Multi-criteria assessments of increasing supply air temperature in tropical data center

With rapid development of information technology, the number and scale of data centers (DCs) increase rapidly. Therefore, cooling energy saving becomes crucial. This study proposes multi-criteria assessments of increasing supply air temperature (SAT) in the air-cooled DCs to analyze the interactions...

Full description

Bibliographic Details
Main Authors: Zhou, Jing, Kanbur, Baris Burak, Le, Duc Van, Tan, Rui, Duan, Fei
Other Authors: School of Mechanical and Aerospace Engineering
Format: Journal Article
Language:English
Published: 2023
Subjects:
Online Access:https://hdl.handle.net/10356/169073
_version_ 1826129875845513216
author Zhou, Jing
Kanbur, Baris Burak
Le, Duc Van
Tan, Rui
Duan, Fei
author2 School of Mechanical and Aerospace Engineering
author_facet School of Mechanical and Aerospace Engineering
Zhou, Jing
Kanbur, Baris Burak
Le, Duc Van
Tan, Rui
Duan, Fei
author_sort Zhou, Jing
collection NTU
description With rapid development of information technology, the number and scale of data centers (DCs) increase rapidly. Therefore, cooling energy saving becomes crucial. This study proposes multi-criteria assessments of increasing supply air temperature (SAT) in the air-cooled DCs to analyze the interactions of internal and external factors in cooling systems comprehensively. Impacts of refrigerant charge (RC), evaporation pressure (EP) control limits, and hot aisle containment (HAC) with improvements in SAT are compared and analyzed according to the thermodynamic, economic, and thermoeconomic aspects. Overall, as SAT increases from 20 °C to 32 °C, the power usage effectiveness decreases by 16.8%–19.3%. Increase in RC leads to energy consumption and cost increasing at high SAT ranges, whereas high RC shows obvious advantages at the low SAT from the thermoeconomic aspects. Additionally, releasing EP control limits has significant advantages in reducing energy usage, and cumulative present worth of data center testbed can decrease by 5.2% and 6.0% at low and high RC operations, respectively. Return on investment and payback period analysis are also performed in the testbed with the HAC reform, and the payback period is about 1–3 years with the SAT setting range at 20–32 °C.
first_indexed 2024-10-01T07:47:22Z
format Journal Article
id ntu-10356/169073
institution Nanyang Technological University
language English
last_indexed 2024-10-01T07:47:22Z
publishDate 2023
record_format dspace
spelling ntu-10356/1690732023-06-28T03:22:17Z Multi-criteria assessments of increasing supply air temperature in tropical data center Zhou, Jing Kanbur, Baris Burak Le, Duc Van Tan, Rui Duan, Fei School of Mechanical and Aerospace Engineering School of Computer Science and Engineering Engineering::Mechanical engineering Air-Cooled Data Center Energy Saving With rapid development of information technology, the number and scale of data centers (DCs) increase rapidly. Therefore, cooling energy saving becomes crucial. This study proposes multi-criteria assessments of increasing supply air temperature (SAT) in the air-cooled DCs to analyze the interactions of internal and external factors in cooling systems comprehensively. Impacts of refrigerant charge (RC), evaporation pressure (EP) control limits, and hot aisle containment (HAC) with improvements in SAT are compared and analyzed according to the thermodynamic, economic, and thermoeconomic aspects. Overall, as SAT increases from 20 °C to 32 °C, the power usage effectiveness decreases by 16.8%–19.3%. Increase in RC leads to energy consumption and cost increasing at high SAT ranges, whereas high RC shows obvious advantages at the low SAT from the thermoeconomic aspects. Additionally, releasing EP control limits has significant advantages in reducing energy usage, and cumulative present worth of data center testbed can decrease by 5.2% and 6.0% at low and high RC operations, respectively. Return on investment and payback period analysis are also performed in the testbed with the HAC reform, and the payback period is about 1–3 years with the SAT setting range at 20–32 °C. National Research Foundation (NRF) This project is supported by the National Research Foundation, Singapore, funded under Energy Research Test-Bed and Industry Partnership Funding Initiative, part of the Energy Grid (EG) 2.0 programme. 2023-06-28T03:22:16Z 2023-06-28T03:22:16Z 2023 Journal Article Zhou, J., Kanbur, B. B., Le, D. V., Tan, R. & Duan, F. (2023). Multi-criteria assessments of increasing supply air temperature in tropical data center. Energy, 271, 127043-. https://dx.doi.org/10.1016/j.energy.2023.127043 0360-5442 https://hdl.handle.net/10356/169073 10.1016/j.energy.2023.127043 2-s2.0-85149070053 271 127043 en Energy © 2023 Elsevier Ltd. All rights reserved.
spellingShingle Engineering::Mechanical engineering
Air-Cooled Data Center
Energy Saving
Zhou, Jing
Kanbur, Baris Burak
Le, Duc Van
Tan, Rui
Duan, Fei
Multi-criteria assessments of increasing supply air temperature in tropical data center
title Multi-criteria assessments of increasing supply air temperature in tropical data center
title_full Multi-criteria assessments of increasing supply air temperature in tropical data center
title_fullStr Multi-criteria assessments of increasing supply air temperature in tropical data center
title_full_unstemmed Multi-criteria assessments of increasing supply air temperature in tropical data center
title_short Multi-criteria assessments of increasing supply air temperature in tropical data center
title_sort multi criteria assessments of increasing supply air temperature in tropical data center
topic Engineering::Mechanical engineering
Air-Cooled Data Center
Energy Saving
url https://hdl.handle.net/10356/169073
work_keys_str_mv AT zhoujing multicriteriaassessmentsofincreasingsupplyairtemperatureintropicaldatacenter
AT kanburbarisburak multicriteriaassessmentsofincreasingsupplyairtemperatureintropicaldatacenter
AT leducvan multicriteriaassessmentsofincreasingsupplyairtemperatureintropicaldatacenter
AT tanrui multicriteriaassessmentsofincreasingsupplyairtemperatureintropicaldatacenter
AT duanfei multicriteriaassessmentsofincreasingsupplyairtemperatureintropicaldatacenter