Systematic study of short circuit activation on the performance of PEM fuel cell

During the operation of proton exchange membrane fuel cell (PEMFC), it always suffers from reversible performance loss caused by the oxidation of platinum catalyst on its electrode, which reduces the electrochemical active surface area. Short circuit method has been found to improve the performance...