Design & build a protection relay test set

In electrical installations on the main switchboards, protection relays like Overcurrent Relays, Earth Fault Relays, etc. are installed after a Circuit Breaker (CB), designed to trip the respective CB when a fault is detected to protect the end-user / equipment. Shutdown maintenances are carried...

Full description

Bibliographic Details
Main Author: Ong, Vivian Yu Qi
Other Authors: Ling Keck Voon
Format: Final Year Project (FYP)
Language:English
Published: Nanyang Technological University 2023
Subjects:
Online Access:https://hdl.handle.net/10356/172690
_version_ 1826125913813680128
author Ong, Vivian Yu Qi
author2 Ling Keck Voon
author_facet Ling Keck Voon
Ong, Vivian Yu Qi
author_sort Ong, Vivian Yu Qi
collection NTU
description In electrical installations on the main switchboards, protection relays like Overcurrent Relays, Earth Fault Relays, etc. are installed after a Circuit Breaker (CB), designed to trip the respective CB when a fault is detected to protect the end-user / equipment. Shutdown maintenances are carried out periodically on most electrical installation to test the functionality of components within the electrical installations. As part of the shutdown maintenance work, Secondary Injection (SI) tests are carried out on the protection relays to ensure that the relays are still functioning. Protection relays to be tested can be as much as a hundred relays, all to be tested within a tight time frame. Protection relays found/tested faulty will be highlighted and seek approval from client for immediate replacement. Getting the approval from client will often take time, hence time taken to finish testing all relays is essential. This is to ensure that faulty relays can be replaced within scheduled shutdown timings to avoid delays in restoration of power supply to the estate. The test set that are usually used for the protection relay testing is costly and bulky as it can also carry out other different tests such as Primary Injection test, SI testing of three phase relays which are used in the higher voltage installation. Weighing at more than 20 kilograms (kg), a lot of time and effort is spent moving the bulky and heavy test set around. Regardless of the estate intake capacity, most of them will have a Low Tension (LT) switchboard, up to 400 Volts(V) three-phase line to line, before distribution of power to consumers. Hence, it is very common and mostly only single-phase protection relays to be tested. The other various tests that the bulky test set offers are not required. Hence, the aim of this project is to build a smaller and cheaper SI test set.
first_indexed 2024-10-01T06:44:29Z
format Final Year Project (FYP)
id ntu-10356/172690
institution Nanyang Technological University
language English
last_indexed 2024-10-01T06:44:29Z
publishDate 2023
publisher Nanyang Technological University
record_format dspace
spelling ntu-10356/1726902023-12-22T15:43:22Z Design & build a protection relay test set Ong, Vivian Yu Qi Ling Keck Voon School of Electrical and Electronic Engineering EKVLING@ntu.edu.sg Engineering::Electrical and electronic engineering::Electric power Engineering::Electrical and electronic engineering::Electric apparatus and materials In electrical installations on the main switchboards, protection relays like Overcurrent Relays, Earth Fault Relays, etc. are installed after a Circuit Breaker (CB), designed to trip the respective CB when a fault is detected to protect the end-user / equipment. Shutdown maintenances are carried out periodically on most electrical installation to test the functionality of components within the electrical installations. As part of the shutdown maintenance work, Secondary Injection (SI) tests are carried out on the protection relays to ensure that the relays are still functioning. Protection relays to be tested can be as much as a hundred relays, all to be tested within a tight time frame. Protection relays found/tested faulty will be highlighted and seek approval from client for immediate replacement. Getting the approval from client will often take time, hence time taken to finish testing all relays is essential. This is to ensure that faulty relays can be replaced within scheduled shutdown timings to avoid delays in restoration of power supply to the estate. The test set that are usually used for the protection relay testing is costly and bulky as it can also carry out other different tests such as Primary Injection test, SI testing of three phase relays which are used in the higher voltage installation. Weighing at more than 20 kilograms (kg), a lot of time and effort is spent moving the bulky and heavy test set around. Regardless of the estate intake capacity, most of them will have a Low Tension (LT) switchboard, up to 400 Volts(V) three-phase line to line, before distribution of power to consumers. Hence, it is very common and mostly only single-phase protection relays to be tested. The other various tests that the bulky test set offers are not required. Hence, the aim of this project is to build a smaller and cheaper SI test set. Bachelor of Engineering (Electrical and Electronic Engineering) 2023-12-18T06:08:53Z 2023-12-18T06:08:53Z 2023 Final Year Project (FYP) Ong, V. Y. Q. (2023). Design & build a protection relay test set. Final Year Project (FYP), Nanyang Technological University, Singapore. https://hdl.handle.net/10356/172690 https://hdl.handle.net/10356/172690 en P1003-221 application/pdf Nanyang Technological University
spellingShingle Engineering::Electrical and electronic engineering::Electric power
Engineering::Electrical and electronic engineering::Electric apparatus and materials
Ong, Vivian Yu Qi
Design & build a protection relay test set
title Design & build a protection relay test set
title_full Design & build a protection relay test set
title_fullStr Design & build a protection relay test set
title_full_unstemmed Design & build a protection relay test set
title_short Design & build a protection relay test set
title_sort design build a protection relay test set
topic Engineering::Electrical and electronic engineering::Electric power
Engineering::Electrical and electronic engineering::Electric apparatus and materials
url https://hdl.handle.net/10356/172690
work_keys_str_mv AT ongvivianyuqi designbuildaprotectionrelaytestset