Performance analysis on the thermosiphon beam air conditioning and mechanical ventilation system

Air Conditioning and Mechanical Ventilation (ACMV) systems have been around for many years to provide cooling to many buildings around the world. However, due to the alarming rates of global warming, it is essential to develop new innovative ACMV technology to reduce the carbon emissions due to the...

Full description

Bibliographic Details
Main Author: Chia, Marcus Wen Jun
Other Authors: Wang Youyi
Format: Final Year Project (FYP)
Language:English
Published: Nanyang Technological University 2022
Subjects:
Online Access:https://hdl.handle.net/10356/163801
_version_ 1811677646365392896
author Chia, Marcus Wen Jun
author2 Wang Youyi
author_facet Wang Youyi
Chia, Marcus Wen Jun
author_sort Chia, Marcus Wen Jun
collection NTU
description Air Conditioning and Mechanical Ventilation (ACMV) systems have been around for many years to provide cooling to many buildings around the world. However, due to the alarming rates of global warming, it is essential to develop new innovative ACMV technology to reduce the carbon emissions due to the electrical consumption of the ACMVs. This report is based on the Thermosiphon Beam’s Air Conditioning and Mechanical Ventilation (TB ACMV) system which is developed in a joint research program with the School of Electrical and Electronics Engineering (EEE) and Energy Research Institute at Nanyang Technological University (ERI@N). It aims to explain how the TB ACMV system differs from the conventional ACMV system like the VAV AHU systems. The TB ACMV system is very versatile in handling both sensible and latent heat loads by splitting it into two major components, the Dedicated Outdoor Air System (DOAS) and the Thermosiphon Beam (TB). It also works with a higher chilled water temperature than the conventional ACMV system, hence reducing the overall energy consumption. The TB ACMV system also aims to improve Indoor Air Quality (IAQ) as well as ensure the thermal comfort of the occupants. The report would elaborate on how the TB ACMV is being controlled and how it is able to meet the required space heat loads with varying external air conditions.
first_indexed 2024-10-01T02:40:40Z
format Final Year Project (FYP)
id ntu-10356/163801
institution Nanyang Technological University
language English
last_indexed 2024-10-01T02:40:40Z
publishDate 2022
publisher Nanyang Technological University
record_format dspace
spelling ntu-10356/1638012023-07-07T19:33:02Z Performance analysis on the thermosiphon beam air conditioning and mechanical ventilation system Chia, Marcus Wen Jun Wang Youyi School of Electrical and Electronic Engineering EYYWANG@ntu.edu.sg Engineering::Electrical and electronic engineering::Electronic systems Air Conditioning and Mechanical Ventilation (ACMV) systems have been around for many years to provide cooling to many buildings around the world. However, due to the alarming rates of global warming, it is essential to develop new innovative ACMV technology to reduce the carbon emissions due to the electrical consumption of the ACMVs. This report is based on the Thermosiphon Beam’s Air Conditioning and Mechanical Ventilation (TB ACMV) system which is developed in a joint research program with the School of Electrical and Electronics Engineering (EEE) and Energy Research Institute at Nanyang Technological University (ERI@N). It aims to explain how the TB ACMV system differs from the conventional ACMV system like the VAV AHU systems. The TB ACMV system is very versatile in handling both sensible and latent heat loads by splitting it into two major components, the Dedicated Outdoor Air System (DOAS) and the Thermosiphon Beam (TB). It also works with a higher chilled water temperature than the conventional ACMV system, hence reducing the overall energy consumption. The TB ACMV system also aims to improve Indoor Air Quality (IAQ) as well as ensure the thermal comfort of the occupants. The report would elaborate on how the TB ACMV is being controlled and how it is able to meet the required space heat loads with varying external air conditions. Bachelor of Engineering (Electrical and Electronic Engineering) 2022-12-19T01:09:07Z 2022-12-19T01:09:07Z 2022 Final Year Project (FYP) Chia, M. W. J. (2022). Performance analysis on the thermosiphon beam air conditioning and mechanical ventilation system. Final Year Project (FYP), Nanyang Technological University, Singapore. https://hdl.handle.net/10356/163801 https://hdl.handle.net/10356/163801 en A1208-212 application/pdf Nanyang Technological University
spellingShingle Engineering::Electrical and electronic engineering::Electronic systems
Chia, Marcus Wen Jun
Performance analysis on the thermosiphon beam air conditioning and mechanical ventilation system
title Performance analysis on the thermosiphon beam air conditioning and mechanical ventilation system
title_full Performance analysis on the thermosiphon beam air conditioning and mechanical ventilation system
title_fullStr Performance analysis on the thermosiphon beam air conditioning and mechanical ventilation system
title_full_unstemmed Performance analysis on the thermosiphon beam air conditioning and mechanical ventilation system
title_short Performance analysis on the thermosiphon beam air conditioning and mechanical ventilation system
title_sort performance analysis on the thermosiphon beam air conditioning and mechanical ventilation system
topic Engineering::Electrical and electronic engineering::Electronic systems
url https://hdl.handle.net/10356/163801
work_keys_str_mv AT chiamarcuswenjun performanceanalysisonthethermosiphonbeamairconditioningandmechanicalventilationsystem