In this report the author expressed his understanding of Eurocode 7 and the Load and Resistance Factor Design, in the designing for retaining structure, specifically the design for gravity retaining wall. The basis of geotechnical engineering will be discussed in this report; various earth pressure...

Full description

Bibliographic Details
Main Author: Chua, Jackson Jian Shen
Other Authors: Low Bak Kong
Format: Final Year Project (FYP)
Language:English
Published: 2014
Subjects:
Online Access:http://hdl.handle.net/10356/60668
_version_ 1826121808740352000
author Chua, Jackson Jian Shen
author2 Low Bak Kong
author_facet Low Bak Kong
Chua, Jackson Jian Shen
author_sort Chua, Jackson Jian Shen
collection NTU
description In this report the author expressed his understanding of Eurocode 7 and the Load and Resistance Factor Design, in the designing for retaining structure, specifically the design for gravity retaining wall. The basis of geotechnical engineering will be discussed in this report; various earth pressure derivation and common bearing capacity of substructure were also mentioned.
first_indexed 2024-10-01T05:38:34Z
format Final Year Project (FYP)
id ntu-10356/60668
institution Nanyang Technological University
language English
last_indexed 2024-10-01T05:38:34Z
publishDate 2014
record_format dspace
spelling ntu-10356/606682023-03-03T17:09:16Z Comparative study of Eurocode 7 design and load and resistance factor design in geotechnical engineering (retaining wall) Chua, Jackson Jian Shen Low Bak Kong School of Civil and Environmental Engineering DRNTU::Engineering::Civil engineering In this report the author expressed his understanding of Eurocode 7 and the Load and Resistance Factor Design, in the designing for retaining structure, specifically the design for gravity retaining wall. The basis of geotechnical engineering will be discussed in this report; various earth pressure derivation and common bearing capacity of substructure were also mentioned. Bachelor of Engineering (Civil) 2014-05-29T05:16:35Z 2014-05-29T05:16:35Z 2014 2014 Final Year Project (FYP) http://hdl.handle.net/10356/60668 en Nanyang Technological University 63 p. application/pdf
spellingShingle DRNTU::Engineering::Civil engineering
Chua, Jackson Jian Shen
Comparative study of Eurocode 7 design and load and resistance factor design in geotechnical engineering (retaining wall)
title Comparative study of Eurocode 7 design and load and resistance factor design in geotechnical engineering (retaining wall)
title_full Comparative study of Eurocode 7 design and load and resistance factor design in geotechnical engineering (retaining wall)
title_fullStr Comparative study of Eurocode 7 design and load and resistance factor design in geotechnical engineering (retaining wall)
title_full_unstemmed Comparative study of Eurocode 7 design and load and resistance factor design in geotechnical engineering (retaining wall)
title_short Comparative study of Eurocode 7 design and load and resistance factor design in geotechnical engineering (retaining wall)
title_sort comparative study of eurocode 7 design and load and resistance factor design in geotechnical engineering retaining wall
topic DRNTU::Engineering::Civil engineering
url http://hdl.handle.net/10356/60668
work_keys_str_mv AT chuajacksonjianshen comparativestudyofeurocode7designandloadandresistancefactordesigningeotechnicalengineeringretainingwall