Vibration of membrane modules for low pressure membrane process

Vibrating process in submerged membrane system has the potential to overcome limitations such as fouling potentiality and high energy consumption. However, vibration mechanism is not widely understood and especially so in the filtration process of yeast solution. The main aim of this project study i...

Full description

Bibliographic Details
Main Author: Tan, Li Lian.
Other Authors: Law Wing-Keung, Adrian
Format: Final Year Project (FYP)
Language:English
Published: 2012
Subjects:
Online Access:http://hdl.handle.net/10356/49189
_version_ 1811680956142059520
author Tan, Li Lian.
author2 Law Wing-Keung, Adrian
author_facet Law Wing-Keung, Adrian
Tan, Li Lian.
author_sort Tan, Li Lian.
collection NTU
description Vibrating process in submerged membrane system has the potential to overcome limitations such as fouling potentiality and high energy consumption. However, vibration mechanism is not widely understood and especially so in the filtration process of yeast solution. The main aim of this project study is to investigate the efficiency of vibration in the filtration process of yeast suspension. Different amplitudes and frequencies, degree of tightness of membrane fibers were operating parameters used in the filtration system in the laboratory. With unwashed yeasts, increment in amplitudes had a better fouling control than increment in frequencies. With washed yeast, however with increment in frequency, the fouling rate was better reduced. Without the presence of potential fouling agents, washed yeasts fouling rates were reduced significantly coupled with an increase in frequency. Vibration effectiveness in bentonite, unwashed and washed yeast solutions was proven to be achievable with increase in frequency and amplitude. However, more run tests will have to be conducted for yeast suspension. Experiments conducted to investigate the supporting frame for membrane fibers, which was suspected to introduce turbulence into the feed solution and enhance the hydrodynamic condition, had shown that the frame had negligible effect. It is evident that the vibration technique with optimize frequency and amplitude can reduce fouling rates in both organic and inorganic solutions. However, further understanding of fouling mechanism in organic solutions has to be studied for its full applicability in vibration membrane system.
first_indexed 2024-10-01T03:33:17Z
format Final Year Project (FYP)
id ntu-10356/49189
institution Nanyang Technological University
language English
last_indexed 2024-10-01T03:33:17Z
publishDate 2012
record_format dspace
spelling ntu-10356/491892023-03-03T17:18:42Z Vibration of membrane modules for low pressure membrane process Tan, Li Lian. Law Wing-Keung, Adrian School of Civil and Environmental Engineering DRNTU::Engineering::Environmental engineering::Water treatment Vibrating process in submerged membrane system has the potential to overcome limitations such as fouling potentiality and high energy consumption. However, vibration mechanism is not widely understood and especially so in the filtration process of yeast solution. The main aim of this project study is to investigate the efficiency of vibration in the filtration process of yeast suspension. Different amplitudes and frequencies, degree of tightness of membrane fibers were operating parameters used in the filtration system in the laboratory. With unwashed yeasts, increment in amplitudes had a better fouling control than increment in frequencies. With washed yeast, however with increment in frequency, the fouling rate was better reduced. Without the presence of potential fouling agents, washed yeasts fouling rates were reduced significantly coupled with an increase in frequency. Vibration effectiveness in bentonite, unwashed and washed yeast solutions was proven to be achievable with increase in frequency and amplitude. However, more run tests will have to be conducted for yeast suspension. Experiments conducted to investigate the supporting frame for membrane fibers, which was suspected to introduce turbulence into the feed solution and enhance the hydrodynamic condition, had shown that the frame had negligible effect. It is evident that the vibration technique with optimize frequency and amplitude can reduce fouling rates in both organic and inorganic solutions. However, further understanding of fouling mechanism in organic solutions has to be studied for its full applicability in vibration membrane system. Bachelor of Engineering (Environmental Engineering) 2012-05-15T08:48:39Z 2012-05-15T08:48:39Z 2012 2012 Final Year Project (FYP) http://hdl.handle.net/10356/49189 en Nanyang Technological University 55 p. application/pdf
spellingShingle DRNTU::Engineering::Environmental engineering::Water treatment
Tan, Li Lian.
Vibration of membrane modules for low pressure membrane process
title Vibration of membrane modules for low pressure membrane process
title_full Vibration of membrane modules for low pressure membrane process
title_fullStr Vibration of membrane modules for low pressure membrane process
title_full_unstemmed Vibration of membrane modules for low pressure membrane process
title_short Vibration of membrane modules for low pressure membrane process
title_sort vibration of membrane modules for low pressure membrane process
topic DRNTU::Engineering::Environmental engineering::Water treatment
url http://hdl.handle.net/10356/49189
work_keys_str_mv AT tanlilian vibrationofmembranemodulesforlowpressuremembraneprocess