systolic but not diastolic pressure after stress testing (P < 0.05). The mean choroidal thickness measurements showed no significant difference before and after exercise stress testing (P > 0.05). In addition, there was no significant difference in retinal thickness before and after stress testing measurements (P > 0.05). Conclusion: There was no change in choroidal thickness or retinal thickness, despite an acute change in the systemic systolic blood pressure induced by exercise. National Institutes of Health (U.S.) (Contract RO1-EY11289-23) National Institutes of Health (U.S.) (Contract R01-EY13178-07) National Institutes of Health (U.S.) (Contract R01-EY013516-07) United States. Air Force Office of Scientific Research (Contract FA9550-07-1-0101) United States. Air Force Office of Scientific Research (Contract FA9550-07-1-0014) Massachusetts Lions Eye Research Fund, Inc. 2014-05-05T16:42:10Z 2014-05-05T16:42:10Z 2013-01 Article http://purl.org/eprint/type/JournalArticle 0275-004X http://hdl.handle.net/1721.1/86408 Alwassia, Ahmad A., Mehreen Adhi, Jason Y. Zhang, Caio V. Regatieri, Adeeb Al-Quthami, Deeb Salem, James G. Fujimoto, and Jay S. Duker. “EXERCISE-INDUCED ACUTE CHANGES IN SYSTOLIC BLOOD PRESSURE DO NOT ALTER CHOROIDAL THICKNESS AS MEASURED BY A PORTABLE SPECTRAL-DOMAIN OPTICAL COHERENCE TOMOGRAPHY DEVICE.” Retina 33, no. 1 (January 2013): 160–165. https://orcid.org/0000-0002-0828-4357 en_US http://dx.doi.org/10.1097/IAE.0b013e3182618c22 Retina Creative Commons Attribution-Noncommercial-Share Alike http://creativecommons.org/licenses/by-nc-sa/4.0/ application/pdf Ovid Technologies (Wolters Kluwer) - Lippincott Williams & Wilkins PMC
spellingShingle Alwassia, Ahmad A.
Adhi, Mehreen
Zhang, Jason Y.
Regatieri, Caio V.
Al-Quthami, Adeeb
Salem, Deeb
Fujimoto, James G.
Duker, Jay S.
EXERCISE-INDUCED ACUTE CHANGES IN SYSTOLIC BLOOD PRESSURE DO NOT ALTER CHOROIDAL THICKNESS AS MEASURED BY A PORTABLE SPECTRAL-DOMAIN OPTICAL COHERENCE TOMOGRAPHY DEVICE
title EXERCISE-INDUCED ACUTE CHANGES IN SYSTOLIC BLOOD PRESSURE DO NOT ALTER CHOROIDAL THICKNESS AS MEASURED BY A PORTABLE SPECTRAL-DOMAIN OPTICAL COHERENCE TOMOGRAPHY DEVICE
title_full EXERCISE-INDUCED ACUTE CHANGES IN SYSTOLIC BLOOD PRESSURE DO NOT ALTER CHOROIDAL THICKNESS AS MEASURED BY A PORTABLE SPECTRAL-DOMAIN OPTICAL COHERENCE TOMOGRAPHY DEVICE
title_fullStr EXERCISE-INDUCED ACUTE CHANGES IN SYSTOLIC BLOOD PRESSURE DO NOT ALTER CHOROIDAL THICKNESS AS MEASURED BY A PORTABLE SPECTRAL-DOMAIN OPTICAL COHERENCE TOMOGRAPHY DEVICE
title_full_unstemmed EXERCISE-INDUCED ACUTE CHANGES IN SYSTOLIC BLOOD PRESSURE DO NOT ALTER CHOROIDAL THICKNESS AS MEASURED BY A PORTABLE SPECTRAL-DOMAIN OPTICAL COHERENCE TOMOGRAPHY DEVICE
title_short EXERCISE-INDUCED ACUTE CHANGES IN SYSTOLIC BLOOD PRESSURE DO NOT ALTER CHOROIDAL THICKNESS AS MEASURED BY A PORTABLE SPECTRAL-DOMAIN OPTICAL COHERENCE TOMOGRAPHY DEVICE
title_sort exercise induced acute changes in systolic blood pressure do not alter choroidal thickness as measured by a portable spectral domain optical coherence tomography device
url http://hdl.handle.net/1721.1/86408
https://orcid.org/0000-0002-0828-4357
work_keys_str_mv AT alwassiaahmada exerciseinducedacutechangesinsystolicbloodpressuredonotalterchoroidalthicknessasmeasuredbyaportablespectraldomainopticalcoherencetomographydevice
AT adhimehreen exerciseinducedacutechangesinsystolicbloodpressuredonotalterchoroidalthicknessasmeasuredbyaportablespectraldomainopticalcoherencetomographydevice
AT zhangjasony exerciseinducedacutechangesinsystolicbloodpressuredonotalterchoroidalthicknessasmeasuredbyaportablespectraldomainopticalcoherencetomographydevice
AT regatiericaiov exerciseinducedacutechangesinsystolicbloodpressuredonotalterchoroidalthicknessasmeasuredbyaportablespectraldomainopticalcoherencetomographydevice
AT alquthamiadeeb exerciseinducedacutechangesinsystolicbloodpressuredonotalterchoroidalthicknessasmeasuredbyaportablespectraldomainopticalcoherencetomographydevice
AT salemdeeb exerciseinducedacutechangesinsystolicbloodpressuredonotalterchoroidalthicknessasmeasuredbyaportablespectraldomainopticalcoherencetomographydevice
AT fujimotojamesg exerciseinducedacutechangesinsystolicbloodpressuredonotalterchoroidalthicknessasmeasuredbyaportablespectraldomainopticalcoherencetomographydevice
AT dukerjays exerciseinducedacutechangesinsystolicbloodpressuredonotalterchoroidalthicknessasmeasuredbyaportablespectraldomainopticalcoherencetomographydevice