Dynamic Analysis of an Energy Efficiency Dehumidifier for Building Applications

This paper presents a dynamic analysis of an energy efficiency dehumidifier for building applications. This new structured dehumidifier is working with a controllable desiccant concentration, and the dynamic behavior of the heat and mass transfer process inside the dehumidifier becomes rather critic...

Full description

Bibliographic Details
Main Authors: Wu, Qiong, Wenjian, Cai, Suping, Shen, Haoren, Yon
Other Authors: School of Electrical and Electronic Engineering
Format: Conference Paper
Language:English
Published: 2017
Subjects:
Online Access:https://hdl.handle.net/10356/80356
http://hdl.handle.net/10220/42774
_version_ 1826112151715053568
author Wu, Qiong
Wenjian, Cai
Suping, Shen
Haoren, Yon
author2 School of Electrical and Electronic Engineering
author_facet School of Electrical and Electronic Engineering
Wu, Qiong
Wenjian, Cai
Suping, Shen
Haoren, Yon
author_sort Wu, Qiong
collection NTU
description This paper presents a dynamic analysis of an energy efficiency dehumidifier for building applications. This new structured dehumidifier is working with a controllable desiccant concentration, and the dynamic behavior of the heat and mass transfer process inside the dehumidifier becomes rather critical. A model is developed to describe the dynamic behavior of the process air with experimental validation. The numerical results of the dynamic response are clarified to conclude that decreasing the solution inlet temperature has a more significant impact on improving the dehumidification ability than increasing solution mass flow rate. The outcomes provide a comprehensive understanding of the dynamic behavior and the results will benefit the humidity control of the indoor air to improve the living quality of the occupants.
first_indexed 2024-10-01T03:02:15Z
format Conference Paper
id ntu-10356/80356
institution Nanyang Technological University
language English
last_indexed 2024-10-01T03:02:15Z
publishDate 2017
record_format dspace
spelling ntu-10356/803562022-07-22T06:28:38Z Dynamic Analysis of an Energy Efficiency Dehumidifier for Building Applications Wu, Qiong Wenjian, Cai Suping, Shen Haoren, Yon School of Electrical and Electronic Engineering Interdisciplinary Graduate School (IGS) Proceedings of the 2017 12th IEEE Conference on Industrial Electronics and Applications (ICIEA) Centre for System Intelligence and Efficiency (EXQUISITUS) Centre for E-City LDDS Dehumidifier This paper presents a dynamic analysis of an energy efficiency dehumidifier for building applications. This new structured dehumidifier is working with a controllable desiccant concentration, and the dynamic behavior of the heat and mass transfer process inside the dehumidifier becomes rather critical. A model is developed to describe the dynamic behavior of the process air with experimental validation. The numerical results of the dynamic response are clarified to conclude that decreasing the solution inlet temperature has a more significant impact on improving the dehumidification ability than increasing solution mass flow rate. The outcomes provide a comprehensive understanding of the dynamic behavior and the results will benefit the humidity control of the indoor air to improve the living quality of the occupants. NRF (Natl Research Foundation, S’pore) Accepted version 2017-06-29T07:56:33Z 2019-12-06T13:47:52Z 2017-06-29T07:56:33Z 2019-12-06T13:47:52Z 2017 Conference Paper Wu, Q., Cai, W., Shen, S., & You, H. (2017). Dynamic Analysis of an Energy Efficiency Dehumidifier for Building Applications. Proceedings of the 2017 12th IEEE Conference on Industrial Electronics and Applications (ICIEA). https://hdl.handle.net/10356/80356 http://hdl.handle.net/10220/42774 en © 2017 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works. 6 p. application/pdf
spellingShingle LDDS
Dehumidifier
Wu, Qiong
Wenjian, Cai
Suping, Shen
Haoren, Yon
Dynamic Analysis of an Energy Efficiency Dehumidifier for Building Applications
title Dynamic Analysis of an Energy Efficiency Dehumidifier for Building Applications
title_full Dynamic Analysis of an Energy Efficiency Dehumidifier for Building Applications
title_fullStr Dynamic Analysis of an Energy Efficiency Dehumidifier for Building Applications
title_full_unstemmed Dynamic Analysis of an Energy Efficiency Dehumidifier for Building Applications
title_short Dynamic Analysis of an Energy Efficiency Dehumidifier for Building Applications
title_sort dynamic analysis of an energy efficiency dehumidifier for building applications
topic LDDS
Dehumidifier
url https://hdl.handle.net/10356/80356
http://hdl.handle.net/10220/42774
work_keys_str_mv AT wuqiong dynamicanalysisofanenergyefficiencydehumidifierforbuildingapplications
AT wenjiancai dynamicanalysisofanenergyefficiencydehumidifierforbuildingapplications
AT supingshen dynamicanalysisofanenergyefficiencydehumidifierforbuildingapplications
AT haorenyon dynamicanalysisofanenergyefficiencydehumidifierforbuildingapplications