Characterization of nano-layered solid-contact ion selective electrodes by simultaneous potentiometry and quartz crystal microbalance with dissipation

Nano-layered solid-contact potassium-selective electrodes (K⁺-ISEs) were explored as model ion-selective electrodes for their practical use in clinical analysis. The ultra-thin ISEs ought to be manufactured in a highly reproducible manner, potentially making them suitable for mass production. Thus,...

Fuld beskrivelse

Bibliografiske detaljer
Main Authors: Krikstolaityte, Vida, Ding, Ruiyu, Ruzgas, Tautgirdas, Björklund, Sebastian, Lisak, Grzegorz
Andre forfattere: School of Civil and Environmental Engineering
Format: Journal Article
Sprog:English
Udgivet: 2021
Fag:
Online adgang:https://hdl.handle.net/10356/152051
_version_ 1826110206845648896
author Krikstolaityte, Vida
Ding, Ruiyu
Ruzgas, Tautgirdas
Björklund, Sebastian
Lisak, Grzegorz
author2 School of Civil and Environmental Engineering
author_facet School of Civil and Environmental Engineering
Krikstolaityte, Vida
Ding, Ruiyu
Ruzgas, Tautgirdas
Björklund, Sebastian
Lisak, Grzegorz
author_sort Krikstolaityte, Vida
collection NTU
description Nano-layered solid-contact potassium-selective electrodes (K⁺-ISEs) were explored as model ion-selective electrodes for their practical use in clinical analysis. The ultra-thin ISEs ought to be manufactured in a highly reproducible manner, potentially making them suitable for mass production. Thus, their development is pivotal towards miniaturised sensors with simplified conditioning/calibration protocols for point-of-care diagnostics. To study nano-layered ISEs, the ultra-thin nature of ISEs for the first time enabled to combine potentiometry-quartz crystal microbalance with dissipation (QCM-D) to obtain value-added information on the ISE potentiometric response regarding their physical state such as mass/thickness/viscoelastic properties/structural homogeneity. Specifically, the studies were focused on real-time observations of the ISE potentiometric response in relation to changes of their physicochemical properties during the ISE preparation (conditioning) and operation (including biofouling conditions) to identify the occurring processes that may accordingly be critical for potential instability of the ISEs, impeding their practical application. The K⁺-ISEs were prepared on a QCM-D gold sensor by electrodepositing poly(3,4-ethylenedioxythiophene)-poly(styrene sulfonate) layer serving as an ion-to-electron transducer subsequently covered by a spin-coated poly(vinyl chloride) based K⁺-ion selective membrane (K⁺-ISM). The studies demonstrated that the performance of the nano-layered design of K⁺-ISEs is detrimentally affected by such processes as water layer formation accordingly causing the instability of the electrode potential. The changes in the ISE physical state such mass/viscoelastic properties associated with water layer formation and origin of the potential instability was already observed at the ISE conditioning stage. The potential instability of nano-layered ISEs limits their practical applicability, indicating the need of new solutions in designing ISEs, for instance, exploiting new water-resistant materials and modifying preparation protocols.
first_indexed 2024-10-01T02:30:37Z
format Journal Article
id ntu-10356/152051
institution Nanyang Technological University
language English
last_indexed 2024-10-01T02:30:37Z
publishDate 2021
record_format dspace
spelling ntu-10356/1520512021-08-02T07:46:43Z Characterization of nano-layered solid-contact ion selective electrodes by simultaneous potentiometry and quartz crystal microbalance with dissipation Krikstolaityte, Vida Ding, Ruiyu Ruzgas, Tautgirdas Björklund, Sebastian Lisak, Grzegorz School of Civil and Environmental Engineering Nanyang Environment and Water Research Institute Energy Research Institute @ NTU (ERI@N) Engineering::Environmental engineering Potentiometry Quartz Crystal Microbalance with Dissipation Nano-layered solid-contact potassium-selective electrodes (K⁺-ISEs) were explored as model ion-selective electrodes for their practical use in clinical analysis. The ultra-thin ISEs ought to be manufactured in a highly reproducible manner, potentially making them suitable for mass production. Thus, their development is pivotal towards miniaturised sensors with simplified conditioning/calibration protocols for point-of-care diagnostics. To study nano-layered ISEs, the ultra-thin nature of ISEs for the first time enabled to combine potentiometry-quartz crystal microbalance with dissipation (QCM-D) to obtain value-added information on the ISE potentiometric response regarding their physical state such as mass/thickness/viscoelastic properties/structural homogeneity. Specifically, the studies were focused on real-time observations of the ISE potentiometric response in relation to changes of their physicochemical properties during the ISE preparation (conditioning) and operation (including biofouling conditions) to identify the occurring processes that may accordingly be critical for potential instability of the ISEs, impeding their practical application. The K⁺-ISEs were prepared on a QCM-D gold sensor by electrodepositing poly(3,4-ethylenedioxythiophene)-poly(styrene sulfonate) layer serving as an ion-to-electron transducer subsequently covered by a spin-coated poly(vinyl chloride) based K⁺-ion selective membrane (K⁺-ISM). The studies demonstrated that the performance of the nano-layered design of K⁺-ISEs is detrimentally affected by such processes as water layer formation accordingly causing the instability of the electrode potential. The changes in the ISE physical state such mass/viscoelastic properties associated with water layer formation and origin of the potential instability was already observed at the ISE conditioning stage. The potential instability of nano-layered ISEs limits their practical applicability, indicating the need of new solutions in designing ISEs, for instance, exploiting new water-resistant materials and modifying preparation protocols. Economic Development Board (EDB) Nanyang Technological University The authors would like to thank NEWRI (Nanyang Technological University) and Singapore’s Economic Development Board (EDB) for their financial support of this research. 2021-08-02T07:46:43Z 2021-08-02T07:46:43Z 2020 Journal Article Krikstolaityte, V., Ding, R., Ruzgas, T., Björklund, S. & Lisak, G. (2020). Characterization of nano-layered solid-contact ion selective electrodes by simultaneous potentiometry and quartz crystal microbalance with dissipation. Analytica Chimica Acta, 1128, 19-30. https://dx.doi.org/10.1016/j.aca.2020.06.044 0003-2670 https://hdl.handle.net/10356/152051 10.1016/j.aca.2020.06.044 32825902 2-s2.0-85087993746 1128 19 30 en Analytica Chimica Acta © 2020 Elsevier B.V. All rights reserved.
spellingShingle Engineering::Environmental engineering
Potentiometry
Quartz Crystal Microbalance with Dissipation
Krikstolaityte, Vida
Ding, Ruiyu
Ruzgas, Tautgirdas
Björklund, Sebastian
Lisak, Grzegorz
Characterization of nano-layered solid-contact ion selective electrodes by simultaneous potentiometry and quartz crystal microbalance with dissipation
title Characterization of nano-layered solid-contact ion selective electrodes by simultaneous potentiometry and quartz crystal microbalance with dissipation
title_full Characterization of nano-layered solid-contact ion selective electrodes by simultaneous potentiometry and quartz crystal microbalance with dissipation
title_fullStr Characterization of nano-layered solid-contact ion selective electrodes by simultaneous potentiometry and quartz crystal microbalance with dissipation
title_full_unstemmed Characterization of nano-layered solid-contact ion selective electrodes by simultaneous potentiometry and quartz crystal microbalance with dissipation
title_short Characterization of nano-layered solid-contact ion selective electrodes by simultaneous potentiometry and quartz crystal microbalance with dissipation
title_sort characterization of nano layered solid contact ion selective electrodes by simultaneous potentiometry and quartz crystal microbalance with dissipation
topic Engineering::Environmental engineering
Potentiometry
Quartz Crystal Microbalance with Dissipation
url https://hdl.handle.net/10356/152051
work_keys_str_mv AT krikstolaitytevida characterizationofnanolayeredsolidcontactionselectiveelectrodesbysimultaneouspotentiometryandquartzcrystalmicrobalancewithdissipation
AT dingruiyu characterizationofnanolayeredsolidcontactionselectiveelectrodesbysimultaneouspotentiometryandquartzcrystalmicrobalancewithdissipation
AT ruzgastautgirdas characterizationofnanolayeredsolidcontactionselectiveelectrodesbysimultaneouspotentiometryandquartzcrystalmicrobalancewithdissipation
AT bjorklundsebastian characterizationofnanolayeredsolidcontactionselectiveelectrodesbysimultaneouspotentiometryandquartzcrystalmicrobalancewithdissipation
AT lisakgrzegorz characterizationofnanolayeredsolidcontactionselectiveelectrodesbysimultaneouspotentiometryandquartzcrystalmicrobalancewithdissipation