Study and analysis of different contact materials for ohmic RF MEMS switch

MicroElectroMechanical Systems (MEMS) are integrated micro devices or systems combining electrical and mechanical components that can sense, control, and actuate on the micro scale and function individually or in arrays to generate effects on the macro scale. MEMS is one of the most promising areas...

Full description

Bibliographic Details
Main Author: Raihanah Abdul Razak
Other Authors: Wang Hong
Format: Final Year Project (FYP)
Language:English
Published: 2011
Subjects:
Online Access:http://hdl.handle.net/10356/46085
_version_ 1826120481199095808
author Raihanah Abdul Razak
author2 Wang Hong
author_facet Wang Hong
Raihanah Abdul Razak
author_sort Raihanah Abdul Razak
collection NTU
description MicroElectroMechanical Systems (MEMS) are integrated micro devices or systems combining electrical and mechanical components that can sense, control, and actuate on the micro scale and function individually or in arrays to generate effects on the macro scale. MEMS is one of the most promising areas in future computer and machinery, the next logical step in the silicon revolution. Fabricated using Integrated Circuit (IC) compatible batch-processing techniques, the small size of MEMS opens a new line of exciting applications. Reliability is of concern if MEMS machinery is used in critical applications. MEMS technology is still in its infancy, like IC technology 30 years ago. Focus has been put in wafer level reliability, the same path taken in the IC technology. Presently how MEMS fail is still not well understood. Study and analysis of contact behavior of ohmic RF MEMS switch are investigated in this project. Using a piezoactuator, with a metal tip mounted on it, and a gold wafer is used to conduct the ohmic contact instead of fabrication of MEMS switch. Data are collected to observe the transition period during contact-making process. Statistical analysis through amplitude histogram is performed. The current and contact resistance is also being analyzed to observe the phenomenon during the contact-making process. In addition, wafers of different roughness are tested and results have shown that the rougher the surface, the longer the transition period and the more fluctuations it has.
first_indexed 2024-10-01T05:17:28Z
format Final Year Project (FYP)
id ntu-10356/46085
institution Nanyang Technological University
language English
last_indexed 2024-10-01T05:17:28Z
publishDate 2011
record_format dspace
spelling ntu-10356/460852023-07-07T16:46:38Z Study and analysis of different contact materials for ohmic RF MEMS switch Raihanah Abdul Razak Wang Hong School of Electrical and Electronic Engineering DRNTU::Engineering::Electrical and electronic engineering::Microelectromechanical systems MicroElectroMechanical Systems (MEMS) are integrated micro devices or systems combining electrical and mechanical components that can sense, control, and actuate on the micro scale and function individually or in arrays to generate effects on the macro scale. MEMS is one of the most promising areas in future computer and machinery, the next logical step in the silicon revolution. Fabricated using Integrated Circuit (IC) compatible batch-processing techniques, the small size of MEMS opens a new line of exciting applications. Reliability is of concern if MEMS machinery is used in critical applications. MEMS technology is still in its infancy, like IC technology 30 years ago. Focus has been put in wafer level reliability, the same path taken in the IC technology. Presently how MEMS fail is still not well understood. Study and analysis of contact behavior of ohmic RF MEMS switch are investigated in this project. Using a piezoactuator, with a metal tip mounted on it, and a gold wafer is used to conduct the ohmic contact instead of fabrication of MEMS switch. Data are collected to observe the transition period during contact-making process. Statistical analysis through amplitude histogram is performed. The current and contact resistance is also being analyzed to observe the phenomenon during the contact-making process. In addition, wafers of different roughness are tested and results have shown that the rougher the surface, the longer the transition period and the more fluctuations it has. Bachelor of Engineering 2011-06-28T09:21:17Z 2011-06-28T09:21:17Z 2011 2011 Final Year Project (FYP) http://hdl.handle.net/10356/46085 en Nanyang Technological University 67 p. application/pdf
spellingShingle DRNTU::Engineering::Electrical and electronic engineering::Microelectromechanical systems
Raihanah Abdul Razak
Study and analysis of different contact materials for ohmic RF MEMS switch
title Study and analysis of different contact materials for ohmic RF MEMS switch
title_full Study and analysis of different contact materials for ohmic RF MEMS switch
title_fullStr Study and analysis of different contact materials for ohmic RF MEMS switch
title_full_unstemmed Study and analysis of different contact materials for ohmic RF MEMS switch
title_short Study and analysis of different contact materials for ohmic RF MEMS switch
title_sort study and analysis of different contact materials for ohmic rf mems switch
topic DRNTU::Engineering::Electrical and electronic engineering::Microelectromechanical systems
url http://hdl.handle.net/10356/46085
work_keys_str_mv AT raihanahabdulrazak studyandanalysisofdifferentcontactmaterialsforohmicrfmemsswitch