Particle Classification by the Tandem Differential Mobility Analyzer–Particle Mass Analyzer System

Particle mass analyzers, such as the aerosol particle mass analyzer (APM) and the Couette centrifugal particle mass analyzer (CPMA), are frequently combined with a differential mobility analyzer (DMA) to measure particle mass mp and effective density ρeff distributions of particles with a specific e...

Full description

Bibliographic Details
Main Author: Kuwata, Mikinori
Other Authors: Asian School of the Environment
Format: Journal Article
Language:English
Published: 2015
Online Access:https://hdl.handle.net/10356/79327
http://hdl.handle.net/10220/38824
_version_ 1826129234189352960
author Kuwata, Mikinori
author2 Asian School of the Environment
author_facet Asian School of the Environment
Kuwata, Mikinori
author_sort Kuwata, Mikinori
collection NTU
description Particle mass analyzers, such as the aerosol particle mass analyzer (APM) and the Couette centrifugal particle mass analyzer (CPMA), are frequently combined with a differential mobility analyzer (DMA) to measure particle mass mp and effective density ρeff distributions of particles with a specific electrical mobility diameter dm. Combinations of these instruments, which are referred to as the DMA–APM or DMA–CPMA system, are also used to quantify the mass-mobility exponent Dm of non-spherical particles as well as to eliminate multiple charged particles. This study investigates the transfer functions of these setups, focusing especially on the DMA–APM system. The transfer function of the DMA–APM system was derived by multiplying the transfer functions of DMA and APM. The APM transfer function can be calculated using either the uniform or parabolic flow models. The uniform flow model provides an analytical function, while the parabolic flow model is more accurate. The resulting DMA–APM transfer functions were plotted on log(mp)-log(dp) space. A theoretical analysis of the DMA–APM transfer function demonstrated that the resolution of the setup is maintained when the rotation speed ω of APM is scanned to measure distribution. In addition, an equation was derived to numerically calculate the minimum values of the APM resolution parameter λc for eliminating multiple charged particles.
first_indexed 2024-10-01T07:37:18Z
format Journal Article
id ntu-10356/79327
institution Nanyang Technological University
language English
last_indexed 2024-10-01T07:37:18Z
publishDate 2015
record_format dspace
spelling ntu-10356/793272020-09-26T21:36:20Z Particle Classification by the Tandem Differential Mobility Analyzer–Particle Mass Analyzer System Kuwata, Mikinori Asian School of the Environment Earth Observatory of Singapore Particle mass analyzers, such as the aerosol particle mass analyzer (APM) and the Couette centrifugal particle mass analyzer (CPMA), are frequently combined with a differential mobility analyzer (DMA) to measure particle mass mp and effective density ρeff distributions of particles with a specific electrical mobility diameter dm. Combinations of these instruments, which are referred to as the DMA–APM or DMA–CPMA system, are also used to quantify the mass-mobility exponent Dm of non-spherical particles as well as to eliminate multiple charged particles. This study investigates the transfer functions of these setups, focusing especially on the DMA–APM system. The transfer function of the DMA–APM system was derived by multiplying the transfer functions of DMA and APM. The APM transfer function can be calculated using either the uniform or parabolic flow models. The uniform flow model provides an analytical function, while the parabolic flow model is more accurate. The resulting DMA–APM transfer functions were plotted on log(mp)-log(dp) space. A theoretical analysis of the DMA–APM transfer function demonstrated that the resolution of the setup is maintained when the rotation speed ω of APM is scanned to measure distribution. In addition, an equation was derived to numerically calculate the minimum values of the APM resolution parameter λc for eliminating multiple charged particles. Accepted version 2015-10-21T08:08:56Z 2019-12-06T13:22:39Z 2015-10-21T08:08:56Z 2019-12-06T13:22:39Z 2015 2015 Journal Article Kuwata, M. (2015). Particle Classification by the Tandem Differential Mobility Analyzer–Particle Mass Analyzer System. Aerosol Science and Technology, 49(7), 508-520. https://hdl.handle.net/10356/79327 http://hdl.handle.net/10220/38824 10.1080/02786826.2015.1045058 en Aerosol Science and Technology © 2015 American Association for Aerosol Research. This is the author created version of a work that has been peer reviewed and accepted for publication in Aerosol Science and Technology, published by Taylor & Francis on behalf of American Association for Aerosol Research. It incorporates referee’s comments but changes resulting from the publishing process, such as copyediting, structural formatting, may not be reflected in this document.  The published version is available at: [http://dx.doi.org/10.1080/02786826.2015.1045058]. application/pdf application/pdf application/pdf
spellingShingle Kuwata, Mikinori
Particle Classification by the Tandem Differential Mobility Analyzer–Particle Mass Analyzer System
title Particle Classification by the Tandem Differential Mobility Analyzer–Particle Mass Analyzer System
title_full Particle Classification by the Tandem Differential Mobility Analyzer–Particle Mass Analyzer System
title_fullStr Particle Classification by the Tandem Differential Mobility Analyzer–Particle Mass Analyzer System
title_full_unstemmed Particle Classification by the Tandem Differential Mobility Analyzer–Particle Mass Analyzer System
title_short Particle Classification by the Tandem Differential Mobility Analyzer–Particle Mass Analyzer System
title_sort particle classification by the tandem differential mobility analyzer particle mass analyzer system
url https://hdl.handle.net/10356/79327
http://hdl.handle.net/10220/38824
work_keys_str_mv AT kuwatamikinori particleclassificationbythetandemdifferentialmobilityanalyzerparticlemassanalyzersystem