Pushing the limits of relaxation and modulated-bath AC calorimetry.

The measurement of low temperature specific heat provides us a great amount of information on the lattice and electronic properties. Many different designs and techniques have developed so far to conduct the low temperature specific heat measurement. In this project, a new relaxation colorimeter is...

Full description

Bibliographic Details
Main Author: Song, Zhibo.
Other Authors: School of Physical and Mathematical Sciences
Format: Final Year Project (FYP)
Language:English
Published: 2013
Subjects:
Online Access:http://hdl.handle.net/10356/53679
_version_ 1824456561490132992
author Song, Zhibo.
author2 School of Physical and Mathematical Sciences
author_facet School of Physical and Mathematical Sciences
Song, Zhibo.
author_sort Song, Zhibo.
collection NTU
description The measurement of low temperature specific heat provides us a great amount of information on the lattice and electronic properties. Many different designs and techniques have developed so far to conduct the low temperature specific heat measurement. In this project, a new relaxation colorimeter is designed to operate at a temperature between 1.5K and 300K with magnetic field up to 16T. Then a modulated-bath AC calorimetry is incorporated with the relaxation calorimeter is a single setup for the purpose of measuring specific heat at a wider temperature spectrum and on smaller (micro-scale) sample scale. This design also has the advantage that the DC offset which plagues conventional AC calorimeter can be eliminated by superposing an AC plus DC current supply to the joule heater. The detailed design of this calorimeter is investigated and the full working principle is explained. The measuring process is modelling and simulating mainly using MATLAB and LabVIEW software. The simulation will be conducted using 3 milligram pure copper for the temperature range from 2K to 10K based on the modulated-bath AC method. Results of the simulation have shown a great reliability of the calorimeter that the error for specific heat measurement is less than 0.05% under the condition that the working frequency is carefully selected.
first_indexed 2025-02-19T03:56:04Z
format Final Year Project (FYP)
id ntu-10356/53679
institution Nanyang Technological University
language English
last_indexed 2025-02-19T03:56:04Z
publishDate 2013
record_format dspace
spelling ntu-10356/536792023-02-28T23:19:38Z Pushing the limits of relaxation and modulated-bath AC calorimetry. Song, Zhibo. School of Physical and Mathematical Sciences Panagopoulos Christos DRNTU::Science The measurement of low temperature specific heat provides us a great amount of information on the lattice and electronic properties. Many different designs and techniques have developed so far to conduct the low temperature specific heat measurement. In this project, a new relaxation colorimeter is designed to operate at a temperature between 1.5K and 300K with magnetic field up to 16T. Then a modulated-bath AC calorimetry is incorporated with the relaxation calorimeter is a single setup for the purpose of measuring specific heat at a wider temperature spectrum and on smaller (micro-scale) sample scale. This design also has the advantage that the DC offset which plagues conventional AC calorimeter can be eliminated by superposing an AC plus DC current supply to the joule heater. The detailed design of this calorimeter is investigated and the full working principle is explained. The measuring process is modelling and simulating mainly using MATLAB and LabVIEW software. The simulation will be conducted using 3 milligram pure copper for the temperature range from 2K to 10K based on the modulated-bath AC method. Results of the simulation have shown a great reliability of the calorimeter that the error for specific heat measurement is less than 0.05% under the condition that the working frequency is carefully selected. Bachelor of Science in Physics 2013-06-06T08:56:32Z 2013-06-06T08:56:32Z 2013 2013 Final Year Project (FYP) http://hdl.handle.net/10356/53679 en 79 p. application/pdf
spellingShingle DRNTU::Science
Song, Zhibo.
Pushing the limits of relaxation and modulated-bath AC calorimetry.
title Pushing the limits of relaxation and modulated-bath AC calorimetry.
title_full Pushing the limits of relaxation and modulated-bath AC calorimetry.
title_fullStr Pushing the limits of relaxation and modulated-bath AC calorimetry.
title_full_unstemmed Pushing the limits of relaxation and modulated-bath AC calorimetry.
title_short Pushing the limits of relaxation and modulated-bath AC calorimetry.
title_sort pushing the limits of relaxation and modulated bath ac calorimetry
topic DRNTU::Science
url http://hdl.handle.net/10356/53679
work_keys_str_mv AT songzhibo pushingthelimitsofrelaxationandmodulatedbathaccalorimetry