Microgrid system health management

This project focuses on the development of a supervised machine learning model for fault detection and prognosis in a Permanent Magnet Synchronous Generator (PMSG) system. With a prolonged use of electrical machines, wear and tear in some of the components will occur, which will affect the performan...

Full description

Bibliographic Details
Main Author: Yeo, Wee Tat
Other Authors: Soong Boon Hee
Format: Final Year Project (FYP)
Language:English
Published: Nanyang Technological University 2021
Subjects:
Online Access:https://hdl.handle.net/10356/150011
_version_ 1826118761001779200
author Yeo, Wee Tat
author2 Soong Boon Hee
author_facet Soong Boon Hee
Yeo, Wee Tat
author_sort Yeo, Wee Tat
collection NTU
description This project focuses on the development of a supervised machine learning model for fault detection and prognosis in a Permanent Magnet Synchronous Generator (PMSG) system. With a prolonged use of electrical machines, wear and tear in some of the components will occur, which will affect the performance of the PMSG. Early detection of faults is essential as corrective maintenance can be performed before the faulty component damages the equipment further. Following the supervised machine learning workflow, a model was selected and developed for a PMSG system to detect various health types from input data. Healthy, winding fault and bearing fault simulations were experimentally introduced into the PMSG and the data was collected for analysis and processing for model training. Features were generated from the training data with the help of MATLAB Diagnostic Feature Designer and ranked with one-way Analysis of Variance (ANOVA) in order of importance. The selected features were then exported to the Classification Learner application to train and evaluate the supervised machine learning models. In the project, a cubic Support Vector Machine (SVM) model with an accuracy of 90% was developed and used on the test data for prediction. Model testing resulted in an accuracy of 90%, which was within the range of the accuracy obtained during model training. Selection of several parameters also enabled an interpretation of the scatter plot. Separately, analysis was performed on the phase currents and vibration to find insights from the data.
first_indexed 2024-10-01T04:49:07Z
format Final Year Project (FYP)
id ntu-10356/150011
institution Nanyang Technological University
language English
last_indexed 2024-10-01T04:49:07Z
publishDate 2021
publisher Nanyang Technological University
record_format dspace
spelling ntu-10356/1500112023-07-07T18:32:58Z Microgrid system health management Yeo, Wee Tat Soong Boon Hee School of Electrical and Electronic Engineering Rolls-Royce@NTU Corporate Lab EBHSOONG@ntu.edu.sg Engineering::Electrical and electronic engineering This project focuses on the development of a supervised machine learning model for fault detection and prognosis in a Permanent Magnet Synchronous Generator (PMSG) system. With a prolonged use of electrical machines, wear and tear in some of the components will occur, which will affect the performance of the PMSG. Early detection of faults is essential as corrective maintenance can be performed before the faulty component damages the equipment further. Following the supervised machine learning workflow, a model was selected and developed for a PMSG system to detect various health types from input data. Healthy, winding fault and bearing fault simulations were experimentally introduced into the PMSG and the data was collected for analysis and processing for model training. Features were generated from the training data with the help of MATLAB Diagnostic Feature Designer and ranked with one-way Analysis of Variance (ANOVA) in order of importance. The selected features were then exported to the Classification Learner application to train and evaluate the supervised machine learning models. In the project, a cubic Support Vector Machine (SVM) model with an accuracy of 90% was developed and used on the test data for prediction. Model testing resulted in an accuracy of 90%, which was within the range of the accuracy obtained during model training. Selection of several parameters also enabled an interpretation of the scatter plot. Separately, analysis was performed on the phase currents and vibration to find insights from the data. Bachelor of Engineering (Electrical and Electronic Engineering) 2021-06-10T02:58:11Z 2021-06-10T02:58:11Z 2021 Final Year Project (FYP) Yeo, W. T. (2021). Microgrid system health management. Final Year Project (FYP), Nanyang Technological University, Singapore. https://hdl.handle.net/10356/150011 https://hdl.handle.net/10356/150011 en B3230-201 application/pdf Nanyang Technological University
spellingShingle Engineering::Electrical and electronic engineering
Yeo, Wee Tat
Microgrid system health management
title Microgrid system health management
title_full Microgrid system health management
title_fullStr Microgrid system health management
title_full_unstemmed Microgrid system health management
title_short Microgrid system health management
title_sort microgrid system health management
topic Engineering::Electrical and electronic engineering
url https://hdl.handle.net/10356/150011
work_keys_str_mv AT yeoweetat microgridsystemhealthmanagement