Designing a portable, hand-held probe for retinal imaging

This project aims to create a portable handheld probe to capture retinal images to identify ocular diseases, primarily focusing on the detection on cataracts. In this report, a literature review of cataract and its prevalence around the world is discussed. Several retinal and fundus imaging methods...

Full description

Bibliographic Details
Main Author: Chua, Nigel Yue Zhuan
Other Authors: Murukeshan Vadakke Matham
Format: Final Year Project (FYP)
Language:English
Published: Nanyang Technological University 2022
Subjects:
Online Access:https://hdl.handle.net/10356/158641
_version_ 1811684783129886720
author Chua, Nigel Yue Zhuan
author2 Murukeshan Vadakke Matham
author_facet Murukeshan Vadakke Matham
Chua, Nigel Yue Zhuan
author_sort Chua, Nigel Yue Zhuan
collection NTU
description This project aims to create a portable handheld probe to capture retinal images to identify ocular diseases, primarily focusing on the detection on cataracts. In this report, a literature review of cataract and its prevalence around the world is discussed. Several retinal and fundus imaging methods are also reviewed for their advantages and disadvantages. Through this comparison, fundus photography is selected as the approach that the proposed handheld probe would adopt for the image capturing procedure. This is due to the capability of using small and lightweight components in this method and its ability easily record retinal images that can be reviewed later by clinicians. A preliminary investigation is conducted using an existing prototype probe, with the objective of the investigation being the familiarisation of the equipment, image capturing procedures and identification of key variables that needs to be optimised to produce high quality images of the retina. Subsequently, variations in parameters are made to improve the quality of images. These iterations include the positioning of the light source, optimizing the focal distance of the camera and developing techniques to reduce the strong specular reflections from the eye. Multiple variations are investigated before an optimized design is finalised to maximise strengths of each variant. The final probe prototype is 3D printed and custom written software is incorporated into the microcontroller that controls the probe operations such as image capturing and flashing of the light source for red reflex imaging. Images from a phantom eye model and ex-vivo porcine eye samples are captured, and the results are analysed. In the final section of the report, future work directions are proposed to further improve the effectiveness of the probe.
first_indexed 2024-10-01T04:34:07Z
format Final Year Project (FYP)
id ntu-10356/158641
institution Nanyang Technological University
language English
last_indexed 2024-10-01T04:34:07Z
publishDate 2022
publisher Nanyang Technological University
record_format dspace
spelling ntu-10356/1586412022-06-07T02:44:36Z Designing a portable, hand-held probe for retinal imaging Chua, Nigel Yue Zhuan Murukeshan Vadakke Matham School of Mechanical and Aerospace Engineering Suchand Sandeep Ahmad Khairyanto MMurukeshan@ntu.edu.sg, ssuchand@ntu.edu.sg, ahmadk@ntu.edu.sg Engineering::Mechanical engineering This project aims to create a portable handheld probe to capture retinal images to identify ocular diseases, primarily focusing on the detection on cataracts. In this report, a literature review of cataract and its prevalence around the world is discussed. Several retinal and fundus imaging methods are also reviewed for their advantages and disadvantages. Through this comparison, fundus photography is selected as the approach that the proposed handheld probe would adopt for the image capturing procedure. This is due to the capability of using small and lightweight components in this method and its ability easily record retinal images that can be reviewed later by clinicians. A preliminary investigation is conducted using an existing prototype probe, with the objective of the investigation being the familiarisation of the equipment, image capturing procedures and identification of key variables that needs to be optimised to produce high quality images of the retina. Subsequently, variations in parameters are made to improve the quality of images. These iterations include the positioning of the light source, optimizing the focal distance of the camera and developing techniques to reduce the strong specular reflections from the eye. Multiple variations are investigated before an optimized design is finalised to maximise strengths of each variant. The final probe prototype is 3D printed and custom written software is incorporated into the microcontroller that controls the probe operations such as image capturing and flashing of the light source for red reflex imaging. Images from a phantom eye model and ex-vivo porcine eye samples are captured, and the results are analysed. In the final section of the report, future work directions are proposed to further improve the effectiveness of the probe. Bachelor of Engineering (Mechanical Engineering) 2022-06-07T02:44:36Z 2022-06-07T02:44:36Z 2022 Final Year Project (FYP) Chua, N. Y. Z. (2022). Designing a portable, hand-held probe for retinal imaging. Final Year Project (FYP), Nanyang Technological University, Singapore. https://hdl.handle.net/10356/158641 https://hdl.handle.net/10356/158641 en A129 application/pdf Nanyang Technological University
spellingShingle Engineering::Mechanical engineering
Chua, Nigel Yue Zhuan
Designing a portable, hand-held probe for retinal imaging
title Designing a portable, hand-held probe for retinal imaging
title_full Designing a portable, hand-held probe for retinal imaging
title_fullStr Designing a portable, hand-held probe for retinal imaging
title_full_unstemmed Designing a portable, hand-held probe for retinal imaging
title_short Designing a portable, hand-held probe for retinal imaging
title_sort designing a portable hand held probe for retinal imaging
topic Engineering::Mechanical engineering
url https://hdl.handle.net/10356/158641
work_keys_str_mv AT chuanigelyuezhuan designingaportablehandheldprobeforretinalimaging