Confining reinforcement for high strength concrete columns

A comprehensive parametric study of reinforced high-strength concrete (HSC) columns is undertaken to verify the current ACI 318 and NZS 3101 code provisions of confining reinforcement in the potential plastic hinge regions of HSC columns. A full range of parameters that have significan...

Full description

Bibliographic Details
Main Authors: Li, Bing., Park, R.
Other Authors: School of Civil and Environmental Engineering
Format: Journal Article
Language:English
Published: 2012
Subjects:
Online Access:https://hdl.handle.net/10356/95045
http://hdl.handle.net/10220/8398
http://www.concrete.org/PUBS/JOURNALS/OLJDetails.asp?Home=SJ&ID=13091
_version_ 1811689104646078464
author Li, Bing.
Park, R.
author2 School of Civil and Environmental Engineering
author_facet School of Civil and Environmental Engineering
Li, Bing.
Park, R.
author_sort Li, Bing.
collection NTU
description A comprehensive parametric study of reinforced high-strength concrete (HSC) columns is undertaken to verify the current ACI 318 and NZS 3101 code provisions of confining reinforcement in the potential plastic hinge regions of HSC columns. A full range of parameters that have significant influences on the available strength and curvature ductility factor in the potential plastic hinges of the columns during cyclic flexure are examined. These include the concrete compressive strength fc′ , the axial load level Pe/fc′ Ag, the yield strength of transverse reinforcement fyh, the volume ratio of the transverse reinforcement, the area ratio of the longitudinal reinforcement to the gross section area ρt, and the ratio of Ag/Ac. Previously derived stress-strain relationships for compressed HSC confined by various quantities, yield strengths, and arrangements of transverse reinforcement are used in cyclic moment-curvature analyses of a range of reinforced HSC columns to derive design equations. The proposed design equations are able to determine the quantities of transverse reinforcement required for the specified curvature ductility demands of HSC columns. The accuracy of the proposed design equations was checked by comparing with experimental data reported in previous literature, and a satisfactory correlation was found.
first_indexed 2024-10-01T05:42:48Z
format Journal Article
id ntu-10356/95045
institution Nanyang Technological University
language English
last_indexed 2024-10-01T05:42:48Z
publishDate 2012
record_format dspace
spelling ntu-10356/950452019-12-06T19:07:11Z Confining reinforcement for high strength concrete columns Li, Bing. Park, R. School of Civil and Environmental Engineering DRNTU::Engineering A comprehensive parametric study of reinforced high-strength concrete (HSC) columns is undertaken to verify the current ACI 318 and NZS 3101 code provisions of confining reinforcement in the potential plastic hinge regions of HSC columns. A full range of parameters that have significant influences on the available strength and curvature ductility factor in the potential plastic hinges of the columns during cyclic flexure are examined. These include the concrete compressive strength fc′ , the axial load level Pe/fc′ Ag, the yield strength of transverse reinforcement fyh, the volume ratio of the transverse reinforcement, the area ratio of the longitudinal reinforcement to the gross section area ρt, and the ratio of Ag/Ac. Previously derived stress-strain relationships for compressed HSC confined by various quantities, yield strengths, and arrangements of transverse reinforcement are used in cyclic moment-curvature analyses of a range of reinforced HSC columns to derive design equations. The proposed design equations are able to determine the quantities of transverse reinforcement required for the specified curvature ductility demands of HSC columns. The accuracy of the proposed design equations was checked by comparing with experimental data reported in previous literature, and a satisfactory correlation was found. Published version 2012-08-15T07:58:49Z 2019-12-06T19:07:11Z 2012-08-15T07:58:49Z 2019-12-06T19:07:11Z 2004 2004 Journal Article Li, B., & Park, R. Confining reinforcement for high strength concrete columns. ACI Structural Journal, 101(3), 314-324. https://hdl.handle.net/10356/95045 http://hdl.handle.net/10220/8398 http://www.concrete.org/PUBS/JOURNALS/OLJDetails.asp?Home=SJ&ID=13091 en ACI structural journal © 2004 American Concrete Institute. This paper was published in ACI structural journal and is made available as an electronic reprint (preprint) with permission of American Concrete Institute. The paper can be found at the following official URL: [http://www.concrete.org/PUBS/JOURNALS/OLJDetails.asp?Home=SJ&ID=13091]. One print or electronic copy may be made for personal use only. Systematic or multiple reproduction, distribution to multiple locations via electronic or other means, duplication of any material in this paper for a fee or for commercial purposes, or modification of the content of the paper is prohibited and is subject to penalties under law. application/pdf
spellingShingle DRNTU::Engineering
Li, Bing.
Park, R.
Confining reinforcement for high strength concrete columns
title Confining reinforcement for high strength concrete columns
title_full Confining reinforcement for high strength concrete columns
title_fullStr Confining reinforcement for high strength concrete columns
title_full_unstemmed Confining reinforcement for high strength concrete columns
title_short Confining reinforcement for high strength concrete columns
title_sort confining reinforcement for high strength concrete columns
topic DRNTU::Engineering
url https://hdl.handle.net/10356/95045
http://hdl.handle.net/10220/8398
http://www.concrete.org/PUBS/JOURNALS/OLJDetails.asp?Home=SJ&ID=13091
work_keys_str_mv AT libing confiningreinforcementforhighstrengthconcretecolumns
AT parkr confiningreinforcementforhighstrengthconcretecolumns