Investigation of cooling efficiency of rim driven fans compared with conventional fans

Unlike most conventional fans, rim driven fans are not driven by an axisymmetric shaft but instead by the rim itself, thereby removing the need for a shaft. This is thus more effective and economical for the purposes of cooling for various appliances. A thorough steady CFD analysis was performed for...

Full description

Bibliographic Details
Main Author: Kanaparthi, Noel Anish
Other Authors: Basman Elhadidi
Format: Thesis
Language:English
Published: 2018
Subjects:
Online Access:http://hdl.handle.net/10356/75951
_version_ 1826111896059641856
author Kanaparthi, Noel Anish
author2 Basman Elhadidi
author_facet Basman Elhadidi
Kanaparthi, Noel Anish
author_sort Kanaparthi, Noel Anish
collection NTU
description Unlike most conventional fans, rim driven fans are not driven by an axisymmetric shaft but instead by the rim itself, thereby removing the need for a shaft. This is thus more effective and economical for the purposes of cooling for various appliances. A thorough steady CFD analysis was performed for this quantitative investigation, including a grid independence study for verification of both mesh models of both the rim driven fan as well as the conventional fan. Using a standard k-ro turbulence model on FL VENT™, the numerical results will reflect the intricate aspects of convective heat transfer in both models along with their flow visualization. A cooling efficiency parameter was formulated to compare the effective heat flux removed from the heat source by the respective fans thereby directly reflecting the aspect of cost.
first_indexed 2024-10-01T02:58:02Z
format Thesis
id ntu-10356/75951
institution Nanyang Technological University
language English
last_indexed 2024-10-01T02:58:02Z
publishDate 2018
record_format dspace
spelling ntu-10356/759512023-03-11T17:18:24Z Investigation of cooling efficiency of rim driven fans compared with conventional fans Kanaparthi, Noel Anish Basman Elhadidi School of Mechanical and Aerospace Engineering Technical University of Munich DRNTU::Engineering::Mechanical engineering Unlike most conventional fans, rim driven fans are not driven by an axisymmetric shaft but instead by the rim itself, thereby removing the need for a shaft. This is thus more effective and economical for the purposes of cooling for various appliances. A thorough steady CFD analysis was performed for this quantitative investigation, including a grid independence study for verification of both mesh models of both the rim driven fan as well as the conventional fan. Using a standard k-ro turbulence model on FL VENT™, the numerical results will reflect the intricate aspects of convective heat transfer in both models along with their flow visualization. A cooling efficiency parameter was formulated to compare the effective heat flux removed from the heat source by the respective fans thereby directly reflecting the aspect of cost. Master of Science (Aerospace Engineering) 2018-09-10T05:54:45Z 2018-09-10T05:54:45Z 2018 Thesis http://hdl.handle.net/10356/75951 en 47 p. application/pdf
spellingShingle DRNTU::Engineering::Mechanical engineering
Kanaparthi, Noel Anish
Investigation of cooling efficiency of rim driven fans compared with conventional fans
title Investigation of cooling efficiency of rim driven fans compared with conventional fans
title_full Investigation of cooling efficiency of rim driven fans compared with conventional fans
title_fullStr Investigation of cooling efficiency of rim driven fans compared with conventional fans
title_full_unstemmed Investigation of cooling efficiency of rim driven fans compared with conventional fans
title_short Investigation of cooling efficiency of rim driven fans compared with conventional fans
title_sort investigation of cooling efficiency of rim driven fans compared with conventional fans
topic DRNTU::Engineering::Mechanical engineering
url http://hdl.handle.net/10356/75951
work_keys_str_mv AT kanaparthinoelanish investigationofcoolingefficiencyofrimdrivenfanscomparedwithconventionalfans