Retractable syringes

A needlestick injury may pose a high risk of bloodstream infections for anyone if the needle carries HBV, HCV or HIV. Some safety syringe has been patented and been used in some clinics of American and other developed countries to reduce the chance of needlestick. The safety syringes are required to...

Full description

Bibliographic Details
Main Author: Yi, Lei
Other Authors: Zhou Yu Feng
Format: Final Year Project (FYP)
Language:English
Published: 2015
Subjects:
Online Access:http://hdl.handle.net/10356/63455
_version_ 1826121234526502912
author Yi, Lei
author2 Zhou Yu Feng
author_facet Zhou Yu Feng
Yi, Lei
author_sort Yi, Lei
collection NTU
description A needlestick injury may pose a high risk of bloodstream infections for anyone if the needle carries HBV, HCV or HIV. Some safety syringe has been patented and been used in some clinics of American and other developed countries to reduce the chance of needlestick. The safety syringes are required to be further developed to make its safety feature more integral and friendly to the users. The student is required to study the design criteria based on the model in Patent US 7476215 B2. Dimensionless analysis are used to satisfy the general syringes with different dimensions. Experiments of different perimeter with different sizes are carried in MATLAB language program. From the results of the experiments, the student can predict the basic trend of the design perimeter, which are pressure, length and mass. Inside pressure and remaining length of the simulated cylinder can be affected by different area, different friction and different mass to be retracted: the inside pressure will increase with less time by increasing the area of the plate, by decreasing the friction between the plunger and the vacuum plunger seal and by decreasing the total retracted mass; the longer retracted length can be achieved by enlarging the plate diameter, by decreasing the friction between the plunger and the vacuum plunger seal and by decreasing the total retracted mass. A simulation based on the results of experiment is made to express the whole retracted process more clearly and visually.
first_indexed 2024-10-01T05:29:03Z
format Final Year Project (FYP)
id ntu-10356/63455
institution Nanyang Technological University
language English
last_indexed 2024-10-01T05:29:03Z
publishDate 2015
record_format dspace
spelling ntu-10356/634552023-03-04T18:47:54Z Retractable syringes Yi, Lei Zhou Yu Feng School of Mechanical and Aerospace Engineering DRNTU::Engineering::Mechanical engineering A needlestick injury may pose a high risk of bloodstream infections for anyone if the needle carries HBV, HCV or HIV. Some safety syringe has been patented and been used in some clinics of American and other developed countries to reduce the chance of needlestick. The safety syringes are required to be further developed to make its safety feature more integral and friendly to the users. The student is required to study the design criteria based on the model in Patent US 7476215 B2. Dimensionless analysis are used to satisfy the general syringes with different dimensions. Experiments of different perimeter with different sizes are carried in MATLAB language program. From the results of the experiments, the student can predict the basic trend of the design perimeter, which are pressure, length and mass. Inside pressure and remaining length of the simulated cylinder can be affected by different area, different friction and different mass to be retracted: the inside pressure will increase with less time by increasing the area of the plate, by decreasing the friction between the plunger and the vacuum plunger seal and by decreasing the total retracted mass; the longer retracted length can be achieved by enlarging the plate diameter, by decreasing the friction between the plunger and the vacuum plunger seal and by decreasing the total retracted mass. A simulation based on the results of experiment is made to express the whole retracted process more clearly and visually. Bachelor of Engineering (Mechanical Engineering) 2015-05-13T09:23:37Z 2015-05-13T09:23:37Z 2015 2015 Final Year Project (FYP) http://hdl.handle.net/10356/63455 en Nanyang Technological University 79 p. application/pdf application/octet-stream
spellingShingle DRNTU::Engineering::Mechanical engineering
Yi, Lei
Retractable syringes
title Retractable syringes
title_full Retractable syringes
title_fullStr Retractable syringes
title_full_unstemmed Retractable syringes
title_short Retractable syringes
title_sort retractable syringes
topic DRNTU::Engineering::Mechanical engineering
url http://hdl.handle.net/10356/63455
work_keys_str_mv AT yilei retractablesyringes