Assessment of electromagnetic interference suppression performance of ferrite core loaded power cord

An evaluation methodology of the electromagnetic interference (EMI) suppression performance of a ferrite core clamped onto a power cord under its actual operating condition is proposed. With known electrical parameters of a ferrite core, the true EMI suppression performance of the ferrite core at a...

Full description

Bibliographic Details
Main Authors: Zhao, Y., Hu, B., See, Kye Yak, Tarateeraseth, Vuttipon
Other Authors: School of Electrical and Electronic Engineering
Format: Journal Article
Language:English
Published: 2013
Subjects:
Online Access:https://hdl.handle.net/10356/99400
http://hdl.handle.net/10220/17783
_version_ 1826129806606991360
author Zhao, Y.
Hu, B.
See, Kye Yak
Tarateeraseth, Vuttipon
author2 School of Electrical and Electronic Engineering
author_facet School of Electrical and Electronic Engineering
Zhao, Y.
Hu, B.
See, Kye Yak
Tarateeraseth, Vuttipon
author_sort Zhao, Y.
collection NTU
description An evaluation methodology of the electromagnetic interference (EMI) suppression performance of a ferrite core clamped onto a power cord under its actual operating condition is proposed. With known electrical parameters of a ferrite core, the true EMI suppression performance of the ferrite core at a specific location on a power cord under its intended operating condition can be determined. Based on a two-probe inductive coupling approach, the current probes are clamped on the power cord and the EMI attenuation of a ferrite core loaded power cord can be assessed more objectively without the actual operation interrupted. Taking into account the common-mode impedance of the ferrite core and the common-mode impedances of the power cord terminated with the intended source and load, the true EMI suppression performance of the ferrite core located at different positions along the power cord can be evaluated with confidence. The measured EMI suppression has also been validated with the simulation results using the transmission line model
first_indexed 2024-10-01T07:46:15Z
format Journal Article
id ntu-10356/99400
institution Nanyang Technological University
language English
last_indexed 2024-10-01T07:46:15Z
publishDate 2013
record_format dspace
spelling ntu-10356/994002020-03-07T14:02:44Z Assessment of electromagnetic interference suppression performance of ferrite core loaded power cord Zhao, Y. Hu, B. See, Kye Yak Tarateeraseth, Vuttipon School of Electrical and Electronic Engineering School of Electrical and Automation Engineering, Nanjing Normal University Dipartimento di Elettronica, Politecnico di Torino, Italy DRNTU::Engineering::Electrical and electronic engineering An evaluation methodology of the electromagnetic interference (EMI) suppression performance of a ferrite core clamped onto a power cord under its actual operating condition is proposed. With known electrical parameters of a ferrite core, the true EMI suppression performance of the ferrite core at a specific location on a power cord under its intended operating condition can be determined. Based on a two-probe inductive coupling approach, the current probes are clamped on the power cord and the EMI attenuation of a ferrite core loaded power cord can be assessed more objectively without the actual operation interrupted. Taking into account the common-mode impedance of the ferrite core and the common-mode impedances of the power cord terminated with the intended source and load, the true EMI suppression performance of the ferrite core located at different positions along the power cord can be evaluated with confidence. The measured EMI suppression has also been validated with the simulation results using the transmission line model 2013-11-19T05:13:12Z 2019-12-06T20:06:48Z 2013-11-19T05:13:12Z 2019-12-06T20:06:48Z 2010 2010 Journal Article Hu, B., Tarateeraseth, V., See, K. Y., & Zhao, Y. (2010). Assessment of electromagnetic interference suppression performance of ferrite core loaded power cord. IET Science, Measurement & Technology, 4(4), 229-236. https://hdl.handle.net/10356/99400 http://hdl.handle.net/10220/17783 10.1049/iet-smt.2009.0120 en IET science, measurement & technology © 2010 The Institution of Engineering and Technology. 8 p.
spellingShingle DRNTU::Engineering::Electrical and electronic engineering
Zhao, Y.
Hu, B.
See, Kye Yak
Tarateeraseth, Vuttipon
Assessment of electromagnetic interference suppression performance of ferrite core loaded power cord
title Assessment of electromagnetic interference suppression performance of ferrite core loaded power cord
title_full Assessment of electromagnetic interference suppression performance of ferrite core loaded power cord
title_fullStr Assessment of electromagnetic interference suppression performance of ferrite core loaded power cord
title_full_unstemmed Assessment of electromagnetic interference suppression performance of ferrite core loaded power cord
title_short Assessment of electromagnetic interference suppression performance of ferrite core loaded power cord
title_sort assessment of electromagnetic interference suppression performance of ferrite core loaded power cord
topic DRNTU::Engineering::Electrical and electronic engineering
url https://hdl.handle.net/10356/99400
http://hdl.handle.net/10220/17783
work_keys_str_mv AT zhaoy assessmentofelectromagneticinterferencesuppressionperformanceofferritecoreloadedpowercord
AT hub assessmentofelectromagneticinterferencesuppressionperformanceofferritecoreloadedpowercord
AT seekyeyak assessmentofelectromagneticinterferencesuppressionperformanceofferritecoreloadedpowercord
AT tarateerasethvuttipon assessmentofelectromagneticinterferencesuppressionperformanceofferritecoreloadedpowercord