A microfluidic liquid phase nucleic acid purification chip to selectively isolate DNA or RNA from low copy/single bacterial cells in minute sample volume followed by direct on-chip quantitative PCR assay
Purification of nucleic acids from a low quantity of bacterial cells in minute volume is important in many clinical and biological applications. We developed a novel microfluidic liquid phase nucleic acid purification chip to selectively isolate DNA or RNA from bacterial cells in the range of 5000 d...
Main Authors: | Zhang, Rui, Gong Haiqing, Thomas, Zeng, Xu Dong, Lou, Chao-Ping, Sze, Chun Chau |
---|---|
Other Authors: | School of Mechanical and Aerospace Engineering |
Format: | Journal Article |
Language: | English |
Published: |
2013
|
Subjects: | |
Online Access: | https://hdl.handle.net/10356/102378 http://hdl.handle.net/10220/16831 |
Similar Items
-
Experimental investigation on working of PCR chip
by: Ahluwalia Kunal
Published: (2014) -
Flow-through colorimetric assay for detection of nucleic acids in plasma
by: Ammanath, Gopal, et al.
Published: (2020) -
Inter-laboratory comparison of eleven quantitative or digital PCR assays for detection of proviral bovine leukemia virus in blood samples
by: Pluta, Aneta, et al.
Published: (2024) -
One more minute
by: Liew, Ming Jia
Published: (2015) -
3-D mesh-based optical network-on-chip for multiprocessor system-on-chip
by: Ye, Yaoyao, et al.
Published: (2013)