With the world going digital, communication system has become more important. With the upcoming trend of internet of things, digital equipment is now communicating with one another through various means. The most traditional method is through communication between copper wires for example the RS232....

Full description

Bibliographic Details
Main Author: Wong, Guo Yao
Other Authors: Wang Peng
Format: Final Year Project (FYP)
Language:English
Published: 2017
Subjects:
Online Access:http://hdl.handle.net/10356/71104
_version_ 1811677655873880064
author Wong, Guo Yao
author2 Wang Peng
author_facet Wang Peng
Wong, Guo Yao
author_sort Wong, Guo Yao
collection NTU
description With the world going digital, communication system has become more important. With the upcoming trend of internet of things, digital equipment is now communicating with one another through various means. The most traditional method is through communication between copper wires for example the RS232. Although this method of transmission has been around for many years, the fundamental principle behind it is important as it pave the way for more complex communication form such as the Ethernet. Using a structured protocol, the communication system can be broken into many layers where each level can interact with layers above and below it. This is done to minimize the disturbance to the system when one component changes. The design of the frame/ packet in which the data will be formatted into is also very important. Careful considerations must be noted to ensure that sufficient information of the data is encoded into the frame and the length of the packet must be kept at the minimum to ensure a higher transmission performance of the data. GUI is an effective method for users to input data which will be converted into machine language. Packets are formed with the help of the GUI, to make the transmitted data as accurate as possible. Information regarding the data, such as the start byte and the check sum, will be append to the packet. The packet will be transmitted across the communication channel and received by the receiver. The receiver will interpret the packet and process the relevant data using the information from the packet. The communication protocol that is designed and used in this report is to allow monitoring for the CHB medium voltage converter. This is essential to allow changes to be made for certain specification to the cells in the converter, at the same time retrieve reading from the cell to be displayed onto the GUI. Hence this project needs to take note on the reliability of communication system.
first_indexed 2024-10-01T02:40:49Z
format Final Year Project (FYP)
id ntu-10356/71104
institution Nanyang Technological University
language English
last_indexed 2024-10-01T02:40:49Z
publishDate 2017
record_format dspace
spelling ntu-10356/711042023-07-07T16:35:06Z Supervisory control for converter system Wong, Guo Yao Wang Peng School of Electrical and Electronic Engineering Rolls-Royce Singapore Pte. Ltd. DRNTU::Engineering::Electrical and electronic engineering With the world going digital, communication system has become more important. With the upcoming trend of internet of things, digital equipment is now communicating with one another through various means. The most traditional method is through communication between copper wires for example the RS232. Although this method of transmission has been around for many years, the fundamental principle behind it is important as it pave the way for more complex communication form such as the Ethernet. Using a structured protocol, the communication system can be broken into many layers where each level can interact with layers above and below it. This is done to minimize the disturbance to the system when one component changes. The design of the frame/ packet in which the data will be formatted into is also very important. Careful considerations must be noted to ensure that sufficient information of the data is encoded into the frame and the length of the packet must be kept at the minimum to ensure a higher transmission performance of the data. GUI is an effective method for users to input data which will be converted into machine language. Packets are formed with the help of the GUI, to make the transmitted data as accurate as possible. Information regarding the data, such as the start byte and the check sum, will be append to the packet. The packet will be transmitted across the communication channel and received by the receiver. The receiver will interpret the packet and process the relevant data using the information from the packet. The communication protocol that is designed and used in this report is to allow monitoring for the CHB medium voltage converter. This is essential to allow changes to be made for certain specification to the cells in the converter, at the same time retrieve reading from the cell to be displayed onto the GUI. Hence this project needs to take note on the reliability of communication system. Bachelor of Engineering 2017-05-15T04:43:12Z 2017-05-15T04:43:12Z 2017 Final Year Project (FYP) http://hdl.handle.net/10356/71104 en Nanyang Technological University 125 p. application/pdf
spellingShingle DRNTU::Engineering::Electrical and electronic engineering
Wong, Guo Yao
Supervisory control for converter system
title Supervisory control for converter system
title_full Supervisory control for converter system
title_fullStr Supervisory control for converter system
title_full_unstemmed Supervisory control for converter system
title_short Supervisory control for converter system
title_sort supervisory control for converter system
topic DRNTU::Engineering::Electrical and electronic engineering
url http://hdl.handle.net/10356/71104
work_keys_str_mv AT wongguoyao supervisorycontrolforconvertersystem