Analysis on micro-mixing enhancement through a constriction under time periodic electroosmotic flow

Numerical analyses of the recently proposed micro mixer based on periodic electroosmotic flow through a constriction were conducted. The validity and accuracy of the numerical model developed were verified experimentally. The model allows the prediction of operating parameters such as alternating cu...

Full description

Bibliographic Details
Main Authors: Lim, Chun Yee, Lam, Yee Cheong
Other Authors: School of Mechanical and Aerospace Engineering
Format: Journal Article
Language:English
Published: 2013
Subjects:
Online Access:https://hdl.handle.net/10356/96945
http://hdl.handle.net/10220/10192
_version_ 1826127157376581632
author Lim, Chun Yee
Lam, Yee Cheong
author2 School of Mechanical and Aerospace Engineering
author_facet School of Mechanical and Aerospace Engineering
Lim, Chun Yee
Lam, Yee Cheong
author_sort Lim, Chun Yee
collection NTU
description Numerical analyses of the recently proposed micro mixer based on periodic electroosmotic flow through a constriction were conducted. The validity and accuracy of the numerical model developed were verified experimentally. The model allows the prediction of operating parameters such as alternating current (AC) amplitude and frequency for optimum mixing. For accurate simulations of flow behavior such that optimum operating conditions could be determined, the electromigration effect of charged fluorescent dye added to the fluid stream must be considered. This effect, which is generally ignored, can be incorporated in the convection diffusion equation. Important factors that govern the mixing efficiency of the mixer, such as the contact area between the two fluids and the amplitude of fluid interface oscillation were quantified based on experimental and numerical results. Detailed error analyses were performed to investigate the sensitivity of simulation results to the variability of constriction width, diffusion coefficient, and fluorescein ion mobility. This also provides an understanding on the fabrication requirement for efficient mixing.
first_indexed 2024-10-01T07:04:11Z
format Journal Article
id ntu-10356/96945
institution Nanyang Technological University
language English
last_indexed 2024-10-01T07:04:11Z
publishDate 2013
record_format dspace
spelling ntu-10356/969452023-03-04T17:18:18Z Analysis on micro-mixing enhancement through a constriction under time periodic electroosmotic flow Lim, Chun Yee Lam, Yee Cheong School of Mechanical and Aerospace Engineering DRNTU::Engineering::Mechanical engineering Numerical analyses of the recently proposed micro mixer based on periodic electroosmotic flow through a constriction were conducted. The validity and accuracy of the numerical model developed were verified experimentally. The model allows the prediction of operating parameters such as alternating current (AC) amplitude and frequency for optimum mixing. For accurate simulations of flow behavior such that optimum operating conditions could be determined, the electromigration effect of charged fluorescent dye added to the fluid stream must be considered. This effect, which is generally ignored, can be incorporated in the convection diffusion equation. Important factors that govern the mixing efficiency of the mixer, such as the contact area between the two fluids and the amplitude of fluid interface oscillation were quantified based on experimental and numerical results. Detailed error analyses were performed to investigate the sensitivity of simulation results to the variability of constriction width, diffusion coefficient, and fluorescein ion mobility. This also provides an understanding on the fabrication requirement for efficient mixing. Accepted version 2013-06-11T07:02:15Z 2019-12-06T19:37:00Z 2013-06-11T07:02:15Z 2019-12-06T19:37:00Z 2011 2011 Journal Article Lim, C. Y., & Lam, Y. C. (2011). Analysis on micro-mixing enhancement through a constriction under time periodic electroosmotic flow. Microfluidics and Nanofluidics, 12(1-4), 127-141. 1613-4982 https://hdl.handle.net/10356/96945 http://hdl.handle.net/10220/10192 10.1007/s10404-011-0856-8 173613 en Microfluidics and nanofluidics © 2011 Springer-Verlag. This is the author created version of a work that has been peer reviewed and accepted for publication by Microfluidics and nanofluidics, Springer-Verlag. It incorporates referee’s comments but changes resulting from the publishing process, such as copyediting, structural formatting, may not be reflected in this document. The published version is available at: [DOI: http://dx.doi.org/10.1007/s10404-011-0856-8]. application/pdf
spellingShingle DRNTU::Engineering::Mechanical engineering
Lim, Chun Yee
Lam, Yee Cheong
Analysis on micro-mixing enhancement through a constriction under time periodic electroosmotic flow
title Analysis on micro-mixing enhancement through a constriction under time periodic electroosmotic flow
title_full Analysis on micro-mixing enhancement through a constriction under time periodic electroosmotic flow
title_fullStr Analysis on micro-mixing enhancement through a constriction under time periodic electroosmotic flow
title_full_unstemmed Analysis on micro-mixing enhancement through a constriction under time periodic electroosmotic flow
title_short Analysis on micro-mixing enhancement through a constriction under time periodic electroosmotic flow
title_sort analysis on micro mixing enhancement through a constriction under time periodic electroosmotic flow
topic DRNTU::Engineering::Mechanical engineering
url https://hdl.handle.net/10356/96945
http://hdl.handle.net/10220/10192
work_keys_str_mv AT limchunyee analysisonmicromixingenhancementthroughaconstrictionundertimeperiodicelectroosmoticflow
AT lamyeecheong analysisonmicromixingenhancementthroughaconstrictionundertimeperiodicelectroosmoticflow