A comparison between cannulated and non-cannulated cancellous screws used in the fixation of a simulated femoral neck fracture

This project aims to create a three dimensional (3D) finite element model of a human femoral neck fracture fixed by stainless steel orthopedic screws. The screws used were either, cannulated and non-cannulated of varying outer diameters.

Bibliographic Details
Main Author: Muhammad Nizar Abdul Razak.
Other Authors: Chou Siaw Meng
Format: Final Year Project (FYP)
Language:English
Published: 2012
Subjects:
Online Access:http://hdl.handle.net/10356/50231
_version_ 1811694068595425280
author Muhammad Nizar Abdul Razak.
author2 Chou Siaw Meng
author_facet Chou Siaw Meng
Muhammad Nizar Abdul Razak.
author_sort Muhammad Nizar Abdul Razak.
collection NTU
description This project aims to create a three dimensional (3D) finite element model of a human femoral neck fracture fixed by stainless steel orthopedic screws. The screws used were either, cannulated and non-cannulated of varying outer diameters.
first_indexed 2024-10-01T07:01:42Z
format Final Year Project (FYP)
id ntu-10356/50231
institution Nanyang Technological University
language English
last_indexed 2024-10-01T07:01:42Z
publishDate 2012
record_format dspace
spelling ntu-10356/502312023-03-04T18:28:31Z A comparison between cannulated and non-cannulated cancellous screws used in the fixation of a simulated femoral neck fracture Muhammad Nizar Abdul Razak. Chou Siaw Meng School of Mechanical and Aerospace Engineering DRNTU::Engineering::Mechanical engineering This project aims to create a three dimensional (3D) finite element model of a human femoral neck fracture fixed by stainless steel orthopedic screws. The screws used were either, cannulated and non-cannulated of varying outer diameters. Bachelor of Engineering (Mechanical Engineering) 2012-05-31T03:24:34Z 2012-05-31T03:24:34Z 2012 2012 Final Year Project (FYP) http://hdl.handle.net/10356/50231 en Nanyang Technological University 90 p. application/pdf
spellingShingle DRNTU::Engineering::Mechanical engineering
Muhammad Nizar Abdul Razak.
A comparison between cannulated and non-cannulated cancellous screws used in the fixation of a simulated femoral neck fracture
title A comparison between cannulated and non-cannulated cancellous screws used in the fixation of a simulated femoral neck fracture
title_full A comparison between cannulated and non-cannulated cancellous screws used in the fixation of a simulated femoral neck fracture
title_fullStr A comparison between cannulated and non-cannulated cancellous screws used in the fixation of a simulated femoral neck fracture
title_full_unstemmed A comparison between cannulated and non-cannulated cancellous screws used in the fixation of a simulated femoral neck fracture
title_short A comparison between cannulated and non-cannulated cancellous screws used in the fixation of a simulated femoral neck fracture
title_sort comparison between cannulated and non cannulated cancellous screws used in the fixation of a simulated femoral neck fracture
topic DRNTU::Engineering::Mechanical engineering
url http://hdl.handle.net/10356/50231
work_keys_str_mv AT muhammadnizarabdulrazak acomparisonbetweencannulatedandnoncannulatedcancellousscrewsusedinthefixationofasimulatedfemoralneckfracture
AT muhammadnizarabdulrazak comparisonbetweencannulatedandnoncannulatedcancellousscrewsusedinthefixationofasimulatedfemoralneckfracture