Design an Interfacing mechanism for a water bolus with base-unit

ABSTRACT In recent years, High Intensity Focused Ultrasound (HIFU) has emerged as a non-invasive surgical modality and also through understanding of the physical principles in the interactions of HIFU with biological tissue in parallel with the progress in transducer technology, the developme...

Full description

Bibliographic Details
Main Author: Liu, GaoQiang.
Other Authors: Sunita Chauhan
Format: Final Year Project (FYP)
Language:English
Published: 2012
Subjects:
Online Access:http://hdl.handle.net/10356/47713
_version_ 1811687655740538880
author Liu, GaoQiang.
author2 Sunita Chauhan
author_facet Sunita Chauhan
Liu, GaoQiang.
author_sort Liu, GaoQiang.
collection NTU
description ABSTRACT In recent years, High Intensity Focused Ultrasound (HIFU) has emerged as a non-invasive surgical modality and also through understanding of the physical principles in the interactions of HIFU with biological tissue in parallel with the progress in transducer technology, the development towards the adoption of HIFU approach promising in permitting contact-free in-depth tissue accessible for ultrasound. In addition to that, robotic techniques are looked into to provide complex maneuver that can achieve the objectives of precise and accurate mechanical manipulations in various configurations. With robot assistance into the surgical arena, it allows surgeon to work with greater accuracy. A interaction robotic with HIFU system will provide great feasibility for surgery dealing with brain tumours. The aim of this project is to understand the existing design of water bolus and base unit. Thereafter design an integrated interface unit for water bolus with base unit, which will be used in brain tumour treatments. Design procedures such as function analysis, morphological chart are used. Conceptual designs were generated and configurations were discussed. The selections of designs were based on analytical evaluations of various designs. Calculation of critical areas was done. Simulation and selection of parts were involved to determine the feasibility of the design. Testing was carried out for the prototype using Galil Controller and thus achieved the objective.
first_indexed 2024-10-01T05:19:46Z
format Final Year Project (FYP)
id ntu-10356/47713
institution Nanyang Technological University
language English
last_indexed 2024-10-01T05:19:46Z
publishDate 2012
record_format dspace
spelling ntu-10356/477132023-03-04T19:00:05Z Design an Interfacing mechanism for a water bolus with base-unit Liu, GaoQiang. Sunita Chauhan School of Mechanical and Aerospace Engineering DRNTU::Engineering::Mechanical engineering ABSTRACT In recent years, High Intensity Focused Ultrasound (HIFU) has emerged as a non-invasive surgical modality and also through understanding of the physical principles in the interactions of HIFU with biological tissue in parallel with the progress in transducer technology, the development towards the adoption of HIFU approach promising in permitting contact-free in-depth tissue accessible for ultrasound. In addition to that, robotic techniques are looked into to provide complex maneuver that can achieve the objectives of precise and accurate mechanical manipulations in various configurations. With robot assistance into the surgical arena, it allows surgeon to work with greater accuracy. A interaction robotic with HIFU system will provide great feasibility for surgery dealing with brain tumours. The aim of this project is to understand the existing design of water bolus and base unit. Thereafter design an integrated interface unit for water bolus with base unit, which will be used in brain tumour treatments. Design procedures such as function analysis, morphological chart are used. Conceptual designs were generated and configurations were discussed. The selections of designs were based on analytical evaluations of various designs. Calculation of critical areas was done. Simulation and selection of parts were involved to determine the feasibility of the design. Testing was carried out for the prototype using Galil Controller and thus achieved the objective. Bachelor of Engineering (Mechanical Engineering) 2012-01-26T01:38:06Z 2012-01-26T01:38:06Z 2011 2011 Final Year Project (FYP) http://hdl.handle.net/10356/47713 en Nanyang Technological University 79 p. application/pdf
spellingShingle DRNTU::Engineering::Mechanical engineering
Liu, GaoQiang.
Design an Interfacing mechanism for a water bolus with base-unit
title Design an Interfacing mechanism for a water bolus with base-unit
title_full Design an Interfacing mechanism for a water bolus with base-unit
title_fullStr Design an Interfacing mechanism for a water bolus with base-unit
title_full_unstemmed Design an Interfacing mechanism for a water bolus with base-unit
title_short Design an Interfacing mechanism for a water bolus with base-unit
title_sort design an interfacing mechanism for a water bolus with base unit
topic DRNTU::Engineering::Mechanical engineering
url http://hdl.handle.net/10356/47713
work_keys_str_mv AT liugaoqiang designaninterfacingmechanismforawaterboluswithbaseunit