Part I: Development of sample preparation method for analysis of total iodine in air filters. Part II: Application of Inductively coupled plasma-mass spectrometry in analysis of radionuclides-uranium and plutonium

In Chapter one, an acid assisted closed vessel microwave digestion procedure was developed for the treatment of fine airborne particulate matter that allows elemental iodine to be solubilised simultaneously with metallic elements. This procedure is an improvement over existing methods as it allows t...

Full description

Bibliographic Details
Main Author: Tiong, Diane Ling Ying
Other Authors: Richard D. Webster
Format: Thesis
Language:English
Published: 2018
Subjects:
Online Access:http://hdl.handle.net/10356/73454
_version_ 1811692321919467520
author Tiong, Diane Ling Ying
author2 Richard D. Webster
author_facet Richard D. Webster
Tiong, Diane Ling Ying
author_sort Tiong, Diane Ling Ying
collection NTU
description In Chapter one, an acid assisted closed vessel microwave digestion procedure was developed for the treatment of fine airborne particulate matter that allows elemental iodine to be solubilised simultaneously with metallic elements. This procedure is an improvement over existing methods as it allows the iodine to be safely digested from the filter media (polypropylene or cellulose) in less than one hour and achieve up to 70–100 % recoveries, without requiring an overnight pre-digestion step or the addition of reducing agents, with a microwave temperature of 185 °C and the use of 65 % HNO3 in the digestion media. A range of filters were investigated to determine the material that has the best properties for microwave digestion that also enabled the deposited iodine present in total suspended particles (TSP) to be rapidly fully digested and quantitatively analysed using inductively coupled plasma-mass spectrometry (ICP-MS). This developed method has shown to be possible in the analysis of metallic elements with iodine of interest without the need of a separate chemical preparation steps. The following Chapters 3 and 4 are based on the analysis of radioactive isotopes of uranium and plutonium with the use of a quadrupole ICP-MS with a general introduction on radionuclide analysis in Chapter 2. Unlike other mass-spectrometric methods (eg,, Sector-field ICP-MS or Multi-collector ICP-MS), the quadrupole ICP-MS is a cost-effective (easier maintenance) analytical instrument with good sensitivity to sub-ppb levels In Chapter 3, plutonium analysis, in particular 238Pu, was performed with a non-radiometric method. 238Pu is an alpha emitter and hence can be analysed successfully with alpha spectrometry, which does not have any spectral interference although it is a very slow alpha emitter and requires a relatively long counting time. However, mass spectrometric analysis of 238Pu faces isobaric interference with interfering 238U which cannot be resolved. Therefore, in this chapter, a mass spectrometric method that uses an experimentally derived algebraic correction factor was developed that requires sample pretreatment with TEVA and UTEVA resin cartridges to separate the plutonium (TEVA) and uranium (UTEVA) in the sample. The proposed developed method was shown to be more effective when enriched uranium (weapon grade) was added into the sample prior to the resin-based separation steps. In chapter 4, analysis of uranium isotope samples has usually been performed in a clean-room facility due to the presence of natural uranium in the environment that can potentially contaminate the sample. However, a clean room facility is not available in many laboratories that also carry out ICP analysis. There is also a lack in understanding of the potential contributors to natural uranium contamination, which can be identified through analysis of the process blanks. In this study, the process blanks were analysed in parallel to all samples to enable blank corrections to be performed for every step of the sample treatment processes. A significant portion of the natural uranium contamination was found to derive from reagents and consumables. The capability of analysis of different enrichment levels of uranium samples were evaluated by varying the amount of samples spiked during the sample preparation technique (lithium borate fusion) and assessed with the related relative uncertainties at the various mass point of spiked samples. The thesis ends with a concluding Chapter 5.
first_indexed 2024-10-01T06:33:56Z
format Thesis
id ntu-10356/73454
institution Nanyang Technological University
language English
last_indexed 2024-10-01T06:33:56Z
publishDate 2018
record_format dspace
spelling ntu-10356/734542023-02-28T23:50:57Z Part I: Development of sample preparation method for analysis of total iodine in air filters. Part II: Application of Inductively coupled plasma-mass spectrometry in analysis of radionuclides-uranium and plutonium Tiong, Diane Ling Ying Richard D. Webster School of Physical and Mathematical Sciences DSO National Laboratories DRNTU::Science::Chemistry In Chapter one, an acid assisted closed vessel microwave digestion procedure was developed for the treatment of fine airborne particulate matter that allows elemental iodine to be solubilised simultaneously with metallic elements. This procedure is an improvement over existing methods as it allows the iodine to be safely digested from the filter media (polypropylene or cellulose) in less than one hour and achieve up to 70–100 % recoveries, without requiring an overnight pre-digestion step or the addition of reducing agents, with a microwave temperature of 185 °C and the use of 65 % HNO3 in the digestion media. A range of filters were investigated to determine the material that has the best properties for microwave digestion that also enabled the deposited iodine present in total suspended particles (TSP) to be rapidly fully digested and quantitatively analysed using inductively coupled plasma-mass spectrometry (ICP-MS). This developed method has shown to be possible in the analysis of metallic elements with iodine of interest without the need of a separate chemical preparation steps. The following Chapters 3 and 4 are based on the analysis of radioactive isotopes of uranium and plutonium with the use of a quadrupole ICP-MS with a general introduction on radionuclide analysis in Chapter 2. Unlike other mass-spectrometric methods (eg,, Sector-field ICP-MS or Multi-collector ICP-MS), the quadrupole ICP-MS is a cost-effective (easier maintenance) analytical instrument with good sensitivity to sub-ppb levels In Chapter 3, plutonium analysis, in particular 238Pu, was performed with a non-radiometric method. 238Pu is an alpha emitter and hence can be analysed successfully with alpha spectrometry, which does not have any spectral interference although it is a very slow alpha emitter and requires a relatively long counting time. However, mass spectrometric analysis of 238Pu faces isobaric interference with interfering 238U which cannot be resolved. Therefore, in this chapter, a mass spectrometric method that uses an experimentally derived algebraic correction factor was developed that requires sample pretreatment with TEVA and UTEVA resin cartridges to separate the plutonium (TEVA) and uranium (UTEVA) in the sample. The proposed developed method was shown to be more effective when enriched uranium (weapon grade) was added into the sample prior to the resin-based separation steps. In chapter 4, analysis of uranium isotope samples has usually been performed in a clean-room facility due to the presence of natural uranium in the environment that can potentially contaminate the sample. However, a clean room facility is not available in many laboratories that also carry out ICP analysis. There is also a lack in understanding of the potential contributors to natural uranium contamination, which can be identified through analysis of the process blanks. In this study, the process blanks were analysed in parallel to all samples to enable blank corrections to be performed for every step of the sample treatment processes. A significant portion of the natural uranium contamination was found to derive from reagents and consumables. The capability of analysis of different enrichment levels of uranium samples were evaluated by varying the amount of samples spiked during the sample preparation technique (lithium borate fusion) and assessed with the related relative uncertainties at the various mass point of spiked samples. The thesis ends with a concluding Chapter 5. ​Doctor of Philosophy (SPMS) 2018-03-19T04:38:41Z 2018-03-19T04:38:41Z 2018 Thesis Tiong, D. L. Y. (2018). Part I: Development of sample preparation method for analysis of total iodine in air filters. Part II: Application of Inductively coupled plasma-mass spectrometry in analysis of radionuclides-uranium and plutonium. Doctoral thesis, Nanyang Technological University, Singapore. http://hdl.handle.net/10356/73454 10.32657/10356/73454 en 119 p. application/pdf
spellingShingle DRNTU::Science::Chemistry
Tiong, Diane Ling Ying
Part I: Development of sample preparation method for analysis of total iodine in air filters. Part II: Application of Inductively coupled plasma-mass spectrometry in analysis of radionuclides-uranium and plutonium
title Part I: Development of sample preparation method for analysis of total iodine in air filters. Part II: Application of Inductively coupled plasma-mass spectrometry in analysis of radionuclides-uranium and plutonium
title_full Part I: Development of sample preparation method for analysis of total iodine in air filters. Part II: Application of Inductively coupled plasma-mass spectrometry in analysis of radionuclides-uranium and plutonium
title_fullStr Part I: Development of sample preparation method for analysis of total iodine in air filters. Part II: Application of Inductively coupled plasma-mass spectrometry in analysis of radionuclides-uranium and plutonium
title_full_unstemmed Part I: Development of sample preparation method for analysis of total iodine in air filters. Part II: Application of Inductively coupled plasma-mass spectrometry in analysis of radionuclides-uranium and plutonium
title_short Part I: Development of sample preparation method for analysis of total iodine in air filters. Part II: Application of Inductively coupled plasma-mass spectrometry in analysis of radionuclides-uranium and plutonium
title_sort part i development of sample preparation method for analysis of total iodine in air filters part ii application of inductively coupled plasma mass spectrometry in analysis of radionuclides uranium and plutonium
topic DRNTU::Science::Chemistry
url http://hdl.handle.net/10356/73454
work_keys_str_mv AT tiongdianelingying partidevelopmentofsamplepreparationmethodforanalysisoftotaliodineinairfilterspartiiapplicationofinductivelycoupledplasmamassspectrometryinanalysisofradionuclidesuraniumandplutonium