Analysis of meniscal hoop strain in porcine knees

Menisci in human knee joints are two C-shaped cartilages which are predominantly made up of a network of collagen fibres. They play a very pivotal role in the biomechanics of the knee joint with their load bearing ability. As such, meniscal injuries or degeneration could lead to undesired consequenc...

Full description

Bibliographic Details
Main Author: Chu, Wei Fang
Other Authors: Chou Siaw Meng
Format: Final Year Project (FYP)
Language:English
Published: 2018
Subjects:
Online Access:http://hdl.handle.net/10356/75618
_version_ 1826119833074270208
author Chu, Wei Fang
author2 Chou Siaw Meng
author_facet Chou Siaw Meng
Chu, Wei Fang
author_sort Chu, Wei Fang
collection NTU
description Menisci in human knee joints are two C-shaped cartilages which are predominantly made up of a network of collagen fibres. They play a very pivotal role in the biomechanics of the knee joint with their load bearing ability. As such, meniscal injuries or degeneration could lead to undesired consequences such as arthritis of the knee joint. Injuries to the meniscus are usually treated with methods such as meniscectomy or meniscal repair. However, the effectiveness of the treatments being used may be undermined without a fundamental understanding of the meniscus mechanics. The hoop stress theory suggests that the load across a knee joint are distributed into the circumferential fibres in a meniscus resulting in hoop strains being generated. The objective of this study was to measure the hoop strain that was generated at the peripheral rim of the intact meniscus and with a 90% radial tear at flexion angles of 30° to 120°. This study serves to quantify the hoop strain values measured in a porcine meniscus and analyse this animal model since porcine knees are commonly used as a substitute for human knees in various studies. A total of 4 porcine knee joints were used for this study. The specimens were mounted onto a custom-designed fixture and was subjected to a compressive of 800 N in an Instron machine. The trend of the results showed that the medial posterior recorded a higher strain than the other regions. The strain recorded in the medial posterior meniscus side was also significantly higher than that recorded in the lateral posterior (P = 0.0002) and lateral anterior (P = 0.0059) of the intact meniscus. Results seemed to indicate that the strain of the medial anterior was lower than the strain measured in the medial posterior region of the intact meniscus. From this study, it seemed to suggest that there are different hoop strains measured in different regions of the meniscus under an axial load and the strain distribution is affected by meniscal tears.
first_indexed 2024-10-01T05:06:35Z
format Final Year Project (FYP)
id ntu-10356/75618
institution Nanyang Technological University
language English
last_indexed 2024-10-01T05:06:35Z
publishDate 2018
record_format dspace
spelling ntu-10356/756182023-03-04T18:35:56Z Analysis of meniscal hoop strain in porcine knees Chu, Wei Fang Chou Siaw Meng School of Mechanical and Aerospace Engineering DRNTU::Engineering::Mechanical engineering::Bio-mechatronics Menisci in human knee joints are two C-shaped cartilages which are predominantly made up of a network of collagen fibres. They play a very pivotal role in the biomechanics of the knee joint with their load bearing ability. As such, meniscal injuries or degeneration could lead to undesired consequences such as arthritis of the knee joint. Injuries to the meniscus are usually treated with methods such as meniscectomy or meniscal repair. However, the effectiveness of the treatments being used may be undermined without a fundamental understanding of the meniscus mechanics. The hoop stress theory suggests that the load across a knee joint are distributed into the circumferential fibres in a meniscus resulting in hoop strains being generated. The objective of this study was to measure the hoop strain that was generated at the peripheral rim of the intact meniscus and with a 90% radial tear at flexion angles of 30° to 120°. This study serves to quantify the hoop strain values measured in a porcine meniscus and analyse this animal model since porcine knees are commonly used as a substitute for human knees in various studies. A total of 4 porcine knee joints were used for this study. The specimens were mounted onto a custom-designed fixture and was subjected to a compressive of 800 N in an Instron machine. The trend of the results showed that the medial posterior recorded a higher strain than the other regions. The strain recorded in the medial posterior meniscus side was also significantly higher than that recorded in the lateral posterior (P = 0.0002) and lateral anterior (P = 0.0059) of the intact meniscus. Results seemed to indicate that the strain of the medial anterior was lower than the strain measured in the medial posterior region of the intact meniscus. From this study, it seemed to suggest that there are different hoop strains measured in different regions of the meniscus under an axial load and the strain distribution is affected by meniscal tears. Bachelor of Engineering (Mechanical Engineering) 2018-06-05T07:54:04Z 2018-06-05T07:54:04Z 2018 Final Year Project (FYP) http://hdl.handle.net/10356/75618 en Nanyang Technological University 78 p. application/pdf
spellingShingle DRNTU::Engineering::Mechanical engineering::Bio-mechatronics
Chu, Wei Fang
Analysis of meniscal hoop strain in porcine knees
title Analysis of meniscal hoop strain in porcine knees
title_full Analysis of meniscal hoop strain in porcine knees
title_fullStr Analysis of meniscal hoop strain in porcine knees
title_full_unstemmed Analysis of meniscal hoop strain in porcine knees
title_short Analysis of meniscal hoop strain in porcine knees
title_sort analysis of meniscal hoop strain in porcine knees
topic DRNTU::Engineering::Mechanical engineering::Bio-mechatronics
url http://hdl.handle.net/10356/75618
work_keys_str_mv AT chuweifang analysisofmeniscalhoopstraininporcineknees