Enhancement of microwave power sensor measurement with adaptors

Calibration is important in microwave power sensor measurement, since it can improve the overall accuracy of the measurement. A calibration factor is used as a correction factor; it describes both the effective efficiency and reflection coefficient of the power sensor. Generally, the calibration fa...

Full description

Bibliographic Details
Main Author: Qiu, Tie
Other Authors: Lin Zhiping
Format: Final Year Project (FYP)
Language:English
Published: 2014
Subjects:
Online Access:http://hdl.handle.net/10356/60425
_version_ 1811691327437406208
author Qiu, Tie
author2 Lin Zhiping
author_facet Lin Zhiping
Qiu, Tie
author_sort Qiu, Tie
collection NTU
description Calibration is important in microwave power sensor measurement, since it can improve the overall accuracy of the measurement. A calibration factor is used as a correction factor; it describes both the effective efficiency and reflection coefficient of the power sensor. Generally, the calibration factor will be used in the calibration transfer from a reference standard to the device under test. And the direct comparison transfer technique is the simplest and most evident method to achieve the calibration of power sensors by using calibration transfer. Nowadays, for further developments of the direct comparison technique, different adaptors (attenuators) could be used in some implementations. Therefore, their effects should be investigated since they can introduce additional measurement uncertainties. In this report, the effects of different adaptors on microwave power sensor calibration with direct comparison technique have been studied. And the calibrations are implemented with a mathematical model proposed by NMC recently. To verify its accuracy in calculating the calibration factor, a comparison is carried out between the mathematical model proposed by NMC and other research. The comparison indicates that the equation derived in the model is accurate to calculate the calibration factor of microwave power sensors. For its implementations, a 0 dB adaptor, 10 dB, 20 dB and 30 dB attenuators are used to evaluate the effects from different adaptors. Results show that when the attenuation of an adaptor increases, the expanded uncertainty of the calibration factor increases correspondingly, following the Guide to the Expression of Uncertainty in Measurement (GUM). Moreover, to verify the uncertainty results of GUM, the Monte Carlo Method is used to simulate the expanded uncertainty of the calibration factor as well. On the other hand, for the enhancement of the existing software used to execute the calculation and simulation in calibrations, a new software is developed based on the LABVIEW programming software. In addition, comparisons are made between the calculation and simulation results of the new and previous software in order to check the accuracy.
first_indexed 2024-10-01T06:18:08Z
format Final Year Project (FYP)
id ntu-10356/60425
institution Nanyang Technological University
language English
last_indexed 2024-10-01T06:18:08Z
publishDate 2014
record_format dspace
spelling ntu-10356/604252023-07-07T16:43:51Z Enhancement of microwave power sensor measurement with adaptors Qiu, Tie Lin Zhiping School of Electrical and Electronic Engineering A*STAR National Metrology Centre DRNTU::Engineering::Electrical and electronic engineering::Antennas, wave guides, microwaves, radar, radio Calibration is important in microwave power sensor measurement, since it can improve the overall accuracy of the measurement. A calibration factor is used as a correction factor; it describes both the effective efficiency and reflection coefficient of the power sensor. Generally, the calibration factor will be used in the calibration transfer from a reference standard to the device under test. And the direct comparison transfer technique is the simplest and most evident method to achieve the calibration of power sensors by using calibration transfer. Nowadays, for further developments of the direct comparison technique, different adaptors (attenuators) could be used in some implementations. Therefore, their effects should be investigated since they can introduce additional measurement uncertainties. In this report, the effects of different adaptors on microwave power sensor calibration with direct comparison technique have been studied. And the calibrations are implemented with a mathematical model proposed by NMC recently. To verify its accuracy in calculating the calibration factor, a comparison is carried out between the mathematical model proposed by NMC and other research. The comparison indicates that the equation derived in the model is accurate to calculate the calibration factor of microwave power sensors. For its implementations, a 0 dB adaptor, 10 dB, 20 dB and 30 dB attenuators are used to evaluate the effects from different adaptors. Results show that when the attenuation of an adaptor increases, the expanded uncertainty of the calibration factor increases correspondingly, following the Guide to the Expression of Uncertainty in Measurement (GUM). Moreover, to verify the uncertainty results of GUM, the Monte Carlo Method is used to simulate the expanded uncertainty of the calibration factor as well. On the other hand, for the enhancement of the existing software used to execute the calculation and simulation in calibrations, a new software is developed based on the LABVIEW programming software. In addition, comparisons are made between the calculation and simulation results of the new and previous software in order to check the accuracy. Bachelor of Engineering 2014-05-27T04:39:23Z 2014-05-27T04:39:23Z 2014 2014 Final Year Project (FYP) http://hdl.handle.net/10356/60425 en Nanyang Technological University 83 p. application/pdf
spellingShingle DRNTU::Engineering::Electrical and electronic engineering::Antennas, wave guides, microwaves, radar, radio
Qiu, Tie
Enhancement of microwave power sensor measurement with adaptors
title Enhancement of microwave power sensor measurement with adaptors
title_full Enhancement of microwave power sensor measurement with adaptors
title_fullStr Enhancement of microwave power sensor measurement with adaptors
title_full_unstemmed Enhancement of microwave power sensor measurement with adaptors
title_short Enhancement of microwave power sensor measurement with adaptors
title_sort enhancement of microwave power sensor measurement with adaptors
topic DRNTU::Engineering::Electrical and electronic engineering::Antennas, wave guides, microwaves, radar, radio
url http://hdl.handle.net/10356/60425
work_keys_str_mv AT qiutie enhancementofmicrowavepowersensormeasurementwithadaptors