Design of optoacoustic imaging system for deep penetration medical diagnostics

The Photoacoustic effect has garnered large and widespread interests in recent years, especially in the field of biomedical systems and technology. Owing to its enhanced performance capabilities in contrast conventional optical or ultrasound imaging, photoacoustic (PA) imaging is a hybrid imaging mo...

Full description

Bibliographic Details
Main Author: Tan, Angus Xuan
Other Authors: Zheng Yuanjin
Format: Final Year Project (FYP)
Language:English
Published: 2018
Subjects:
Online Access:http://hdl.handle.net/10356/74478
_version_ 1811691634084020224
author Tan, Angus Xuan
author2 Zheng Yuanjin
author_facet Zheng Yuanjin
Tan, Angus Xuan
author_sort Tan, Angus Xuan
collection NTU
description The Photoacoustic effect has garnered large and widespread interests in recent years, especially in the field of biomedical systems and technology. Owing to its enhanced performance capabilities in contrast conventional optical or ultrasound imaging, photoacoustic (PA) imaging is a hybrid imaging modality that employs the use of the PA effect to obtain the desired result. It combines the ideal range and resolution property of optical and ultrasound imaging respectively, and the extent of its capabilities are still under deep research. A particular area of biomedical interest in recent years was using the photoacoustic effect to measure blood flow. This report introduced the usage of chirp technique in photoacoustic velocity and position measurement of blood and provided verification of the technique’s ability to improve the parameters of current PA blood flow measurement methods. The research methodology consists of information gathering and theory verification. The theory was subjected to a MATLAB simulation to confirm the viability, and subsequently an actual experiment was conducted. The results are compared with published research to evaluate the technique’s effectiveness. Experimental results have shown that the chirp technique is applicable in PA flowmetry and it had provided improved signal to noise ratio and spatial resolution. The results presented a usage of different technique in PA flowmetry and created opportunities of further improvements to the current technique. This will pave way for further in-depth research into the PA effect for biomedical applications.
first_indexed 2024-10-01T06:23:00Z
format Final Year Project (FYP)
id ntu-10356/74478
institution Nanyang Technological University
language English
last_indexed 2024-10-01T06:23:00Z
publishDate 2018
record_format dspace
spelling ntu-10356/744782019-12-10T11:57:53Z Design of optoacoustic imaging system for deep penetration medical diagnostics Tan, Angus Xuan Zheng Yuanjin School of Electrical and Electronic Engineering DRNTU::Engineering The Photoacoustic effect has garnered large and widespread interests in recent years, especially in the field of biomedical systems and technology. Owing to its enhanced performance capabilities in contrast conventional optical or ultrasound imaging, photoacoustic (PA) imaging is a hybrid imaging modality that employs the use of the PA effect to obtain the desired result. It combines the ideal range and resolution property of optical and ultrasound imaging respectively, and the extent of its capabilities are still under deep research. A particular area of biomedical interest in recent years was using the photoacoustic effect to measure blood flow. This report introduced the usage of chirp technique in photoacoustic velocity and position measurement of blood and provided verification of the technique’s ability to improve the parameters of current PA blood flow measurement methods. The research methodology consists of information gathering and theory verification. The theory was subjected to a MATLAB simulation to confirm the viability, and subsequently an actual experiment was conducted. The results are compared with published research to evaluate the technique’s effectiveness. Experimental results have shown that the chirp technique is applicable in PA flowmetry and it had provided improved signal to noise ratio and spatial resolution. The results presented a usage of different technique in PA flowmetry and created opportunities of further improvements to the current technique. This will pave way for further in-depth research into the PA effect for biomedical applications. Bachelor of Engineering 2018-05-18T06:13:38Z 2018-05-18T06:13:38Z 2018 Final Year Project (FYP) http://hdl.handle.net/10356/74478 en Nanyang Technological University 48 p. application/msword
spellingShingle DRNTU::Engineering
Tan, Angus Xuan
Design of optoacoustic imaging system for deep penetration medical diagnostics
title Design of optoacoustic imaging system for deep penetration medical diagnostics
title_full Design of optoacoustic imaging system for deep penetration medical diagnostics
title_fullStr Design of optoacoustic imaging system for deep penetration medical diagnostics
title_full_unstemmed Design of optoacoustic imaging system for deep penetration medical diagnostics
title_short Design of optoacoustic imaging system for deep penetration medical diagnostics
title_sort design of optoacoustic imaging system for deep penetration medical diagnostics
topic DRNTU::Engineering
url http://hdl.handle.net/10356/74478
work_keys_str_mv AT tanangusxuan designofoptoacousticimagingsystemfordeeppenetrationmedicaldiagnostics