Comparing analytical, micromagnetic and statistical channel models at 4 Tcbpsi patterned media recording

Bit patterned media recording (BPMR) is a candidate technology proposed to extend the areal density growth capability of magnetic recording systems. In conventional granular magnetic recording (CGMR), bits of information are recorded onto a number of randomly distributed magnetic grains. The difficu...

Full description

Bibliographic Details
Main Authors: Cai, Kui, Elidrissi, Moulay Rachid, Eason, Kwaku, Chan, Kheong Sann, Goh, Wang Ling, Chua, M., Zhang, S. H., Qin, Z. L., Chai, K. S., Tan, K. P., Dong, Y., Victora, R. H.
Other Authors: School of Electrical and Electronic Engineering
Format: Journal Article
Language:English
Published: 2013
Subjects:
Online Access:https://hdl.handle.net/10356/96022
http://hdl.handle.net/10220/11422
_version_ 1824454502071140352
author Cai, Kui
Elidrissi, Moulay Rachid
Eason, Kwaku
Chan, Kheong Sann
Goh, Wang Ling
Chua, M.
Zhang, S. H.
Qin, Z. L.
Chai, K. S.
Tan, K. P.
Dong, Y.
Victora, R. H.
author2 School of Electrical and Electronic Engineering
author_facet School of Electrical and Electronic Engineering
Cai, Kui
Elidrissi, Moulay Rachid
Eason, Kwaku
Chan, Kheong Sann
Goh, Wang Ling
Chua, M.
Zhang, S. H.
Qin, Z. L.
Chai, K. S.
Tan, K. P.
Dong, Y.
Victora, R. H.
author_sort Cai, Kui
collection NTU
description Bit patterned media recording (BPMR) is a candidate technology proposed to extend the areal density growth capability of magnetic recording systems. In conventional granular magnetic recording (CGMR), bits of information are recorded onto a number of randomly distributed magnetic grains. The difficulty for the granular media approach is that due to the randomness of the grains, a certain minimum number of grains are required in order to maintain the media signal to noise ratio (SNR). This requires smaller grains as the bits are shrunk and we end up with either unstable, or unwriteable grains as per the well-known media-trilemma. In BPMR, instead of random positions, the "grains'' are ordered into a well-defined lattice of magnetic islands. Because of this ordering, the media SNR is no longer determined by the number of grains per bit as in CGMR, but is defined by the geometrical and magnetic distributions of the fabrication process of the media. Analytical models exist for BPMR, that flip grains in the media based on the switching field distribution (SFD) and the knowledge of the applied head field. On the other side, a statistical model for CGMR has been proposed that measures probabilities of grains flipping based on micromagnetic simulations, named the grain flipping probability (GFP) model. In this work, we adapt the GFP model for BPMR and perform a comparison between densities predicted via the analytical and GFP models, by processing the signals from these models with the appropriate detectors and LDPC (low density parity check) decoders.
first_indexed 2025-02-19T03:23:20Z
format Journal Article
id ntu-10356/96022
institution Nanyang Technological University
language English
last_indexed 2025-02-19T03:23:20Z
publishDate 2013
record_format dspace
spelling ntu-10356/960222020-03-07T13:57:22Z Comparing analytical, micromagnetic and statistical channel models at 4 Tcbpsi patterned media recording Cai, Kui Elidrissi, Moulay Rachid Eason, Kwaku Chan, Kheong Sann Goh, Wang Ling Chua, M. Zhang, S. H. Qin, Z. L. Chai, K. S. Tan, K. P. Dong, Y. Victora, R. H. School of Electrical and Electronic Engineering DRNTU::Engineering::Electrical and electronic engineering Bit patterned media recording (BPMR) is a candidate technology proposed to extend the areal density growth capability of magnetic recording systems. In conventional granular magnetic recording (CGMR), bits of information are recorded onto a number of randomly distributed magnetic grains. The difficulty for the granular media approach is that due to the randomness of the grains, a certain minimum number of grains are required in order to maintain the media signal to noise ratio (SNR). This requires smaller grains as the bits are shrunk and we end up with either unstable, or unwriteable grains as per the well-known media-trilemma. In BPMR, instead of random positions, the "grains'' are ordered into a well-defined lattice of magnetic islands. Because of this ordering, the media SNR is no longer determined by the number of grains per bit as in CGMR, but is defined by the geometrical and magnetic distributions of the fabrication process of the media. Analytical models exist for BPMR, that flip grains in the media based on the switching field distribution (SFD) and the knowledge of the applied head field. On the other side, a statistical model for CGMR has been proposed that measures probabilities of grains flipping based on micromagnetic simulations, named the grain flipping probability (GFP) model. In this work, we adapt the GFP model for BPMR and perform a comparison between densities predicted via the analytical and GFP models, by processing the signals from these models with the appropriate detectors and LDPC (low density parity check) decoders. 2013-07-15T06:32:45Z 2019-12-06T19:24:36Z 2013-07-15T06:32:45Z 2019-12-06T19:24:36Z 2012 2012 Journal Article Chua, M., Elidrissi, M. R., Eason, K., Zhang, S. H., Qin, Z. L., Chai, K. S., et al. (2012). Comparing analytical, micromagnetic and statistical channel models at 4 Tcbpsi patterned media recording. IEEE Transactions on Magnetics, 48(5), 1826-1832. https://hdl.handle.net/10356/96022 http://hdl.handle.net/10220/11422 10.1109/TMAG.2011.2169654 en IEEE transactions on magnetics © 2012 IEEE.
spellingShingle DRNTU::Engineering::Electrical and electronic engineering
Cai, Kui
Elidrissi, Moulay Rachid
Eason, Kwaku
Chan, Kheong Sann
Goh, Wang Ling
Chua, M.
Zhang, S. H.
Qin, Z. L.
Chai, K. S.
Tan, K. P.
Dong, Y.
Victora, R. H.
Comparing analytical, micromagnetic and statistical channel models at 4 Tcbpsi patterned media recording
title Comparing analytical, micromagnetic and statistical channel models at 4 Tcbpsi patterned media recording
title_full Comparing analytical, micromagnetic and statistical channel models at 4 Tcbpsi patterned media recording
title_fullStr Comparing analytical, micromagnetic and statistical channel models at 4 Tcbpsi patterned media recording
title_full_unstemmed Comparing analytical, micromagnetic and statistical channel models at 4 Tcbpsi patterned media recording
title_short Comparing analytical, micromagnetic and statistical channel models at 4 Tcbpsi patterned media recording
title_sort comparing analytical micromagnetic and statistical channel models at 4 tcbpsi patterned media recording
topic DRNTU::Engineering::Electrical and electronic engineering
url https://hdl.handle.net/10356/96022
http://hdl.handle.net/10220/11422
work_keys_str_mv AT caikui comparinganalyticalmicromagneticandstatisticalchannelmodelsat4tcbpsipatternedmediarecording
AT elidrissimoulayrachid comparinganalyticalmicromagneticandstatisticalchannelmodelsat4tcbpsipatternedmediarecording
AT easonkwaku comparinganalyticalmicromagneticandstatisticalchannelmodelsat4tcbpsipatternedmediarecording
AT chankheongsann comparinganalyticalmicromagneticandstatisticalchannelmodelsat4tcbpsipatternedmediarecording
AT gohwangling comparinganalyticalmicromagneticandstatisticalchannelmodelsat4tcbpsipatternedmediarecording
AT chuam comparinganalyticalmicromagneticandstatisticalchannelmodelsat4tcbpsipatternedmediarecording
AT zhangsh comparinganalyticalmicromagneticandstatisticalchannelmodelsat4tcbpsipatternedmediarecording
AT qinzl comparinganalyticalmicromagneticandstatisticalchannelmodelsat4tcbpsipatternedmediarecording
AT chaiks comparinganalyticalmicromagneticandstatisticalchannelmodelsat4tcbpsipatternedmediarecording
AT tankp comparinganalyticalmicromagneticandstatisticalchannelmodelsat4tcbpsipatternedmediarecording
AT dongy comparinganalyticalmicromagneticandstatisticalchannelmodelsat4tcbpsipatternedmediarecording
AT victorarh comparinganalyticalmicromagneticandstatisticalchannelmodelsat4tcbpsipatternedmediarecording