Develop an online system for 66KV sheath fault detection/location

This collaborative project involves SP Group and Nanyang Technological University, focusing on detecting faults in the cable sheaths of underground cables. Regular testing of underground cables is crucial to ensure their integrity and maintain stable power transmission. However, the current process...

Szczegółowa specyfikacja

Opis bibliograficzny
1. autor: Ahmad Waliyuddin Bin Jumat
Kolejni autorzy: Foo Yi Shyh, Eddy
Format: Final Year Project (FYP)
Język:English
Wydane: Nanyang Technological University 2024
Hasła przedmiotowe:
Dostęp online:https://hdl.handle.net/10356/176577
_version_ 1826123845349670912
author Ahmad Waliyuddin Bin Jumat
author2 Foo Yi Shyh, Eddy
author_facet Foo Yi Shyh, Eddy
Ahmad Waliyuddin Bin Jumat
author_sort Ahmad Waliyuddin Bin Jumat
collection NTU
description This collaborative project involves SP Group and Nanyang Technological University, focusing on detecting faults in the cable sheaths of underground cables. Regular testing of underground cables is crucial to ensure their integrity and maintain stable power transmission. However, the current process for conducting cable sheath tests is labor-intensive, costly, and time-consuming. It involves pre-checking link boxes along the cable route, which can take several days due to their numerous locations and weather conditions since the testing will be carried out outdoors. Each link box serves as a connection point between cables where the power cables meet and joint. Once the site survey for the link box locations is completed, the circuit must be shutdown before conducting the sheath test, which involves injecting a 1kV DC voltage into the cable sheath to test its withstand voltage. The testing team will then inspect each link box for anomalies detected during the insulation resistance and leakage current tests. If the sheath fails to withstand the 1kV for 1 minute, it is considered as a failed test and deemed as sheath fault is present at that specific span that was tested. This testing process can be improve as the current method only be done when the circuit has been shutdown, which in turn, limits the monitoring window to know the health of the cable sheath. Sheath fault can occur at any time without human interference. Therefore, the project aims to develop a new solution for conducting online cable sheath checks without the need for shutdown. Given the absence of existing products or ideas for an online system to detect or locate sheath faults in 66kV cables, extensive research has been undertaken in this project. The research in this project includes probing into testing methods such as acoustic and ultrasound and the devices and parts required to carry out the testing of the circuit. Further testing on site is carried out to better pinpoint the areas to be improved on the errors encountered while testing. 
first_indexed 2024-10-01T06:10:59Z
format Final Year Project (FYP)
id ntu-10356/176577
institution Nanyang Technological University
language English
last_indexed 2024-10-01T06:10:59Z
publishDate 2024
publisher Nanyang Technological University
record_format dspace
spelling ntu-10356/1765772024-05-24T15:49:51Z Develop an online system for 66KV sheath fault detection/location Ahmad Waliyuddin Bin Jumat Foo Yi Shyh, Eddy School of Electrical and Electronic Engineering EddyFoo@ntu.edu.sg Engineering This collaborative project involves SP Group and Nanyang Technological University, focusing on detecting faults in the cable sheaths of underground cables. Regular testing of underground cables is crucial to ensure their integrity and maintain stable power transmission. However, the current process for conducting cable sheath tests is labor-intensive, costly, and time-consuming. It involves pre-checking link boxes along the cable route, which can take several days due to their numerous locations and weather conditions since the testing will be carried out outdoors. Each link box serves as a connection point between cables where the power cables meet and joint. Once the site survey for the link box locations is completed, the circuit must be shutdown before conducting the sheath test, which involves injecting a 1kV DC voltage into the cable sheath to test its withstand voltage. The testing team will then inspect each link box for anomalies detected during the insulation resistance and leakage current tests. If the sheath fails to withstand the 1kV for 1 minute, it is considered as a failed test and deemed as sheath fault is present at that specific span that was tested. This testing process can be improve as the current method only be done when the circuit has been shutdown, which in turn, limits the monitoring window to know the health of the cable sheath. Sheath fault can occur at any time without human interference. Therefore, the project aims to develop a new solution for conducting online cable sheath checks without the need for shutdown. Given the absence of existing products or ideas for an online system to detect or locate sheath faults in 66kV cables, extensive research has been undertaken in this project. The research in this project includes probing into testing methods such as acoustic and ultrasound and the devices and parts required to carry out the testing of the circuit. Further testing on site is carried out to better pinpoint the areas to be improved on the errors encountered while testing.  Bachelor's degree 2024-05-18T10:31:13Z 2024-05-18T10:31:13Z 2024 Final Year Project (FYP) Ahmad Waliyuddin Bin Jumat (2024). Develop an online system for 66KV sheath fault detection/location. Final Year Project (FYP), Nanyang Technological University, Singapore. https://hdl.handle.net/10356/176577 https://hdl.handle.net/10356/176577 en P1044-222 application/pdf Nanyang Technological University
spellingShingle Engineering
Ahmad Waliyuddin Bin Jumat
Develop an online system for 66KV sheath fault detection/location
title Develop an online system for 66KV sheath fault detection/location
title_full Develop an online system for 66KV sheath fault detection/location
title_fullStr Develop an online system for 66KV sheath fault detection/location
title_full_unstemmed Develop an online system for 66KV sheath fault detection/location
title_short Develop an online system for 66KV sheath fault detection/location
title_sort develop an online system for 66kv sheath fault detection location
topic Engineering
url https://hdl.handle.net/10356/176577
work_keys_str_mv AT ahmadwaliyuddinbinjumat developanonlinesystemfor66kvsheathfaultdetectionlocation