Study of mechanism of ultrasonic wire bonding process

In this study, a sensing cum actuating (SCA) technique is developed to study the wire bonding system. The actuating mechanism of a wire bonder is viewed as an SCA device which possesses an unique transduction matrix correlating the electrical input variables of the PZT driver and the mechanical outp...

Full description

Bibliographic Details
Main Author: Zhang, Dong
Other Authors: Ling, Shih Fu
Format: Thesis
Published: 2008
Subjects:
Online Access:http://hdl.handle.net/10356/5516
Description
Summary:In this study, a sensing cum actuating (SCA) technique is developed to study the wire bonding system. The actuating mechanism of a wire bonder is viewed as an SCA device which possesses an unique transduction matrix correlating the electrical input variables of the PZT driver and the mechanical output variables at the tip of the capillary. The transduction matrix is identified experimentally. Thus, the force and velocity at the tip of the capillary is first time obtained from the input voltage and current of the PZT driver.