Finite element analysis on femoral neck and intertrochanteric fractures

Hip fracture is one of the most commonly sustained fractures and the frequency is increasing with the aging population. Depending on the hip fracture location, it is classified into femoral neck fracture or intertrochanteric fracture. Therefore, the choice of implants needs to be selected appropriat...

Full description

Bibliographic Details
Main Author: Chng, Li Sing
Other Authors: Chou Siaw Meng
Format: Final Year Project (FYP)
Language:English
Published: 2019
Subjects:
Online Access:http://hdl.handle.net/10356/78793
_version_ 1811693800038334464
author Chng, Li Sing
author2 Chou Siaw Meng
author_facet Chou Siaw Meng
Chng, Li Sing
author_sort Chng, Li Sing
collection NTU
description Hip fracture is one of the most commonly sustained fractures and the frequency is increasing with the aging population. Depending on the hip fracture location, it is classified into femoral neck fracture or intertrochanteric fracture. Therefore, the choice of implants needs to be selected appropriately. Two set of finite element analysis studies were performed to validate the finite element model of the femoral neck and intertrochanteric fractures. In simulation A, Sawbone (model #3403) with Ø6.5 mm non cannulated screws were used. Osteoporotic material properties were applied to the cancellous and cortical bone. A two fragments of the femoral neck fracture were created based on the Pauwel’s classification angle of 60° and progressive axial loading was applied to the femoral head until failure. The maximum vertical reaction force and axial stiffness were 654.67 N and 621.2 N/mm respectively. In simulation B, Sawbone (model #3403) with proximal femoral nail anti rotation (PFNA) was used. Both osteoporotic and non-osteoporotic material properties were applied to the cancellous and cortical bone. A four fragments of intertrochanteric fracture were created based on the AO classification 31A2.2 and progressive axial loading was applied to the femoral head. The axial stiffness for osteoporotic femur with medial fragment at the baseline was 877.2 N/mm, which is in a good agreement with published literature. From the baseline of the medial fragment, a distal extension of 40 mm, 80 mm and 120 mm were created. Only the axial stiffness of the 40 mm distal extension were found to be significantly lower than the baseline.
first_indexed 2024-10-01T06:57:26Z
format Final Year Project (FYP)
id ntu-10356/78793
institution Nanyang Technological University
language English
last_indexed 2024-10-01T06:57:26Z
publishDate 2019
record_format dspace
spelling ntu-10356/787932023-03-04T18:46:45Z Finite element analysis on femoral neck and intertrochanteric fractures Chng, Li Sing Chou Siaw Meng School of Mechanical and Aerospace Engineering Engineering::Mechanical engineering Hip fracture is one of the most commonly sustained fractures and the frequency is increasing with the aging population. Depending on the hip fracture location, it is classified into femoral neck fracture or intertrochanteric fracture. Therefore, the choice of implants needs to be selected appropriately. Two set of finite element analysis studies were performed to validate the finite element model of the femoral neck and intertrochanteric fractures. In simulation A, Sawbone (model #3403) with Ø6.5 mm non cannulated screws were used. Osteoporotic material properties were applied to the cancellous and cortical bone. A two fragments of the femoral neck fracture were created based on the Pauwel’s classification angle of 60° and progressive axial loading was applied to the femoral head until failure. The maximum vertical reaction force and axial stiffness were 654.67 N and 621.2 N/mm respectively. In simulation B, Sawbone (model #3403) with proximal femoral nail anti rotation (PFNA) was used. Both osteoporotic and non-osteoporotic material properties were applied to the cancellous and cortical bone. A four fragments of intertrochanteric fracture were created based on the AO classification 31A2.2 and progressive axial loading was applied to the femoral head. The axial stiffness for osteoporotic femur with medial fragment at the baseline was 877.2 N/mm, which is in a good agreement with published literature. From the baseline of the medial fragment, a distal extension of 40 mm, 80 mm and 120 mm were created. Only the axial stiffness of the 40 mm distal extension were found to be significantly lower than the baseline. Bachelor of Engineering (Mechanical Engineering) 2019-06-28T01:36:34Z 2019-06-28T01:36:34Z 2019 Final Year Project (FYP) http://hdl.handle.net/10356/78793 en Nanyang Technological University 83 p. application/pdf
spellingShingle Engineering::Mechanical engineering
Chng, Li Sing
Finite element analysis on femoral neck and intertrochanteric fractures
title Finite element analysis on femoral neck and intertrochanteric fractures
title_full Finite element analysis on femoral neck and intertrochanteric fractures
title_fullStr Finite element analysis on femoral neck and intertrochanteric fractures
title_full_unstemmed Finite element analysis on femoral neck and intertrochanteric fractures
title_short Finite element analysis on femoral neck and intertrochanteric fractures
title_sort finite element analysis on femoral neck and intertrochanteric fractures
topic Engineering::Mechanical engineering
url http://hdl.handle.net/10356/78793
work_keys_str_mv AT chnglising finiteelementanalysisonfemoralneckandintertrochantericfractures