Comparison of median frequency between traditional and functional sensor placements during activity monitoring

Long-term monitoring is of great clinical relevance. Accelerometers are often used to provide information about activities of daily living. The median frequency (f[subscript m]) of acceleration has recently been suggested as a powerful parameter for activity recognition. However, compliance issues a...

Full description

Bibliographic Details
Main Authors: Graham, Selina, Howard, Newton, McGregor, Alison, Bergmann, Jeroen H. M.
Other Authors: Massachusetts Institute of Technology. Media Laboratory
Format: Article
Language:en_US
Published: Elsevier 2014
Online Access:http://hdl.handle.net/1721.1/90628
https://orcid.org/0000-0002-8503-3973
_version_ 1811090975545622528
author Graham, Selina
Howard, Newton
McGregor, Alison
Bergmann, Jeroen H. M.
author2 Massachusetts Institute of Technology. Media Laboratory
author_facet Massachusetts Institute of Technology. Media Laboratory
Graham, Selina
Howard, Newton
McGregor, Alison
Bergmann, Jeroen H. M.
author_sort Graham, Selina
collection MIT
description Long-term monitoring is of great clinical relevance. Accelerometers are often used to provide information about activities of daily living. The median frequency (f[subscript m]) of acceleration has recently been suggested as a powerful parameter for activity recognition. However, compliance issues arise when people need to integrate activity recognition sensors into their daily lives. More functional placements should provide higher levels of conformity, but may also affect the quality and generalizability of the signals. How f[subscript m] changes as a result of a more functional sensor placement remains unclear. This study investigates the agreement in f[subscript m] for a sensor placed on the back with one in the pocket across a range of daily activities. The translational and gravitational accelerations are also computed to determine if the accelerometer should be fused with additional sensors to improve agreement. Twelve subjects were tested over four tasks and only the “vertical” x-axis showed a moderate agreement (Intraclass Correlation Coefficient of 0.54) after correction for outliers. Generalizability across traditional and functional sensor locations might therefore be limited. Differentiation of the signal into a translational and gravitational component decreased the level of agreement further, suggesting that combined information streams are more robust to changing locations then singular data streams. Integrating multiple sensor modalities to obtain specific components is unlikely to improve agreement across sensor locations. More research is needed to explore measurement signals of more user friendly sensor configurations that will lead to a greater clinical acceptance of body worn sensor systems.
first_indexed 2024-09-23T14:55:08Z
format Article
id mit-1721.1/90628
institution Massachusetts Institute of Technology
language en_US
last_indexed 2024-09-23T14:55:08Z
publishDate 2014
publisher Elsevier
record_format dspace
spelling mit-1721.1/906282022-09-29T11:23:26Z Comparison of median frequency between traditional and functional sensor placements during activity monitoring Graham, Selina Howard, Newton McGregor, Alison Bergmann, Jeroen H. M. Massachusetts Institute of Technology. Media Laboratory Massachusetts Institute of Technology. Synthetic Intelligence Laboratory Bergmann, Jeroen H. M. Howard, Newton Long-term monitoring is of great clinical relevance. Accelerometers are often used to provide information about activities of daily living. The median frequency (f[subscript m]) of acceleration has recently been suggested as a powerful parameter for activity recognition. However, compliance issues arise when people need to integrate activity recognition sensors into their daily lives. More functional placements should provide higher levels of conformity, but may also affect the quality and generalizability of the signals. How f[subscript m] changes as a result of a more functional sensor placement remains unclear. This study investigates the agreement in f[subscript m] for a sensor placed on the back with one in the pocket across a range of daily activities. The translational and gravitational accelerations are also computed to determine if the accelerometer should be fused with additional sensors to improve agreement. Twelve subjects were tested over four tasks and only the “vertical” x-axis showed a moderate agreement (Intraclass Correlation Coefficient of 0.54) after correction for outliers. Generalizability across traditional and functional sensor locations might therefore be limited. Differentiation of the signal into a translational and gravitational component decreased the level of agreement further, suggesting that combined information streams are more robust to changing locations then singular data streams. Integrating multiple sensor modalities to obtain specific components is unlikely to improve agreement across sensor locations. More research is needed to explore measurement signals of more user friendly sensor configurations that will lead to a greater clinical acceptance of body worn sensor systems. 2014-10-08T14:51:35Z 2014-10-08T14:51:35Z 2013-03 2013-03 Article http://purl.org/eprint/type/JournalArticle 02632241 http://hdl.handle.net/1721.1/90628 Bergmann, Jeroen H.M., Selina Graham, Newton Howard, and Alison McGregor. “Comparison of Median Frequency Between Traditional and Functional Sensor Placements During Activity Monitoring.” Measurement 46, no. 7 (August 2013): 2193–2200. © 2013 Elsevier Ltd. https://orcid.org/0000-0002-8503-3973 en_US http://dx.doi.org/10.1016/j.measurement.2013.03.004 Measurement Creative Commons Attribution http://creativecommons.org/licenses/by/3.0/ application/pdf Elsevier Elsevier
spellingShingle Graham, Selina
Howard, Newton
McGregor, Alison
Bergmann, Jeroen H. M.
Comparison of median frequency between traditional and functional sensor placements during activity monitoring
title Comparison of median frequency between traditional and functional sensor placements during activity monitoring
title_full Comparison of median frequency between traditional and functional sensor placements during activity monitoring
title_fullStr Comparison of median frequency between traditional and functional sensor placements during activity monitoring
title_full_unstemmed Comparison of median frequency between traditional and functional sensor placements during activity monitoring
title_short Comparison of median frequency between traditional and functional sensor placements during activity monitoring
title_sort comparison of median frequency between traditional and functional sensor placements during activity monitoring
url http://hdl.handle.net/1721.1/90628
https://orcid.org/0000-0002-8503-3973
work_keys_str_mv AT grahamselina comparisonofmedianfrequencybetweentraditionalandfunctionalsensorplacementsduringactivitymonitoring
AT howardnewton comparisonofmedianfrequencybetweentraditionalandfunctionalsensorplacementsduringactivitymonitoring
AT mcgregoralison comparisonofmedianfrequencybetweentraditionalandfunctionalsensorplacementsduringactivitymonitoring
AT bergmannjeroenhm comparisonofmedianfrequencybetweentraditionalandfunctionalsensorplacementsduringactivitymonitoring