Fibre Bragg Grating (FBG)-based force and pose sensing for endoscopic robotic systems

Haptic feedback and motion tracking are still absent in the Robotic Minimally Invasive Surgery (RMIS). The non-transparency between the master-slave system affects the surgeon's situation awareness and safety assessment during an operation. Therefore, there is a demand for developing mini...

Full description

Bibliographic Details
Main Author: Lai, Wenjie
Other Authors: Phee Soo Jay, Louis
Format: Thesis-Doctor of Philosophy
Language:English
Published: Nanyang Technological University 2021
Subjects:
Online Access:https://hdl.handle.net/10356/150542
_version_ 1811682559226019840
author Lai, Wenjie
author2 Phee Soo Jay, Louis
author_facet Phee Soo Jay, Louis
Lai, Wenjie
author_sort Lai, Wenjie
collection NTU
description Haptic feedback and motion tracking are still absent in the Robotic Minimally Invasive Surgery (RMIS). The non-transparency between the master-slave system affects the surgeon's situation awareness and safety assessment during an operation. Therefore, there is a demand for developing miniature sensors to detect the tool-tissue interaction in surgical robotics. Due to tighter space constraints in the flexible endoscopic robot, it becomes much more challenging to advance sensors in such a robotic system. The research aims to develop novel and practical solutions to realize force sensing and pose sensing for flexible endoscopic surgical robots. A single-axis force sensor (two versions), an integrated sensor-model approach, a three -axial force sensor have been proposed to capture the distal force in an endoscopic surgical robot driven by Tendon-Sheath Mechanisms (TSMs). The single-axis force sensor was integrated with the actuation mechanism, measuring the distal tension force in real-time, with a sensitivity of 34.14 pm/N. The integrated sensor-model approach has been validated in a 5-DoF (Degree of Freedom) grasper in both in-vitro tests and an animal study (in a live porcine). This approach saves cost and space while maintaining the robustness of the sensing system. Another three-axial force sensor has been further explored to reflect the tool-tissue interaction forces, with a lateral force sensitivity up to 1757.438 pm/N. Validation tests have been conducted to show its measurement capability of pulling force (0 N to 6 N), steering force (-3.5 N to 3 N), and lifting force (-4.5 N to 4.5 N). Besides, real-time forces have been displayed on the surgeon's hand through the haptic device, Omega7. In addition, a rotation angle sensor (RAS) has been developed to detect a pivot joint's rotation angle in the articulated surgical grasper, with a broad measurable range of angles [-47.8°, 39.1°] and a small bending radius down to 6.9 mm. Apart from flexible endoscopic robots, the single-axis force sensor and the integrated sensor-model approach can also be applied in TSM-driven or tendon-driven robotic fingers/hands, wearable devices, surgical catheters, and rehabilitation devices. The three-axial force sensor can also be shifted to a laparoscopic robot or a catheter, not limited to the flexible endoscopic surgical robot. The RAS can also be used in continuum robots or soft robots to detect the large bending deflection.
first_indexed 2024-10-01T03:58:46Z
format Thesis-Doctor of Philosophy
id ntu-10356/150542
institution Nanyang Technological University
language English
last_indexed 2024-10-01T03:58:46Z
publishDate 2021
publisher Nanyang Technological University
record_format dspace
spelling ntu-10356/1505422023-03-11T17:53:10Z Fibre Bragg Grating (FBG)-based force and pose sensing for endoscopic robotic systems Lai, Wenjie Phee Soo Jay, Louis Tjin Swee Chuan School of Mechanical and Aerospace Engineering Robotics Research Centre MSJPhee@ntu.edu.sg, ESCTJIN@ntu.edu.sg Engineering::Mechanical engineering::Surgical assistive technology Engineering::Mechanical engineering::Robots Haptic feedback and motion tracking are still absent in the Robotic Minimally Invasive Surgery (RMIS). The non-transparency between the master-slave system affects the surgeon's situation awareness and safety assessment during an operation. Therefore, there is a demand for developing miniature sensors to detect the tool-tissue interaction in surgical robotics. Due to tighter space constraints in the flexible endoscopic robot, it becomes much more challenging to advance sensors in such a robotic system. The research aims to develop novel and practical solutions to realize force sensing and pose sensing for flexible endoscopic surgical robots. A single-axis force sensor (two versions), an integrated sensor-model approach, a three -axial force sensor have been proposed to capture the distal force in an endoscopic surgical robot driven by Tendon-Sheath Mechanisms (TSMs). The single-axis force sensor was integrated with the actuation mechanism, measuring the distal tension force in real-time, with a sensitivity of 34.14 pm/N. The integrated sensor-model approach has been validated in a 5-DoF (Degree of Freedom) grasper in both in-vitro tests and an animal study (in a live porcine). This approach saves cost and space while maintaining the robustness of the sensing system. Another three-axial force sensor has been further explored to reflect the tool-tissue interaction forces, with a lateral force sensitivity up to 1757.438 pm/N. Validation tests have been conducted to show its measurement capability of pulling force (0 N to 6 N), steering force (-3.5 N to 3 N), and lifting force (-4.5 N to 4.5 N). Besides, real-time forces have been displayed on the surgeon's hand through the haptic device, Omega7. In addition, a rotation angle sensor (RAS) has been developed to detect a pivot joint's rotation angle in the articulated surgical grasper, with a broad measurable range of angles [-47.8°, 39.1°] and a small bending radius down to 6.9 mm. Apart from flexible endoscopic robots, the single-axis force sensor and the integrated sensor-model approach can also be applied in TSM-driven or tendon-driven robotic fingers/hands, wearable devices, surgical catheters, and rehabilitation devices. The three-axial force sensor can also be shifted to a laparoscopic robot or a catheter, not limited to the flexible endoscopic surgical robot. The RAS can also be used in continuum robots or soft robots to detect the large bending deflection. Doctor of Philosophy 2021-06-23T01:05:13Z 2021-06-23T01:05:13Z 2021 Thesis-Doctor of Philosophy Lai, W. (2021). Fibre Bragg Grating (FBG)-based force and pose sensing for endoscopic robotic systems. Doctoral thesis, Nanyang Technological University, Singapore. https://hdl.handle.net/10356/150542 https://hdl.handle.net/10356/150542 10.32657/10356/150542 en National Research Foundation (NRF) Singapore (NRFI2016-07) This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License (CC BY-NC 4.0). application/pdf Nanyang Technological University
spellingShingle Engineering::Mechanical engineering::Surgical assistive technology
Engineering::Mechanical engineering::Robots
Lai, Wenjie
Fibre Bragg Grating (FBG)-based force and pose sensing for endoscopic robotic systems
title Fibre Bragg Grating (FBG)-based force and pose sensing for endoscopic robotic systems
title_full Fibre Bragg Grating (FBG)-based force and pose sensing for endoscopic robotic systems
title_fullStr Fibre Bragg Grating (FBG)-based force and pose sensing for endoscopic robotic systems
title_full_unstemmed Fibre Bragg Grating (FBG)-based force and pose sensing for endoscopic robotic systems
title_short Fibre Bragg Grating (FBG)-based force and pose sensing for endoscopic robotic systems
title_sort fibre bragg grating fbg based force and pose sensing for endoscopic robotic systems
topic Engineering::Mechanical engineering::Surgical assistive technology
Engineering::Mechanical engineering::Robots
url https://hdl.handle.net/10356/150542
work_keys_str_mv AT laiwenjie fibrebragggratingfbgbasedforceandposesensingforendoscopicroboticsystems