Online equivalent series resistance estimation method for condition monitoring of DC-link capacitors
In this paper, a cost-effective and reliable equivalent series resistance (ESR) estimation method for aluminium electrolytic capacitors used as DC-link capacitors in front-end rectifier fed inverters is proposed. The proposed method is based on the extraction of switching frequency components of DC-...
Main Authors: | , , , , , |
---|---|
Other Authors: | |
Format: | Conference Paper |
Language: | English |
Published: |
2018
|
Subjects: | |
Online Access: | https://hdl.handle.net/10356/88594 http://hdl.handle.net/10220/44698 |
_version_ | 1826119777804877824 |
---|---|
author | Sundararajan Prasanth Mohamed Halick Mohamed Sathik Firman Sasongko Tan, Chuan Seng Mohd Tariq Rejeki Simanjorang |
author2 | School of Electrical and Electronic Engineering |
author_facet | School of Electrical and Electronic Engineering Sundararajan Prasanth Mohamed Halick Mohamed Sathik Firman Sasongko Tan, Chuan Seng Mohd Tariq Rejeki Simanjorang |
author_sort | Sundararajan Prasanth |
collection | NTU |
description | In this paper, a cost-effective and reliable equivalent series resistance (ESR) estimation method for aluminium electrolytic capacitors used as DC-link capacitors in front-end rectifier fed inverters is proposed. The proposed method is based on the extraction of switching frequency components of DC-link voltage and current using band-pass filters. A limiting value of switching frequency is identified, below which a new solution is proposed to achieve higher accuracy compared to the similar methods using band-pass filters. The proposed method is verified by both simulation and experimental results and it is shown that the estimation error is very low so that this method can be used for condition monitoring of DC-link capacitors. |
first_indexed | 2024-10-01T05:05:40Z |
format | Conference Paper |
id | ntu-10356/88594 |
institution | Nanyang Technological University |
language | English |
last_indexed | 2024-10-01T05:05:40Z |
publishDate | 2018 |
record_format | dspace |
spelling | ntu-10356/885942020-03-07T13:24:45Z Online equivalent series resistance estimation method for condition monitoring of DC-link capacitors Sundararajan Prasanth Mohamed Halick Mohamed Sathik Firman Sasongko Tan, Chuan Seng Mohd Tariq Rejeki Simanjorang School of Electrical and Electronic Engineering 2017 IEEE Energy Conversion Congress and Exposition Rolls-Royce@NTU Corporate Lab Band-pass Filters ESR Estimation In this paper, a cost-effective and reliable equivalent series resistance (ESR) estimation method for aluminium electrolytic capacitors used as DC-link capacitors in front-end rectifier fed inverters is proposed. The proposed method is based on the extraction of switching frequency components of DC-link voltage and current using band-pass filters. A limiting value of switching frequency is identified, below which a new solution is proposed to achieve higher accuracy compared to the similar methods using band-pass filters. The proposed method is verified by both simulation and experimental results and it is shown that the estimation error is very low so that this method can be used for condition monitoring of DC-link capacitors. NRF (Natl Research Foundation, S’pore) Accepted version 2018-04-20T05:13:52Z 2019-12-06T17:06:50Z 2018-04-20T05:13:52Z 2019-12-06T17:06:50Z 2017-11-01 2017 Conference Paper Prasanth, S., Mohamed Sathik, M. H., Sasgonko, F., Tan, C. S., Mohd Tariq, & Simanjorang, R. (2017, October). Online equivalent series resistance estimation method for condition monitoring of DC-link capacitors. Paper presented at 2017 IEEE Energy Conversion Congress and Exposition, Cincinnati, OH, USA. https://hdl.handle.net/10356/88594 http://hdl.handle.net/10220/44698 10.1109/ECCE.2017.8096009 205869 en © 2017 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works. The published version is available at: [http://dx.doi.org/10.1109/ECCE.2017.8096009]. 8 p. application/pdf |
spellingShingle | Band-pass Filters ESR Estimation Sundararajan Prasanth Mohamed Halick Mohamed Sathik Firman Sasongko Tan, Chuan Seng Mohd Tariq Rejeki Simanjorang Online equivalent series resistance estimation method for condition monitoring of DC-link capacitors |
title | Online equivalent series resistance estimation method for condition monitoring of DC-link capacitors |
title_full | Online equivalent series resistance estimation method for condition monitoring of DC-link capacitors |
title_fullStr | Online equivalent series resistance estimation method for condition monitoring of DC-link capacitors |
title_full_unstemmed | Online equivalent series resistance estimation method for condition monitoring of DC-link capacitors |
title_short | Online equivalent series resistance estimation method for condition monitoring of DC-link capacitors |
title_sort | online equivalent series resistance estimation method for condition monitoring of dc link capacitors |
topic | Band-pass Filters ESR Estimation |
url | https://hdl.handle.net/10356/88594 http://hdl.handle.net/10220/44698 |
work_keys_str_mv | AT sundararajanprasanth onlineequivalentseriesresistanceestimationmethodforconditionmonitoringofdclinkcapacitors AT mohamedhalickmohamedsathik onlineequivalentseriesresistanceestimationmethodforconditionmonitoringofdclinkcapacitors AT firmansasongko onlineequivalentseriesresistanceestimationmethodforconditionmonitoringofdclinkcapacitors AT tanchuanseng onlineequivalentseriesresistanceestimationmethodforconditionmonitoringofdclinkcapacitors AT mohdtariq onlineequivalentseriesresistanceestimationmethodforconditionmonitoringofdclinkcapacitors AT rejekisimanjorang onlineequivalentseriesresistanceestimationmethodforconditionmonitoringofdclinkcapacitors |