Economic performance of modularized hot-aisle contained datacenter PODs utilizing horizontal airflow cooling

Thesis: S.M. in Management of Technology, Massachusetts Institute of Technology, Sloan School of Management, 2014.

Bibliographic Details
Main Author: Rabassa, Albert O., III (Albert Oscar)
Other Authors: John E. Van Maanen.
Format: Thesis
Language:eng
Published: Massachusetts Institute of Technology 2014
Subjects:
Online Access:http://hdl.handle.net/1721.1/90248
_version_ 1811084492866060288
author Rabassa, Albert O., III (Albert Oscar)
author2 John E. Van Maanen.
author_facet John E. Van Maanen.
Rabassa, Albert O., III (Albert Oscar)
author_sort Rabassa, Albert O., III (Albert Oscar)
collection MIT
description Thesis: S.M. in Management of Technology, Massachusetts Institute of Technology, Sloan School of Management, 2014.
first_indexed 2024-09-23T12:51:39Z
format Thesis
id mit-1721.1/90248
institution Massachusetts Institute of Technology
language eng
last_indexed 2024-09-23T12:51:39Z
publishDate 2014
publisher Massachusetts Institute of Technology
record_format dspace
spelling mit-1721.1/902482019-04-12T14:44:47Z Economic performance of modularized hot-aisle contained datacenter PODs utilizing horizontal airflow cooling Rabassa, Albert O., III (Albert Oscar) John E. Van Maanen. Sloan School of Management. Sloan School of Management. Sloan School of Management. Thesis: S.M. in Management of Technology, Massachusetts Institute of Technology, Sloan School of Management, 2014. Cataloged from PDF version of thesis. Includes bibliographical references. Evolutionary and revolutionary advances in computational and storage systems have driven electronic circuit densities to unprecedented levels. These high-density systems must be adequately cooled for proper operation and long life expectancy. Cooling solutions must be designed and operated to minimize energy and environmental impacts. Executive decisions are deeply rooted in the technical aspects of the systems and solutions sought. These interdependent solutions seek to maximize system performance while minimizing capital and operating expenditures over the economic life of the data center. Traditional data centers employ a raised floor plenum structure to deliver cooling via perforated floor tiles as the primary delivery system for component cooling. Heated exhaust air exits the equipment and travels upward to warm return plenum structures for subsequent capture and re-cooling. This floor-to-ceiling airflow behavior represents a vertical airflow-cooling paradigm. The resulting airflow may travel 150 feet or more per cooling cycle. A new class of data center cooling utilizes a technique called 'in-row' cooling. This new technique does not require a raised floor plenum, perforated tiles, nor return plenum structures. The airflow travels horizontally from rack-to-rack with respect to cold air delivery and warm air return. Airflow travel is subsequently reduced to only 10 feet per cooling cycle. This thesis will explore the economic benefits and economies of this new airflow paradigm against traditional data centers through the use of measurement and Computational Fluid Dynamic (CFD) modeling software. by Albert O. Rabassa, III. S.M. in Management of Technology 2014-09-19T21:48:29Z 2014-09-19T21:48:29Z 2014 2014 Thesis http://hdl.handle.net/1721.1/90248 890379384 eng CD-ROM contains thesis in .docx format. M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission. http://dspace.mit.edu/handle/1721.1/7582 85 pages application/pdf Massachusetts Institute of Technology
spellingShingle Sloan School of Management.
Rabassa, Albert O., III (Albert Oscar)
Economic performance of modularized hot-aisle contained datacenter PODs utilizing horizontal airflow cooling
title Economic performance of modularized hot-aisle contained datacenter PODs utilizing horizontal airflow cooling
title_full Economic performance of modularized hot-aisle contained datacenter PODs utilizing horizontal airflow cooling
title_fullStr Economic performance of modularized hot-aisle contained datacenter PODs utilizing horizontal airflow cooling
title_full_unstemmed Economic performance of modularized hot-aisle contained datacenter PODs utilizing horizontal airflow cooling
title_short Economic performance of modularized hot-aisle contained datacenter PODs utilizing horizontal airflow cooling
title_sort economic performance of modularized hot aisle contained datacenter pods utilizing horizontal airflow cooling
topic Sloan School of Management.
url http://hdl.handle.net/1721.1/90248
work_keys_str_mv AT rabassaalbertoiiialbertoscar economicperformanceofmodularizedhotaislecontaineddatacenterpodsutilizinghorizontalairflowcooling