Relaxation and frequency response analysis studies on power equipment
The main objective of this research project is to study the relaxation processes in various power apparatus of two power-generating plants with Recovery Voltage Measurement (RVM) and Polarization Current Measurement (PCM) techniques and to develop an automated technqiue to identify winding faults an...
Main Author: | |
---|---|
Other Authors: | |
Format: | Thesis |
Published: |
2008
|
Subjects: | |
Online Access: | http://hdl.handle.net/10356/3941 |
_version_ | 1826128592625467392 |
---|---|
author | Yu, Xingzhou. |
author2 | Birlasekaran, Sivaswamy |
author_facet | Birlasekaran, Sivaswamy Yu, Xingzhou. |
author_sort | Yu, Xingzhou. |
collection | NTU |
description | The main objective of this research project is to study the relaxation processes in various power apparatus of two power-generating plants with Recovery Voltage Measurement (RVM) and Polarization Current Measurement (PCM) techniques and to develop an automated technqiue to identify winding faults and severity of a transformer using Frequency Response Analysis (FRA) technqiue. |
first_indexed | 2024-10-01T07:27:27Z |
format | Thesis |
id | ntu-10356/3941 |
institution | Nanyang Technological University |
last_indexed | 2024-10-01T07:27:27Z |
publishDate | 2008 |
record_format | dspace |
spelling | ntu-10356/39412023-07-04T15:21:01Z Relaxation and frequency response analysis studies on power equipment Yu, Xingzhou. Birlasekaran, Sivaswamy School of Electrical and Electronic Engineering DRNTU::Engineering::Electrical and electronic engineering::Electric power::Production, transmission and distribution The main objective of this research project is to study the relaxation processes in various power apparatus of two power-generating plants with Recovery Voltage Measurement (RVM) and Polarization Current Measurement (PCM) techniques and to develop an automated technqiue to identify winding faults and severity of a transformer using Frequency Response Analysis (FRA) technqiue. Master of Engineering 2008-09-17T09:40:50Z 2008-09-17T09:40:50Z 2001 2001 Thesis http://hdl.handle.net/10356/3941 Nanyang Technological University application/pdf |
spellingShingle | DRNTU::Engineering::Electrical and electronic engineering::Electric power::Production, transmission and distribution Yu, Xingzhou. Relaxation and frequency response analysis studies on power equipment |
title | Relaxation and frequency response analysis studies on power equipment |
title_full | Relaxation and frequency response analysis studies on power equipment |
title_fullStr | Relaxation and frequency response analysis studies on power equipment |
title_full_unstemmed | Relaxation and frequency response analysis studies on power equipment |
title_short | Relaxation and frequency response analysis studies on power equipment |
title_sort | relaxation and frequency response analysis studies on power equipment |
topic | DRNTU::Engineering::Electrical and electronic engineering::Electric power::Production, transmission and distribution |
url | http://hdl.handle.net/10356/3941 |
work_keys_str_mv | AT yuxingzhou relaxationandfrequencyresponseanalysisstudiesonpowerequipment |