Magnetic field assisted preconcentration of biomolecules for lateral flow assaying

Lateral flow assays (LFA) have been extensively explored for rapid and cost effective point-of-care diagnostics. Typically, LFA responses are influenced by the complexity of sample matrices containing analogues or molecules that may potentially yield non-specific responses, for instance, when assayi...

Full description

Bibliographic Details
Main Authors: Sharma, Antareep, Tok, Alfred Iing Yoong, Lee, Chleo, Ganapathy, Rajasege, Palaniappan, Alagappan, Liedberg, Bo
Other Authors: School of Materials Science and Engineering
Format: Journal Article
Language:English
Published: 2020
Subjects:
Online Access:https://hdl.handle.net/10356/143212
_version_ 1811682743166173184
author Sharma, Antareep
Tok, Alfred Iing Yoong
Lee, Chleo
Ganapathy, Rajasege
Palaniappan, Alagappan
Liedberg, Bo
author2 School of Materials Science and Engineering
author_facet School of Materials Science and Engineering
Sharma, Antareep
Tok, Alfred Iing Yoong
Lee, Chleo
Ganapathy, Rajasege
Palaniappan, Alagappan
Liedberg, Bo
author_sort Sharma, Antareep
collection NTU
description Lateral flow assays (LFA) have been extensively explored for rapid and cost effective point-of-care diagnostics. Typically, LFA responses are influenced by the complexity of sample matrices containing analogues or molecules that may potentially yield non-specific responses, for instance, when assaying for biomarkers in blood, serum and plasma. Therefore, isolation of analytes of interest from sample matrices would significantly improve the LFA responses. Herein, we report a magnetic field assisted preconcentration approach for extraction and assay of proteins in an LFA format. Cardiac marker, Troponin (cTnICT complex), is utilized as a model system for validation of the proposed approach. Magnetic fields of different strengths are evaluated for retaining cTnICT on an LFA membrane utilizing magnetic beads conjugated with anti-Troponin I (anti-TnI) antibodies. The sample matrix components subsequently flows through to the absorbent pad via a hydrophilic passivation layer that is protecting the capturing anti-Troponin C (anti-TnC) antibodies in the test zone. Isolated TnI-magnetic bead complexes are then released to flow downstream along the LFA strip to the test zone upon removal of magnetic field and the passivation layer. The capture of cTnICT magnetic bead complexes at the test zone produces a characteristic brownish band, enabling concentration dependant visual detection of cTnICT. Experimental results indicate that the assay yields pM level sensitivity within 15 min using very low sample volumes (<100 μL), and with possibilities for signal enhancement. The reported assay offers a promising avenue for sensitive detection of target analytes in complex matrices at clinically relevant concentration levels without requiring tedious sample pre-treatment protocols.
first_indexed 2024-10-01T04:01:41Z
format Journal Article
id ntu-10356/143212
institution Nanyang Technological University
language English
last_indexed 2024-10-01T04:01:41Z
publishDate 2020
record_format dspace
spelling ntu-10356/1432122021-02-08T07:15:17Z Magnetic field assisted preconcentration of biomolecules for lateral flow assaying Sharma, Antareep Tok, Alfred Iing Yoong Lee, Chleo Ganapathy, Rajasege Palaniappan, Alagappan Liedberg, Bo School of Materials Science and Engineering Interdisciplinary Graduate School (IGS) Center for Biomimetic Sensor Science Engineering::Materials Lateral Flow Assay Protein Extraction Lateral flow assays (LFA) have been extensively explored for rapid and cost effective point-of-care diagnostics. Typically, LFA responses are influenced by the complexity of sample matrices containing analogues or molecules that may potentially yield non-specific responses, for instance, when assaying for biomarkers in blood, serum and plasma. Therefore, isolation of analytes of interest from sample matrices would significantly improve the LFA responses. Herein, we report a magnetic field assisted preconcentration approach for extraction and assay of proteins in an LFA format. Cardiac marker, Troponin (cTnICT complex), is utilized as a model system for validation of the proposed approach. Magnetic fields of different strengths are evaluated for retaining cTnICT on an LFA membrane utilizing magnetic beads conjugated with anti-Troponin I (anti-TnI) antibodies. The sample matrix components subsequently flows through to the absorbent pad via a hydrophilic passivation layer that is protecting the capturing anti-Troponin C (anti-TnC) antibodies in the test zone. Isolated TnI-magnetic bead complexes are then released to flow downstream along the LFA strip to the test zone upon removal of magnetic field and the passivation layer. The capture of cTnICT magnetic bead complexes at the test zone produces a characteristic brownish band, enabling concentration dependant visual detection of cTnICT. Experimental results indicate that the assay yields pM level sensitivity within 15 min using very low sample volumes (<100 μL), and with possibilities for signal enhancement. The reported assay offers a promising avenue for sensitive detection of target analytes in complex matrices at clinically relevant concentration levels without requiring tedious sample pre-treatment protocols. Accepted version 2020-08-12T09:22:25Z 2020-08-12T09:22:25Z 2019 Journal Article Sharma, A., Tok, A. l. Y., Lee, C., Ganapathy, R., Palaniappan, A., & Liedberg, B. (2019). Magnetic field assisted preconcentration of biomolecule s for lateral flow assaying. Sensors and Actuators B: Chemical, 285, 431-437. doi:10.1016/j.snb.2019.01.073 0925-4005 https://hdl.handle.net/10356/143212 10.1016/j.snb.2019.01.073 2-s2.0-85060292936 285 431 437 en Sensors and Actuators B: Chemical © 2019 Elsevier B.V. All rights reserved. This paper was published in Sensors and Actuators B: Chemical and is made available with permission of Elsevier B.V. application/pdf
spellingShingle Engineering::Materials
Lateral Flow Assay
Protein Extraction
Sharma, Antareep
Tok, Alfred Iing Yoong
Lee, Chleo
Ganapathy, Rajasege
Palaniappan, Alagappan
Liedberg, Bo
Magnetic field assisted preconcentration of biomolecules for lateral flow assaying
title Magnetic field assisted preconcentration of biomolecules for lateral flow assaying
title_full Magnetic field assisted preconcentration of biomolecules for lateral flow assaying
title_fullStr Magnetic field assisted preconcentration of biomolecules for lateral flow assaying
title_full_unstemmed Magnetic field assisted preconcentration of biomolecules for lateral flow assaying
title_short Magnetic field assisted preconcentration of biomolecules for lateral flow assaying
title_sort magnetic field assisted preconcentration of biomolecules for lateral flow assaying
topic Engineering::Materials
Lateral Flow Assay
Protein Extraction
url https://hdl.handle.net/10356/143212
work_keys_str_mv AT sharmaantareep magneticfieldassistedpreconcentrationofbiomoleculesforlateralflowassaying
AT tokalfrediingyoong magneticfieldassistedpreconcentrationofbiomoleculesforlateralflowassaying
AT leechleo magneticfieldassistedpreconcentrationofbiomoleculesforlateralflowassaying
AT ganapathyrajasege magneticfieldassistedpreconcentrationofbiomoleculesforlateralflowassaying
AT palaniappanalagappan magneticfieldassistedpreconcentrationofbiomoleculesforlateralflowassaying
AT liedbergbo magneticfieldassistedpreconcentrationofbiomoleculesforlateralflowassaying