3D numerical simulation of a Coulter counter array with analysis of electrokinetic forces

Coulter counters have played an important role in biological cell assays since their introduction decades ago. Several types of high throughput micro-Coulter counters based on lab-on-chip devices have been commercialized recently. In this paper, we propose a highly integrated micro-Coulter counter a...

Full description

Bibliographic Details
Main Authors: Pui, Tze Sian, Guo, Jinhong, Rahman, Abdur Rub Abdur, Kang, Yuejun
Other Authors: School of Chemical and Biomedical Engineering
Format: Journal Article
Language:English
Published: 2013
Online Access:https://hdl.handle.net/10356/105332
http://hdl.handle.net/10220/16577
http://dx.doi.org/10.1002/elps.201200418
_version_ 1824455732421984256
author Pui, Tze Sian
Guo, Jinhong
Rahman, Abdur Rub Abdur
Kang, Yuejun
author2 School of Chemical and Biomedical Engineering
author_facet School of Chemical and Biomedical Engineering
Pui, Tze Sian
Guo, Jinhong
Rahman, Abdur Rub Abdur
Kang, Yuejun
author_sort Pui, Tze Sian
collection NTU
description Coulter counters have played an important role in biological cell assays since their introduction decades ago. Several types of high throughput micro-Coulter counters based on lab-on-chip devices have been commercialized recently. In this paper, we propose a highly integrated micro-Coulter counter array working under low DC voltage. The real-time electrical current change, including the pulse amplitude and width, of the micro-Coulter counter with novel structure is systematically investigated numerically. The major types of forces exerted on the particle in the micro-Coulter counter, including hydrodynamic force and electrokinetic force are quantitatively analyzed. The simulation in this study shows the pulse profile, such as width and amplitude, is affected by both particle size and the flow condition. The special cases of multiple particle aggregation and cross-talk between neighboring channels are also considered for their effects on the electric current pulses. This simulation provides critical insight and guidance for developing next new generations of micro-Coulter counter.
first_indexed 2025-02-19T03:42:53Z
format Journal Article
id ntu-10356/105332
institution Nanyang Technological University
language English
last_indexed 2025-02-19T03:42:53Z
publishDate 2013
record_format dspace
spelling ntu-10356/1053322019-12-06T21:49:17Z 3D numerical simulation of a Coulter counter array with analysis of electrokinetic forces Pui, Tze Sian Guo, Jinhong Rahman, Abdur Rub Abdur Kang, Yuejun School of Chemical and Biomedical Engineering Coulter counters have played an important role in biological cell assays since their introduction decades ago. Several types of high throughput micro-Coulter counters based on lab-on-chip devices have been commercialized recently. In this paper, we propose a highly integrated micro-Coulter counter array working under low DC voltage. The real-time electrical current change, including the pulse amplitude and width, of the micro-Coulter counter with novel structure is systematically investigated numerically. The major types of forces exerted on the particle in the micro-Coulter counter, including hydrodynamic force and electrokinetic force are quantitatively analyzed. The simulation in this study shows the pulse profile, such as width and amplitude, is affected by both particle size and the flow condition. The special cases of multiple particle aggregation and cross-talk between neighboring channels are also considered for their effects on the electric current pulses. This simulation provides critical insight and guidance for developing next new generations of micro-Coulter counter. 2013-10-18T02:32:28Z 2019-12-06T21:49:17Z 2013-10-18T02:32:28Z 2019-12-06T21:49:17Z 2012 2012 Journal Article Guo, J., Pui, T. S., Rahman, A. R. A.,& Kang, Y. (2013). 3D numerical simulation of a Coulter counter array with analysis of electrokinetic forces. ELECTROPHORESIS, 34(3), 417-424. 0173-0835 https://hdl.handle.net/10356/105332 http://hdl.handle.net/10220/16577 http://dx.doi.org/10.1002/elps.201200418 en ELECTROPHORESIS
spellingShingle Pui, Tze Sian
Guo, Jinhong
Rahman, Abdur Rub Abdur
Kang, Yuejun
3D numerical simulation of a Coulter counter array with analysis of electrokinetic forces
title 3D numerical simulation of a Coulter counter array with analysis of electrokinetic forces
title_full 3D numerical simulation of a Coulter counter array with analysis of electrokinetic forces
title_fullStr 3D numerical simulation of a Coulter counter array with analysis of electrokinetic forces
title_full_unstemmed 3D numerical simulation of a Coulter counter array with analysis of electrokinetic forces
title_short 3D numerical simulation of a Coulter counter array with analysis of electrokinetic forces
title_sort 3d numerical simulation of a coulter counter array with analysis of electrokinetic forces
url https://hdl.handle.net/10356/105332
http://hdl.handle.net/10220/16577
http://dx.doi.org/10.1002/elps.201200418
work_keys_str_mv AT puitzesian 3dnumericalsimulationofacoultercounterarraywithanalysisofelectrokineticforces
AT guojinhong 3dnumericalsimulationofacoultercounterarraywithanalysisofelectrokineticforces
AT rahmanabdurrubabdur 3dnumericalsimulationofacoultercounterarraywithanalysisofelectrokineticforces
AT kangyuejun 3dnumericalsimulationofacoultercounterarraywithanalysisofelectrokineticforces