Design of an under-frequency load shedding scheme in a micro-grid

The purpose of this study is to understand the relationship between the system frequency and the total synchronous generator loading and implement an under-frequency load shedding scheme to an existing load frequency control module. The behavior of the system depends on the amount of loading which w...

Full description

Bibliographic Details
Main Author: Vijayan, Navin
Other Authors: Foo Yi Shyh Eddy
Format: Final Year Project (FYP)
Language:English
Published: 2018
Subjects:
Online Access:http://hdl.handle.net/10356/74709
_version_ 1811683688946073600
author Vijayan, Navin
author2 Foo Yi Shyh Eddy
author_facet Foo Yi Shyh Eddy
Vijayan, Navin
author_sort Vijayan, Navin
collection NTU
description The purpose of this study is to understand the relationship between the system frequency and the total synchronous generator loading and implement an under-frequency load shedding scheme to an existing load frequency control module. The behavior of the system depends on the amount of loading which will then determine if the system frequency deviation is higher or lower than the nominal value of 50Hz. Load frequency control will not be applicable if the frequency deviation is too large. The under-frequency load shedding scheme is a control scheme whereby the loads are shed in several phases depending on the severity of the frequency deviation in the system.
first_indexed 2024-10-01T04:16:43Z
format Final Year Project (FYP)
id ntu-10356/74709
institution Nanyang Technological University
language English
last_indexed 2024-10-01T04:16:43Z
publishDate 2018
record_format dspace
spelling ntu-10356/747092023-07-07T16:32:51Z Design of an under-frequency load shedding scheme in a micro-grid Vijayan, Navin Foo Yi Shyh Eddy School of Electrical and Electronic Engineering DRNTU::Engineering The purpose of this study is to understand the relationship between the system frequency and the total synchronous generator loading and implement an under-frequency load shedding scheme to an existing load frequency control module. The behavior of the system depends on the amount of loading which will then determine if the system frequency deviation is higher or lower than the nominal value of 50Hz. Load frequency control will not be applicable if the frequency deviation is too large. The under-frequency load shedding scheme is a control scheme whereby the loads are shed in several phases depending on the severity of the frequency deviation in the system. Bachelor of Engineering 2018-05-23T04:42:04Z 2018-05-23T04:42:04Z 2018 Final Year Project (FYP) http://hdl.handle.net/10356/74709 en Nanyang Technological University 51 p. application/pdf
spellingShingle DRNTU::Engineering
Vijayan, Navin
Design of an under-frequency load shedding scheme in a micro-grid
title Design of an under-frequency load shedding scheme in a micro-grid
title_full Design of an under-frequency load shedding scheme in a micro-grid
title_fullStr Design of an under-frequency load shedding scheme in a micro-grid
title_full_unstemmed Design of an under-frequency load shedding scheme in a micro-grid
title_short Design of an under-frequency load shedding scheme in a micro-grid
title_sort design of an under frequency load shedding scheme in a micro grid
topic DRNTU::Engineering
url http://hdl.handle.net/10356/74709
work_keys_str_mv AT vijayannavin designofanunderfrequencyloadsheddingschemeinamicrogrid