Ultrahigh-resolution optical coherence tomography provides an axial resolution of 1-2 μm for resolving cellular structures of biological tissues critical for the diagnosis of diseases. However, it requires a relatively large spectral bandwidth which is not supported by the key components of the imag...

全面介紹

書目詳細資料
Main Authors: Liu, Lishuang, Xie, Jun, Liu, Linbo, Chen, Si
其他作者: School of Electrical and Electronic Engineering
格式: Journal Article
語言:English
出版: 2021
主題:
在線閱讀:https://hdl.handle.net/10356/147605
_version_ 1826129425512529920
author Liu, Lishuang
Xie, Jun
Liu, Linbo
Chen, Si
author2 School of Electrical and Electronic Engineering
author_facet School of Electrical and Electronic Engineering
Liu, Lishuang
Xie, Jun
Liu, Linbo
Chen, Si
author_sort Liu, Lishuang
collection NTU
description Ultrahigh-resolution optical coherence tomography provides an axial resolution of 1-2 μm for resolving cellular structures of biological tissues critical for the diagnosis of diseases. However, it requires a relatively large spectral bandwidth which is not supported by the key components of the imaging system. We propose a novel spectral-domain OCT design, termed interferometer-in-spectrometer, which is able to compensate the bandwidth limitations of the grating and the line scan sensor by spectral shaping without compromising the signal intensity and adding the system cost. The advantage of axial resolution and ranging depth over the standard design is experimentally validated using the standard testing method and fresh swine cornea ex vivo. Moreover, opportunities that opened up by this new scheme for improving the performances of spectral-domain OCT are also discussed.
first_indexed 2024-10-01T07:40:24Z
format Journal Article
id ntu-10356/147605
institution Nanyang Technological University
language English
last_indexed 2024-10-01T07:40:24Z
publishDate 2021
record_format dspace
spelling ntu-10356/1476052021-04-13T08:47:31Z Interferometer-in-spectrometer for high-resolution optical coherence tomography Liu, Lishuang Xie, Jun Liu, Linbo Chen, Si School of Electrical and Electronic Engineering School of Chemical and Biomedical Engineering Engineering::Electrical and electronic engineering Optical Coherence Tomography Spectral Bandwidth Ultrahigh-resolution optical coherence tomography provides an axial resolution of 1-2 μm for resolving cellular structures of biological tissues critical for the diagnosis of diseases. However, it requires a relatively large spectral bandwidth which is not supported by the key components of the imaging system. We propose a novel spectral-domain OCT design, termed interferometer-in-spectrometer, which is able to compensate the bandwidth limitations of the grating and the line scan sensor by spectral shaping without compromising the signal intensity and adding the system cost. The advantage of axial resolution and ranging depth over the standard design is experimentally validated using the standard testing method and fresh swine cornea ex vivo. Moreover, opportunities that opened up by this new scheme for improving the performances of spectral-domain OCT are also discussed. Published version 2021-04-13T08:47:31Z 2021-04-13T08:47:31Z 2020 Journal Article Liu, L., Xie, J., Liu, L. & Chen, S. (2020). Interferometer-in-spectrometer for high-resolution optical coherence tomography. Journal of Sensors, 2020. https://dx.doi.org/10.1155/2020/2530257 1687-725X 0000-0002-7465-0861 0000-0002-4683-9130 https://hdl.handle.net/10356/147605 10.1155/2020/2530257 2-s2.0-85078022595 2020 en Journal of Sensors © 2020 The Author(s). This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. application/pdf
spellingShingle Engineering::Electrical and electronic engineering
Optical Coherence Tomography
Spectral Bandwidth
Liu, Lishuang
Xie, Jun
Liu, Linbo
Chen, Si
Interferometer-in-spectrometer for high-resolution optical coherence tomography
title Interferometer-in-spectrometer for high-resolution optical coherence tomography
title_full Interferometer-in-spectrometer for high-resolution optical coherence tomography
title_fullStr Interferometer-in-spectrometer for high-resolution optical coherence tomography
title_full_unstemmed Interferometer-in-spectrometer for high-resolution optical coherence tomography
title_short Interferometer-in-spectrometer for high-resolution optical coherence tomography
title_sort interferometer in spectrometer for high resolution optical coherence tomography
topic Engineering::Electrical and electronic engineering
Optical Coherence Tomography
Spectral Bandwidth
url https://hdl.handle.net/10356/147605
work_keys_str_mv AT liulishuang interferometerinspectrometerforhighresolutionopticalcoherencetomography
AT xiejun interferometerinspectrometerforhighresolutionopticalcoherencetomography
AT liulinbo interferometerinspectrometerforhighresolutionopticalcoherencetomography
AT chensi interferometerinspectrometerforhighresolutionopticalcoherencetomography