Transdermal Drug Delivery

Sonophoresis is the use of ultrasound to transport medicinal agents through the skin. With sonophoresis, absorption of drugs into the skin is exponentially increases. Due to the ultrasound waves, the skin is stimulated by micro-vibrations, escalating the overall kinetic energy of formulating molecul...

Full description

Bibliographic Details
Main Author: Tan, Zi Hui
Other Authors: School of Mechanical and Aerospace Engineering
Format: Final Year Project (FYP)
Language:English
Published: 2014
Subjects:
Online Access:http://hdl.handle.net/10356/61301
_version_ 1811678899809026048
author Tan, Zi Hui
author2 School of Mechanical and Aerospace Engineering
author_facet School of Mechanical and Aerospace Engineering
Tan, Zi Hui
author_sort Tan, Zi Hui
collection NTU
description Sonophoresis is the use of ultrasound to transport medicinal agents through the skin. With sonophoresis, absorption of drugs into the skin is exponentially increases. Due to the ultrasound waves, the skin is stimulated by micro-vibrations, escalating the overall kinetic energy of formulating molecules of these agents. During sonophoresis, holes are created in the skin allowing fluid to enter the human body – acoustic waves disturb the lipid bilayers. With the use of ultrasound, drug delivery is improved by cavitation, microstreaming, and heating. For this study, the main objective is to understand the influence of frequency of ultrasound used on Transdermal Drug Delivery (TDD) systems and damage to the skin. Principally, an increase in skin permeability should not be in the expense of permanent damage to the skin. In the study, two ultrasound transducers of frequencies 200kHz and 1MHz respectively was fabricated and calibrated. To study the effects of frequency of ultrasound on effectiveness of fluorescent nanoparticles penetration through porcine ear skin, microplate readings of fluorescent intensity before and after sonication were obtained. Subsequently, Scanning Electron Microscope (SEM) imaging of porcine samples were also taken for visualization of possible damages made to the skin. To isolate the effects of varying frequency in TDD systems, 60nm fluorescent nanoparticles was used at a fixed intensity of 1.5W/cm2, with sonication exposure time of 15 minutes. For better appreciation of results, a list of topics was reviewed – benefits and limitations of TDD systems, sonophoresis and effects of frequency on its efficacy, piezoelectric effects and efficiency of a matching network box. Overall results was analysed and compared, and it was found that the lower frequency transducer (200kHz) causes more biological effects, while the higher frequency transducer (1MHz) has higher efficacy in drug penetration.
first_indexed 2024-10-01T03:00:36Z
format Final Year Project (FYP)
id ntu-10356/61301
institution Nanyang Technological University
language English
last_indexed 2024-10-01T03:00:36Z
publishDate 2014
record_format dspace
spelling ntu-10356/613012023-03-04T18:18:50Z Transdermal Drug Delivery Tan, Zi Hui School of Mechanical and Aerospace Engineering Ast/P Zhou Yufeng DRNTU::Engineering::Mechanical engineering Sonophoresis is the use of ultrasound to transport medicinal agents through the skin. With sonophoresis, absorption of drugs into the skin is exponentially increases. Due to the ultrasound waves, the skin is stimulated by micro-vibrations, escalating the overall kinetic energy of formulating molecules of these agents. During sonophoresis, holes are created in the skin allowing fluid to enter the human body – acoustic waves disturb the lipid bilayers. With the use of ultrasound, drug delivery is improved by cavitation, microstreaming, and heating. For this study, the main objective is to understand the influence of frequency of ultrasound used on Transdermal Drug Delivery (TDD) systems and damage to the skin. Principally, an increase in skin permeability should not be in the expense of permanent damage to the skin. In the study, two ultrasound transducers of frequencies 200kHz and 1MHz respectively was fabricated and calibrated. To study the effects of frequency of ultrasound on effectiveness of fluorescent nanoparticles penetration through porcine ear skin, microplate readings of fluorescent intensity before and after sonication were obtained. Subsequently, Scanning Electron Microscope (SEM) imaging of porcine samples were also taken for visualization of possible damages made to the skin. To isolate the effects of varying frequency in TDD systems, 60nm fluorescent nanoparticles was used at a fixed intensity of 1.5W/cm2, with sonication exposure time of 15 minutes. For better appreciation of results, a list of topics was reviewed – benefits and limitations of TDD systems, sonophoresis and effects of frequency on its efficacy, piezoelectric effects and efficiency of a matching network box. Overall results was analysed and compared, and it was found that the lower frequency transducer (200kHz) causes more biological effects, while the higher frequency transducer (1MHz) has higher efficacy in drug penetration. Bachelor of Engineering (Mechanical Engineering) 2014-06-09T03:09:58Z 2014-06-09T03:09:58Z 2014 2014 Final Year Project (FYP) http://hdl.handle.net/10356/61301 en Nanyang Technological University 82 p. application/pdf
spellingShingle DRNTU::Engineering::Mechanical engineering
Tan, Zi Hui
Transdermal Drug Delivery
title Transdermal Drug Delivery
title_full Transdermal Drug Delivery
title_fullStr Transdermal Drug Delivery
title_full_unstemmed Transdermal Drug Delivery
title_short Transdermal Drug Delivery
title_sort transdermal drug delivery
topic DRNTU::Engineering::Mechanical engineering
url http://hdl.handle.net/10356/61301
work_keys_str_mv AT tanzihui transdermaldrugdelivery