Air flow measurement and sensor calibration in air duct

This report presents a measurement study on the airflow measurement technique with Pitot Tube customised by NTU in comparison with the commercially available Pitot Tubes. The major testing was done based on the testing bed simulated in the laboratory. An airflow testing bed that consists of a vor...

Full description

Bibliographic Details
Main Author: Low, Emily Ying Ting
Other Authors: Cai Wenjian
Format: Final Year Project (FYP)
Language:English
Published: 2016
Subjects:
Online Access:http://hdl.handle.net/10356/69324
_version_ 1811690844696084480
author Low, Emily Ying Ting
author2 Cai Wenjian
author_facet Cai Wenjian
Low, Emily Ying Ting
author_sort Low, Emily Ying Ting
collection NTU
description This report presents a measurement study on the airflow measurement technique with Pitot Tube customised by NTU in comparison with the commercially available Pitot Tubes. The major testing was done based on the testing bed simulated in the laboratory. An airflow testing bed that consists of a vortex flow meter pressure difference sensor, a centrifugal fan, air ducts, a damper and a calibrator was the chosen simulation set up in which the measurements was taken. Each damper angle was measured and adjusted accordingly at intervals during the measurement controlling the effects of pressure difference flowing into the pressure sensor. Air flow rate was controlled by adjusting the voltages of supplied to the centrifugal fan, where the air generated will then flow through the air ducts and into an air pressure sensor (Pitot Tube) where the differential pressures were measured. The collected measurements were later used In calculations to determine the accuracy of the measuring sensor device (Pitot Tube). The accuracy of the sensor was determined after rounds of calculations determining and considering the variance and changes in pressure as well as the variance in angles of the damper blades was taken into consideration when the test was performed. Future work would be required to further reaffirm the efficiency and effectiveness as well as the possibility of implementing the current design of the sensor commercially.
first_indexed 2024-10-01T06:10:27Z
format Final Year Project (FYP)
id ntu-10356/69324
institution Nanyang Technological University
language English
last_indexed 2024-10-01T06:10:27Z
publishDate 2016
record_format dspace
spelling ntu-10356/693242023-07-07T17:39:11Z Air flow measurement and sensor calibration in air duct Low, Emily Ying Ting Cai Wenjian School of Electrical and Electronic Engineering DRNTU::Engineering This report presents a measurement study on the airflow measurement technique with Pitot Tube customised by NTU in comparison with the commercially available Pitot Tubes. The major testing was done based on the testing bed simulated in the laboratory. An airflow testing bed that consists of a vortex flow meter pressure difference sensor, a centrifugal fan, air ducts, a damper and a calibrator was the chosen simulation set up in which the measurements was taken. Each damper angle was measured and adjusted accordingly at intervals during the measurement controlling the effects of pressure difference flowing into the pressure sensor. Air flow rate was controlled by adjusting the voltages of supplied to the centrifugal fan, where the air generated will then flow through the air ducts and into an air pressure sensor (Pitot Tube) where the differential pressures were measured. The collected measurements were later used In calculations to determine the accuracy of the measuring sensor device (Pitot Tube). The accuracy of the sensor was determined after rounds of calculations determining and considering the variance and changes in pressure as well as the variance in angles of the damper blades was taken into consideration when the test was performed. Future work would be required to further reaffirm the efficiency and effectiveness as well as the possibility of implementing the current design of the sensor commercially. Bachelor of Engineering 2016-12-13T08:22:44Z 2016-12-13T08:22:44Z 2016 Final Year Project (FYP) http://hdl.handle.net/10356/69324 en Nanyang Technological University 60 p. application/pdf
spellingShingle DRNTU::Engineering
Low, Emily Ying Ting
Air flow measurement and sensor calibration in air duct
title Air flow measurement and sensor calibration in air duct
title_full Air flow measurement and sensor calibration in air duct
title_fullStr Air flow measurement and sensor calibration in air duct
title_full_unstemmed Air flow measurement and sensor calibration in air duct
title_short Air flow measurement and sensor calibration in air duct
title_sort air flow measurement and sensor calibration in air duct
topic DRNTU::Engineering
url http://hdl.handle.net/10356/69324
work_keys_str_mv AT lowemilyyingting airflowmeasurementandsensorcalibrationinairduct