Wavelet based fault analysis in HVDC system
HVDC system has become practically mature over the years but it is still met with some protection issues which should be discussed, for example, the circuit breaker (CB) should be selective to not trip if the transient is temporary, such as overcurrent due to load change. This paper addresses the pr...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Conference Paper |
Language: | English |
Published: |
2015
|
Subjects: | |
Online Access: | https://hdl.handle.net/10356/101927 http://hdl.handle.net/10220/25180 http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=7048852&refinements%3D4246517214%26punumber%3D7036020%26filter%3DAND%28p_IS_Number%3A7048466%29 |
_version_ | 1826114937421824000 |
---|---|
author | Yeap, Yew Ming Ukil, Abishek |
author2 | School of Electrical and Electronic Engineering |
author_facet | School of Electrical and Electronic Engineering Yeap, Yew Ming Ukil, Abishek |
author_sort | Yeap, Yew Ming |
collection | NTU |
description | HVDC system has become practically mature over the years but it is still met with some protection issues which should be discussed, for example, the circuit breaker (CB) should be selective to not trip if the transient is temporary, such as overcurrent due to load change. This paper addresses the problem with identifying the type of faults in a HVDC system using wavelet transform (WT). The wavelet transform is proven to be able to capture the distinctive feature of the fault pattern, specifically fault current rising time and oscillation pattern, which are helpful to form a basis for the tripping decision. Three phase-to-ground fault and DC fault are of concern in this paper as their effects are the most detrimental to the system. The point- to-point HVDC system is simulated using PSCAD, and the simulation result is subsequently processed in MATLAB to perform the wavelet transform. |
first_indexed | 2024-10-01T03:47:21Z |
format | Conference Paper |
id | ntu-10356/101927 |
institution | Nanyang Technological University |
language | English |
last_indexed | 2024-10-01T03:47:21Z |
publishDate | 2015 |
record_format | dspace |
spelling | ntu-10356/1019272019-12-06T20:46:44Z Wavelet based fault analysis in HVDC system Yeap, Yew Ming Ukil, Abishek School of Electrical and Electronic Engineering Annual Conference of the IEEE Industrial Electronics Society (40th : 2014 : Dallas, USA) DRNTU::Engineering::Electrical and electronic engineering::Antennas, wave guides, microwaves, radar, radio HVDC system has become practically mature over the years but it is still met with some protection issues which should be discussed, for example, the circuit breaker (CB) should be selective to not trip if the transient is temporary, such as overcurrent due to load change. This paper addresses the problem with identifying the type of faults in a HVDC system using wavelet transform (WT). The wavelet transform is proven to be able to capture the distinctive feature of the fault pattern, specifically fault current rising time and oscillation pattern, which are helpful to form a basis for the tripping decision. Three phase-to-ground fault and DC fault are of concern in this paper as their effects are the most detrimental to the system. The point- to-point HVDC system is simulated using PSCAD, and the simulation result is subsequently processed in MATLAB to perform the wavelet transform. Accepted version 2015-03-04T09:27:13Z 2019-12-06T20:46:44Z 2015-03-04T09:27:13Z 2019-12-06T20:46:44Z 2014 2014 Conference Paper Yeap, Y. M., & Ukil, A. (2014). Wavelet based fault analysis in HVDC system. Annual Conference of the IEEE Industrial Electronics Society( pp.2472-2478). Dallas: IEEE. https://hdl.handle.net/10356/101927 http://hdl.handle.net/10220/25180 http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=7048852&refinements%3D4246517214%26punumber%3D7036020%26filter%3DAND%28p_IS_Number%3A7048466%29 en © 2014 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works. The published version is available at: [http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=7048852&refinements%3D4246517214%26punumber%3D7036020%26filter%3DAND%28p_IS_Number%3A7048466%29]. 7 p. application/pdf |
spellingShingle | DRNTU::Engineering::Electrical and electronic engineering::Antennas, wave guides, microwaves, radar, radio Yeap, Yew Ming Ukil, Abishek Wavelet based fault analysis in HVDC system |
title | Wavelet based fault analysis in HVDC system |
title_full | Wavelet based fault analysis in HVDC system |
title_fullStr | Wavelet based fault analysis in HVDC system |
title_full_unstemmed | Wavelet based fault analysis in HVDC system |
title_short | Wavelet based fault analysis in HVDC system |
title_sort | wavelet based fault analysis in hvdc system |
topic | DRNTU::Engineering::Electrical and electronic engineering::Antennas, wave guides, microwaves, radar, radio |
url | https://hdl.handle.net/10356/101927 http://hdl.handle.net/10220/25180 http://ieeexplore.ieee.org/xpl/articleDetails.jsp?arnumber=7048852&refinements%3D4246517214%26punumber%3D7036020%26filter%3DAND%28p_IS_Number%3A7048466%29 |
work_keys_str_mv | AT yeapyewming waveletbasedfaultanalysisinhvdcsystem AT ukilabishek waveletbasedfaultanalysisinhvdcsystem |