Three-step switching frequency selection criteria for the generalized CLLC-type DC transformer in hybrid AC-DC microgrid

For hybrid ac-dc microgrids, the widely applied high-frequency dc transformer (DCT) is usually scheduled to operate at resonant frequency with 50% duty-cycle-based semiregulated control to ensure the power transmission (PT), improve its power-density, and simplify the system-level control. However,...

全面介绍

书目详细资料
Main Authors: Huang, Jingjing, Zhang, Xin, Zhang, Zhe
其他作者: School of Electrical and Electronic Engineering
格式: Journal Article
语言:English
出版: 2022
主题: