Design and development of a cross-sectional area sensor via impedance measurement

The importance of the cardiac output as a measured parameter is that it can be used to evaluate the overall cardiac status in both critically ill patients and patients with suspected cardiovascular disease. Although there are several methods for determining the cardiac output, these methods do not a...

Full description

Bibliographic Details
Main Author: Xie, Tu Qiang.
Other Authors: Tjin, Swee Chuan
Format: Thesis
Language:English
Published: 2009
Subjects:
Online Access:http://hdl.handle.net/10356/19588
_version_ 1826126162798051328
author Xie, Tu Qiang.
author2 Tjin, Swee Chuan
author_facet Tjin, Swee Chuan
Xie, Tu Qiang.
author_sort Xie, Tu Qiang.
collection NTU
description The importance of the cardiac output as a measured parameter is that it can be used to evaluate the overall cardiac status in both critically ill patients and patients with suspected cardiovascular disease. Although there are several methods for determining the cardiac output, these methods do not allow for a continuous real-time measurement of the cardiac output for both steady and pulsatile blood flow. By combining the impedance measurement technique and velocity measurement technique, an alternative method of cardiac output measurement is proposed. In this method, a catheter, which comprises a cross-sectional area (CSA) sensor and a velocity sensor, and is to be inserted into artery. The product of blood velocity and vessel's cross-sectional area is the cardiac output.
first_indexed 2024-10-01T06:48:30Z
format Thesis
id ntu-10356/19588
institution Nanyang Technological University
language English
last_indexed 2024-10-01T06:48:30Z
publishDate 2009
record_format dspace
spelling ntu-10356/195882023-07-04T15:25:46Z Design and development of a cross-sectional area sensor via impedance measurement Xie, Tu Qiang. Tjin, Swee Chuan School of Electrical and Electronic Engineering DRNTU::Engineering::Electrical and electronic engineering::Electronic systems The importance of the cardiac output as a measured parameter is that it can be used to evaluate the overall cardiac status in both critically ill patients and patients with suspected cardiovascular disease. Although there are several methods for determining the cardiac output, these methods do not allow for a continuous real-time measurement of the cardiac output for both steady and pulsatile blood flow. By combining the impedance measurement technique and velocity measurement technique, an alternative method of cardiac output measurement is proposed. In this method, a catheter, which comprises a cross-sectional area (CSA) sensor and a velocity sensor, and is to be inserted into artery. The product of blood velocity and vessel's cross-sectional area is the cardiac output. Master of Engineering 2009-12-14T06:16:42Z 2009-12-14T06:16:42Z 1997 1997 Thesis http://hdl.handle.net/10356/19588 en NANYANG TECHNOLOGICAL UNIVERSITY 107 p. application/pdf
spellingShingle DRNTU::Engineering::Electrical and electronic engineering::Electronic systems
Xie, Tu Qiang.
Design and development of a cross-sectional area sensor via impedance measurement
title Design and development of a cross-sectional area sensor via impedance measurement
title_full Design and development of a cross-sectional area sensor via impedance measurement
title_fullStr Design and development of a cross-sectional area sensor via impedance measurement
title_full_unstemmed Design and development of a cross-sectional area sensor via impedance measurement
title_short Design and development of a cross-sectional area sensor via impedance measurement
title_sort design and development of a cross sectional area sensor via impedance measurement
topic DRNTU::Engineering::Electrical and electronic engineering::Electronic systems
url http://hdl.handle.net/10356/19588
work_keys_str_mv AT xietuqiang designanddevelopmentofacrosssectionalareasensorviaimpedancemeasurement