Group average difference : A termination criterion for active contour

This paper presents a termination criterion for active contour that does not involve alteration of the energy functional. The criterion is based on the area difference of the contour during evolution. In this criterion, the evolution of the contour terminates when the area difference fluctuates arou...

Full description

Bibliographic Details
Main Authors: Chuah, Tong Kuan, Lim, Jun Hong, Poh, Chueh Loo
Other Authors: School of Chemical and Biomedical Engineering
Format: Journal Article
Language:English
Published: 2013
Subjects:
Online Access:https://hdl.handle.net/10356/107361
http://hdl.handle.net/10220/18021
_version_ 1826121896166424576
author Chuah, Tong Kuan
Lim, Jun Hong
Poh, Chueh Loo
author2 School of Chemical and Biomedical Engineering
author_facet School of Chemical and Biomedical Engineering
Chuah, Tong Kuan
Lim, Jun Hong
Poh, Chueh Loo
author_sort Chuah, Tong Kuan
collection NTU
description This paper presents a termination criterion for active contour that does not involve alteration of the energy functional. The criterion is based on the area difference of the contour during evolution. In this criterion, the evolution of the contour terminates when the area difference fluctuates around a constant. The termination criterion is tested using parametric gradient vector flow active contour with contour resampling and normal force selection. The usefulness of the criterion is shown through its trend, speed, accuracy, shape insensitivity, and insensitivity to contour resampling. The metric used in the proposed criterion demonstrated a steadily decreasing trend. For automatic implementation in which different shapes need to be segmented, the proposed criterion demonstrated almost 50% and 60% total time reduction while achieving similar accuracy as compared with the pixel movement-based method in the segmentation of synthetic and real medical images, respectively. Our results also show that the proposed termination criterion is insensitive to shape variation and contour resampling. The criterion also possesses potential to be used for other kinds of snakes.
first_indexed 2024-10-01T05:39:39Z
format Journal Article
id ntu-10356/107361
institution Nanyang Technological University
language English
last_indexed 2024-10-01T05:39:39Z
publishDate 2013
record_format dspace
spelling ntu-10356/1073612022-02-16T16:28:11Z Group average difference : A termination criterion for active contour Chuah, Tong Kuan Lim, Jun Hong Poh, Chueh Loo School of Chemical and Biomedical Engineering DRNTU::Engineering::Chemical engineering This paper presents a termination criterion for active contour that does not involve alteration of the energy functional. The criterion is based on the area difference of the contour during evolution. In this criterion, the evolution of the contour terminates when the area difference fluctuates around a constant. The termination criterion is tested using parametric gradient vector flow active contour with contour resampling and normal force selection. The usefulness of the criterion is shown through its trend, speed, accuracy, shape insensitivity, and insensitivity to contour resampling. The metric used in the proposed criterion demonstrated a steadily decreasing trend. For automatic implementation in which different shapes need to be segmented, the proposed criterion demonstrated almost 50% and 60% total time reduction while achieving similar accuracy as compared with the pixel movement-based method in the segmentation of synthetic and real medical images, respectively. Our results also show that the proposed termination criterion is insensitive to shape variation and contour resampling. The criterion also possesses potential to be used for other kinds of snakes. 2013-12-04T04:34:44Z 2019-12-06T22:29:19Z 2013-12-04T04:34:44Z 2019-12-06T22:29:19Z 2012 2012 Journal Article Chuah, T. K., Lim, J. H., & Poh, C. L. (2012). Group average difference : A termination criterion for active contour. Journal of digital imaging, 25(2), 279-293. https://hdl.handle.net/10356/107361 http://hdl.handle.net/10220/18021 10.1007/s10278-011-9405-y 21773868 en Journal of digital imaging
spellingShingle DRNTU::Engineering::Chemical engineering
Chuah, Tong Kuan
Lim, Jun Hong
Poh, Chueh Loo
Group average difference : A termination criterion for active contour
title Group average difference : A termination criterion for active contour
title_full Group average difference : A termination criterion for active contour
title_fullStr Group average difference : A termination criterion for active contour
title_full_unstemmed Group average difference : A termination criterion for active contour
title_short Group average difference : A termination criterion for active contour
title_sort group average difference a termination criterion for active contour
topic DRNTU::Engineering::Chemical engineering
url https://hdl.handle.net/10356/107361
http://hdl.handle.net/10220/18021
work_keys_str_mv AT chuahtongkuan groupaveragedifferenceaterminationcriterionforactivecontour
AT limjunhong groupaveragedifferenceaterminationcriterionforactivecontour
AT pohchuehloo groupaveragedifferenceaterminationcriterionforactivecontour