Water flow control for optimal operation of air to water heat exchanger

Chilled beam systems are considered to be energy efficient and have the ability to provide sensible cooling in a given space. Active chilled beam systems (ACB) will be the primary focus over the passive system due to the higher cooling efficiency. ACB consists of chilled water pipes and an integral...

Full description

Bibliographic Details
Main Author: Muhammad Nurul Irfan Abdul Aziz
Other Authors: Cai Wenjian
Format: Final Year Project (FYP)
Language:English
Published: 2014
Subjects:
Online Access:http://hdl.handle.net/10356/61450
_version_ 1811697525083602944
author Muhammad Nurul Irfan Abdul Aziz
author2 Cai Wenjian
author_facet Cai Wenjian
Muhammad Nurul Irfan Abdul Aziz
author_sort Muhammad Nurul Irfan Abdul Aziz
collection NTU
description Chilled beam systems are considered to be energy efficient and have the ability to provide sensible cooling in a given space. Active chilled beam systems (ACB) will be the primary focus over the passive system due to the higher cooling efficiency. ACB consists of chilled water pipes and an integral air supply unit. This is to create force induction of air in the room and the reconditioned air will be cooled again upon mixing with the primary air. Consideration of the flow and temperature of the chilled water has to be taken into account so as to prevent condensation from occurring. Focusing on the water side ACB system, to achieve a certain desired temperature in the room and prevent condensation from occurring, the flow of water in the chilled pipe has to be regulated. This is achieved by controlling the modulating valve and pump. Thus, by understanding the valve and pump characteristics and identifying the open loop process of the equipments will enable us to create a closed loop discrete PID controller which will allow the user to control and set the flow of water in the chilled pipes. Computational, simulation and interfacing of the system processes and hardware will be aided by the use of Labview and Matlab software. The presence of the PID controller and filter in the system results in a smooth, non-overshoot and fast response output. It does not only respond quickly to the change in flow set point however it eliminates unnecessary oscillations in the output response curve. Thorough study on the output response curve of the equipment not only exhibits the behavior of equipment given any conditions but allows further tuning and improvising of system.
first_indexed 2024-10-01T07:56:38Z
format Final Year Project (FYP)
id ntu-10356/61450
institution Nanyang Technological University
language English
last_indexed 2024-10-01T07:56:38Z
publishDate 2014
record_format dspace
spelling ntu-10356/614502023-07-07T16:05:29Z Water flow control for optimal operation of air to water heat exchanger Muhammad Nurul Irfan Abdul Aziz Cai Wenjian School of Electrical and Electronic Engineering DRNTU::Engineering::Electrical and electronic engineering::Control and instrumentation::Control engineering Chilled beam systems are considered to be energy efficient and have the ability to provide sensible cooling in a given space. Active chilled beam systems (ACB) will be the primary focus over the passive system due to the higher cooling efficiency. ACB consists of chilled water pipes and an integral air supply unit. This is to create force induction of air in the room and the reconditioned air will be cooled again upon mixing with the primary air. Consideration of the flow and temperature of the chilled water has to be taken into account so as to prevent condensation from occurring. Focusing on the water side ACB system, to achieve a certain desired temperature in the room and prevent condensation from occurring, the flow of water in the chilled pipe has to be regulated. This is achieved by controlling the modulating valve and pump. Thus, by understanding the valve and pump characteristics and identifying the open loop process of the equipments will enable us to create a closed loop discrete PID controller which will allow the user to control and set the flow of water in the chilled pipes. Computational, simulation and interfacing of the system processes and hardware will be aided by the use of Labview and Matlab software. The presence of the PID controller and filter in the system results in a smooth, non-overshoot and fast response output. It does not only respond quickly to the change in flow set point however it eliminates unnecessary oscillations in the output response curve. Thorough study on the output response curve of the equipment not only exhibits the behavior of equipment given any conditions but allows further tuning and improvising of system. Bachelor of Engineering 2014-06-10T06:39:34Z 2014-06-10T06:39:34Z 2014 2014 Final Year Project (FYP) http://hdl.handle.net/10356/61450 en Nanyang Technological University 74 p. application/pdf
spellingShingle DRNTU::Engineering::Electrical and electronic engineering::Control and instrumentation::Control engineering
Muhammad Nurul Irfan Abdul Aziz
Water flow control for optimal operation of air to water heat exchanger
title Water flow control for optimal operation of air to water heat exchanger
title_full Water flow control for optimal operation of air to water heat exchanger
title_fullStr Water flow control for optimal operation of air to water heat exchanger
title_full_unstemmed Water flow control for optimal operation of air to water heat exchanger
title_short Water flow control for optimal operation of air to water heat exchanger
title_sort water flow control for optimal operation of air to water heat exchanger
topic DRNTU::Engineering::Electrical and electronic engineering::Control and instrumentation::Control engineering
url http://hdl.handle.net/10356/61450
work_keys_str_mv AT muhammadnurulirfanabdulaziz waterflowcontrolforoptimaloperationofairtowaterheatexchanger