Finite element analysis of shoulder rotator cuff

This final year project aims to create a feasible three-dimensional (3D) model of the human shoulder Rotator Cuff and its four tendons – Subscapularis, Supraspinatus, Infraspinatus and Teres Minor. The resulting computerized models are to be subsequently utilized for the Finite Element Analysis (...

Full description

Bibliographic Details
Main Author: Phone, Myint Aung.
Other Authors: Tan Soon Huat
Format: Final Year Project (FYP)
Language:English
Published: 2010
Subjects:
Online Access:http://hdl.handle.net/10356/20724
_version_ 1811681236223000576
author Phone, Myint Aung.
author2 Tan Soon Huat
author_facet Tan Soon Huat
Phone, Myint Aung.
author_sort Phone, Myint Aung.
collection NTU
description This final year project aims to create a feasible three-dimensional (3D) model of the human shoulder Rotator Cuff and its four tendons – Subscapularis, Supraspinatus, Infraspinatus and Teres Minor. The resulting computerized models are to be subsequently utilized for the Finite Element Analysis (FEA) – an attempt to simulate force, stress and strain distribution patterns that the human shoulder joint undergoes in different scenarios. The ultimate aim is to practically but virtually simulate the origination and consequences of muscular tears in the shoulder region which become a common problem in the aged people and in those subjected to repeated or excessive use. This project is in fact a continuation from the past year’s project. The senior student had already set up a basic methodology on creating 3D models from MRI Images. He had successfully created the three-dimensional model of rotator cuff. However, due to the limitations he had, such as the poor resolution of the MRI images he was provided with, he did not complete modeling of the four tendons. Nevertheless, the author finds that the senior’s contribution has been very helpful – a very good standing ground to start off with. The author, likewise, continues to makes use of MIMICS (Materialise’s Interactive Medical Image Control System) software version 10 since it is still the best tool available within the reach. For the choices of subsequent model pre-processing softwares, the author ventures into different paths by varying combinations of softwares to come up with the most convenient way of “getting it done” without compensating the accuracy of the models. The main 3D pre-processor which will be utilized is SolidWorks® 2009. Finally, after getting the model done, the author intends to countercheck the workability of the created models in FEA applications such as ANSYS®, Abaqus® or any other well-recognized FEA tools.
first_indexed 2024-10-01T03:37:44Z
format Final Year Project (FYP)
id ntu-10356/20724
institution Nanyang Technological University
language English
last_indexed 2024-10-01T03:37:44Z
publishDate 2010
record_format dspace
spelling ntu-10356/207242023-03-04T18:17:33Z Finite element analysis of shoulder rotator cuff Phone, Myint Aung. Tan Soon Huat School of Mechanical and Aerospace Engineering DRNTU::Engineering::Mechanical engineering::Surgical assistive technology This final year project aims to create a feasible three-dimensional (3D) model of the human shoulder Rotator Cuff and its four tendons – Subscapularis, Supraspinatus, Infraspinatus and Teres Minor. The resulting computerized models are to be subsequently utilized for the Finite Element Analysis (FEA) – an attempt to simulate force, stress and strain distribution patterns that the human shoulder joint undergoes in different scenarios. The ultimate aim is to practically but virtually simulate the origination and consequences of muscular tears in the shoulder region which become a common problem in the aged people and in those subjected to repeated or excessive use. This project is in fact a continuation from the past year’s project. The senior student had already set up a basic methodology on creating 3D models from MRI Images. He had successfully created the three-dimensional model of rotator cuff. However, due to the limitations he had, such as the poor resolution of the MRI images he was provided with, he did not complete modeling of the four tendons. Nevertheless, the author finds that the senior’s contribution has been very helpful – a very good standing ground to start off with. The author, likewise, continues to makes use of MIMICS (Materialise’s Interactive Medical Image Control System) software version 10 since it is still the best tool available within the reach. For the choices of subsequent model pre-processing softwares, the author ventures into different paths by varying combinations of softwares to come up with the most convenient way of “getting it done” without compensating the accuracy of the models. The main 3D pre-processor which will be utilized is SolidWorks® 2009. Finally, after getting the model done, the author intends to countercheck the workability of the created models in FEA applications such as ANSYS®, Abaqus® or any other well-recognized FEA tools. Bachelor of Engineering (Mechanical Engineering) 2010-01-06T07:20:20Z 2010-01-06T07:20:20Z 2009 2009 Final Year Project (FYP) http://hdl.handle.net/10356/20724 en Nanyang Technological University 112 p. application/pdf
spellingShingle DRNTU::Engineering::Mechanical engineering::Surgical assistive technology
Phone, Myint Aung.
Finite element analysis of shoulder rotator cuff
title Finite element analysis of shoulder rotator cuff
title_full Finite element analysis of shoulder rotator cuff
title_fullStr Finite element analysis of shoulder rotator cuff
title_full_unstemmed Finite element analysis of shoulder rotator cuff
title_short Finite element analysis of shoulder rotator cuff
title_sort finite element analysis of shoulder rotator cuff
topic DRNTU::Engineering::Mechanical engineering::Surgical assistive technology
url http://hdl.handle.net/10356/20724
work_keys_str_mv AT phonemyintaung finiteelementanalysisofshoulderrotatorcuff